Journals / Journal of the Turkish Chemical Society Section B: Chemical Engineering / 2017 / Özel Sayı 1

Effect of GLYMO/TEOS/MTEOS Sol-Gel Film Thickness on the Responses of Glucose Biosensor

Pages
17–24
Publication Date
2017-10-20
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In the present study, the effect of the film thickness on the responses of a glucose biosensor was investigated.
📊
Key Findings & Data:The sol-gel coating solutions were prepared by using (3-Glycidoxylpropyl) trimethoxysilane (GLYMO), tetraethoxysilane (TEOS), and methyltriethoxysilane (MTEOS).
💡
Conclusion & Impact:It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Biosensor · glucose · glucose oxidase

Abstract

In the present study, the effect of the film thickness on the responses of a glucose biosensor was investigated. The modified platinum electrodes used in the study were constructed by immobilization of glucose oxidase under a film layer of the sol-gel coating solution. The sol-gel coating solutions were prepared by using (3-Glycidoxylpropyl) trimethoxysilane (GLYMO), tetraethoxysilane (TEOS), and methyltriethoxysilane (MTEOS). Electrochemical measurements were carried out amperometrically by determining hydrogen peroxide released by the enzymatic reaction between glucose and glucose oxidase. It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme. It was determined that the film thickness has a significantly influence on the sensor responses. It was observed that the amperometric responses decreased by 85% when the volume of the coating solution dropped on the electrode increased from 4 µL to 12 µL.

🔖

Cite This Article

DEMİRKIRAN, N., EKİNCİ, E. (2017). Effect of GLYMO/TEOS/MTEOS Sol-Gel Film Thickness on the Responses of Glucose Biosensor. Journal of the Turkish Chemical Society Section B: Chemical Engineering, Özel Sayı 1, 17–24. https://ajindex.com/articles/681848

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Li J, Chia L.S., Goh N.K., Tan S.N., Ge H. Mediated amperometric glucose sensor modified by the sol-gel method, Sens Actuators B,1997
  2. DOI:10.1016/S0925-4005(97)80252-3 2. Chaubey A, Malhotra B.D. Mediated biosensors, Biosens Bioelectron, 2002
  3. DOI:10.1016/S0956-5663(01)00313-X 3. Freire R.S., Pessoa C.A., Mello L.D., Kubota L.T. Direct electron transfer:An approach for electrochemical biosensors with higher selectivity and sensitivity, J Braz Chem Soc, 2003
  4. http://jbcs.sbq.org.br/imageBank/PDF/v14n2a08.pdf 4. Wang J. Electrochemical glucose biosensors, Chem Rev, 2008
  5. DOI:10.1021/cr068123a 5. Collinson M.M. Analytical applications of organically modified silicates, Mikrochim Acta, 1998
  6. DOI:10.1007/BF01244737 6. Jin W, Brennan J.D., Properties and application of proteins encapsulated within sol-gel derived materials, Anal Chim Acta, 2002
  7. DOI:10.1016/S0003-2670(02)00229-5 7. Thenmozhi K, Narayanan S.S. Electrochemical sensor for H2O2 based on thionin immobilized 3-aminopropyltrimethoxy silane derived sol-gel thin film electrode, Sens Actuators B, 2007
  8. DOI:10.1016/j.snb.2007.02.006 8. Tu Y.F., Di J.W., Chen X.J. Study of the nano-size silica sol-gel film as the matrix of chemically modified electrode, J Sol-Gel Sci Technol, 2005
  9. DOI:10.1007/s10971-005-5613-6 9. Pandey P.C., Upadhyay S, Pathak, H.C. A new glucose sensor based on encapsulated glucose oxidase within organically modified sol-gel glass, Sens Actuators B, 1999
  10. DOI:10.1016/S0925-4005(99)00246-4 10. Pauliukaite R, Brett C.M.A. Characterization of novel glucose oxysilane sol-gel electrochemical biosensors with copper hexacynoferrate mediator, Electrochim Acta, 2005
  11. DOI:10.1016/j.electacta.2005.01.060 11. Demirkıran N, Ekinci E. Immobilization of glucose oxidase in GLYMO/MTEOS sol-gel film for glucose biosensor application, Acta Chim Slov, 2012
  12. http://acta-arhiv.chem-soc.si/59/59-2-302.pdf