Dergiler / Journal of Experimental and Clinical Medicine / 2013 / Cilt: 30 - Sayı: 4

Assessment of human thyroid function using radioimmunoassay and enzyme-linkedimmuno- sorbent-assay

Sayfa
317–321
Yayın Tarihi
2014-02-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Med., 2013; 30:317-321

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Thyroid function has been evaluated using Radioimmunoassay (RIA) and enzyme-linked-immuno-sorbent-assay (ELISA) techniques as a comparative study to determine the accuracy, sensitivity and specificity in addition to correlation with body mass index (BMI).
📊
Temel Bulgular & Veri:For triiodothyronine (T3) measured by RIA, relatively ELISA showed sensitivity, specificity and accuracy of 93.8%, 100% and 99.1% respectively and for thyroxin (T4), ELISA showed sensitivity, specificity and accuracy of 79.3%, 89.4% and 86.8% respectively.
💡
Sonuç & Katkı:Med., 2013; 30:317-321
🔬Tür:Araştırma Makalesi
📍Kapsam:2013 Verileri
⚙️Değişkenler:Radioimmunoassay · enzyme linked immunosorbent assay · thyroid

Abstract

Thyroid function has been evaluated using Radioimmunoassay (RIA) and enzyme-linked-immuno-sorbent-assay (ELISA) techniques as a comparative study to determine the accuracy, sensitivity and specificity in addition to correlation with body mass index (BMI). For triiodothyronine (T3) measured by RIA, relatively ELISA showed sensitivity, specificity and accuracy of 93.8%, 100% and 99.1% respectively and for thyroxin (T4), ELISA showed sensitivity, specificity and accuracy of 79.3%, 89.4% and 86.8% respectively. And for thyroid-stimulating hormone (TSH) ELISA showed a sensitivity, specificity and accuracy of 72.4%, 90.6% and 86% respectively and relative to RIA technique which is considered as standard goal. And for compensating the ELISA results to be same as RIA the following coefficient 0.72, 6.8 and 0.23 for T3, T4 and TSH respectively could be used. Also there is inverse linear relationship between the BMI and T3 and T4 using ELISA whereas the amount of T3 and T4 decreases by 0.006 nmol/kg/m2 and 0.051nmol/kg/m2 respectively. But TSH shows a direct linear relationship with BMI where TSH slightly increased by 0.007nmol/kg/m2. J. Exp. Clin. Med., 2013; 30:317-321

🔖

Bu Makaleye Atıf Yap

GAR-ELNAB, M. M., TAHA, R., ALİOMER, M., FARAHNA, M., BUSHARA, Y. M. (2014). Assessment of human thyroid function using radioimmunoassay and enzyme-linkedimmuno- sorbent-assay. Journal of Experimental and Clinical Medicine, Cilt: 30 - Sayı: 4, 317–321. https://ajindex.com/articles/678487

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Amballi, A.A., Dada, O.A., Adeleye, A.O., Salu, J., 2007. Evaluation of the determination of reference ranges for reproductive hormones (prolactin, FSH, LH, and testosterone) using enzyme immune assay method. Sci Res Essays. 2, 135-138.
  2. Baloch, Z., Carayon, P., Conte-Devolx, B., Demers, L.M., Feldt-Rasmussen, U., Henry, J.F., LiVosli, V.A., Niccoli-Sire, P., John, R., Ruf, J., Smyth, P.P., Spencer, C.A., Stockigt, J.R., 2003. Laboratory medicine practice guidelines: Laboratory support for the diagnosis and monitoring of thyroid disease. Thyroid. 13, 57-67.
  3. Benotti, J., Benotti, N., 1963. Protein-bound iodine, total iodine and butanol extractable iodine by partial automation. Clin. Chem, 9, 408-416.
  4. Brunilda Figueroa, Himilce Velez,Margarita Irizarry-Ramirez., 2008. Association of thyroid-stimulating hormone levels and body mass index in Overweight Hispanics in Puerto Rico. Ethn Dis, Vol. 18, 151-154.
  5. Figueroa, B., Velez, H, Irizarry-Ramirez, M., 2008. Association of thyroid-stimulating hormone levels and body mass index in Overweight Hispanics in Puerto Rico.Ethn Dis, 18, 151-154.
  6. Dayan, C. M., 2001. Interpretation of thyroid function tests. The Lancet. 357, 619-624.
  7. Dufour, D.R., 2007. Laboratory tests of thyroid function: Uses and limitations. Endocr. Metab. Clin. North Am. 36, 155-169.
  8. Gary, C., Althouse, James E. Hixon. 1999. Use of commercially available ELISAs to help determine estrous status in female swine. Swine Health and Prod. 7, 65-68.
  9. Hackney, A.C., Viru, A., 2008. Research methodology: Endocrinologic measurements in exercise science and sports medicine. J. Athl. Train. 43,631-639.
  10. Hoermann, R., Eckl, W., Hoermann, C., Larisch, R., 2010. Complex relationship between free thyroxine and TSH in the regulation of thyroid function. Eur J Endocrinol. 162, 1123-1129.
  11. Ingwersen, S.H., Jİrgensen, P.N., Eiskjaer, H., Johansen, N.L., Madsen, K., Faarup, P., 1992. Superiority of sandwich ELISA over competitive RIA for the estimation of ANP-270, an analogue of human atrial natriuretic factor. J Immunol Methods. 149, 237-246.
  12. Jostel, A., Ryder, W.D., Shalet, S. M., 2009. The use of thyroid function tests in the diagnosis of hypopituitarism: Definition and evaluation of the TSH Index. Clin. Endocrinol. 71, 529–534.
  13. Kahric-Janicic, N., Soldin, S.J, Soldin, O.P., West, T.G.J., Jonklaas, J., 2007. Tandem mass spectrometry improves the accuracy of free thyroxine measurements during pregnancy. Thyroid. 17, 303-311.
  14. Midgley, J. E. M., 2001. Direct and indirect fr