Journals / Mühendis ve Makina / 2006 / Cilt: 47 - Sayı: 559

Hava kaynaklı ısı pompalarının soğuk iklim bölgelerinde kullanımı için önerilen tasarım ve modifikasyonlar

Pages
50–64
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Design and modification suggestions for air source heat pumps in cold climates are studied in this paper.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Use of air source heat pumps is limited in cold climates due to lower heating capacity and COP at lower ambient temperature conditions.
📊
Key Findings & Data:In addition, as ambient temperature decreases, heating cycle efficieny decreases due to higher temperature lift.
💡
Conclusion & Impact:Design and modification suggestions for air source heat pumps in cold climates are studied in this paper.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Use of air source heat pumps is limited in cold climates due to lower heating capacity and COP at lower ambient temperature conditions. Since cooling design loads are smaller than the heating design loads in cold climates, heat pumps are small sized for heating (backup heating required) or oversized for cooling. In addition, as ambient temperature decreases, heating cycle efficieny decreases due to higher temperature lift. To overcome such difficulties various design modifications and technologies have been suggested and applied. Design and modification suggestions for air source heat pumps in cold climates are studied in this paper.

Özet

Dış sıcaklıkların düşük olduğu zamanlarda elde edilen ısının ve COP'un düşük olması, hava kaynaklı ısı pompalarının soğuk iklim bölgelerinde kullanılmasını sınırlamaktadır. Soğuk İklimlerde soğutma dizayn yüklerinin ısıtma dizayn yüklerinden küçük olması sonucu ısı pompaları, ya ısıtma için küçük boyutlandırılmış (ilave ısıtma gerekli) veya soğutma için büyük boyutlandırılmış olur. Ayrıca, dış hava sıcaklığı azaldığında, kompresörde olan sıcaklık artışının yükselmesi nedeniyle ısıtma çevrimi verimi azalır. Bu güçlükleri ortadan kaldırmak amacıyla ısı pompaları için çeşitli dizayn modifikasyonları ve teknolojileri önerilmiş ve uygulanmıştır. Bu makalede, hava kaynaklı ısı pompalarının soğuk iklim bölgelerinde kullanımı için önerilen tasarım ve modifikasyonlar incelenmiştir.

🔖

Cite This Article

YILMAZ, M., ERDOĞAN, S., ÇOMAKLI, Ö., DURSUN, B. (2006). Hava kaynaklı ısı pompalarının soğuk iklim bölgelerinde kullanımı için önerilen tasarım ve modifikasyonlar. Mühendis ve Makina, Cilt: 47 - Sayı: 559, 50–64. https://ajindex.com/articles/289476

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Roth, K. W., Westphalen, D., Dieckmann, J., Hamilton, S.D., Goetzler, W.2002. Energy Consumption Characteristics of Commercial Building HVAC Systems Volume III: Energy Savings Potential. For BuildingTechnologies Program Project Manager: Dr. JamesBrodrick (DOE) Contract No.: DE-AC01-96CE23798 2.Saving Energy with Residential Heat Pumps in ColdClimates, CADDET (Center for the Analysis andDissemination of Demonstrated Energy Technologies),Maxi Brochure 08, ISBN 90-7 2647-37-8, 1997. 3. Cane, D. and Garnet, J.2000. Learning fromExperiences with Commercial/Institutional Heat PumpSystems in Cold Climates. CADDET Analyses Series No. 27,CADDET ENERGY Efficiency, ISBN-90-72647-46-7. 4.www.nyletherm.com Nyle Special Products, U.S.A., Cold Climate Heat Pump. 5. Minagawa, T. and Yamaguchi, Z.,1987. Operating Experience with Heat-Pump-Type Room Air Conditioners for Cold Districts. Proceedings of the 1987
  2. IEA Heat Pump Conference, Ed. By. Kay H. Zimmerman, 33-44. 6. Yamagami, K. M, Okada, Y., Maeno, M., Ito, A.,1998.Development of Burners For Room Air Conditioners (inJapanese). Tech Rev Mitsubishi Heavy Industries; 35:2. 7.Federal Technology Alert, 1999. Refrigerant Subcooling Technology for improving cooling systemperformance.http://www.eren.doe.gov/femp/. 8. Couvillion, R. J., Larson, M. V., Somerville, M.H.,1988.Analysis of a Vapor-compression Refrigeration System With Mechanical Subcooling. ASHRAE Transactions,94(2),641-660. 9. Miller, M.,1981. Mechanical Subcooling Yields Gains in Efficiency Capacity, Plus Lower Maintenance Costs. The Air-conditioning, Heating and Refrigeration News. 10. Unger, R.Z.,1998. Linear Compressors for Clean andSpeciality Gases. Proceedings of the 1998 InternationalCompressor Engineering Conference, Purdue University, West Lafayette, IN, 14-17. 11. Horiuchi N.1998. Development of Packaged Air Conditioner For Cold Regions in Japanese. Refrigeration 1997;72(837):7. "Development of Burner for Room Air Conditioner", 96-99,, (copy of partial English translation). 12. Cho, H., Chung, J.T., Kim, Y.2003. Influence of Liquid Refrigerant Injection on the Performance of an Inverter-driven scroll compressor. International Journal of Refrigeration 26 (2003) 8794. 13. Hirano T., Hagimoto K., Matsuda S. 1993. Study on Scrollcompressor Behavior in the Case of Liquid Refrigeration Injection. Transaction of Japanese Association of Refrigeration 10(2) 2738. 14. Dutta AK, Yanagisawa T, Fukuta M.,2001. An Investigation of the Performance of a Scroll Compr