Can we trust the positivity of semi-quantitative glucose measurement in the urine?

Sayfa
161–164
Yayın Tarihi
2018-07-10
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The patient's concurrently measured HbA1c and fasting serum glucose results may be helpful to the laboratory specialist to avoid both false positives and false negatives.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: As known, when the blood glucose level exceeds the renal threshold value of 180-200 mg/dL begins to be excreted with urine.
📊
Temel Bulgular & Veri:Our aim in this study is to investigate the relationship between glucose levels in different sample types with simultaneous measurements.Material and Method: Simultaneous fasting serum glucose, HbA1c levels and urine glucose of 2375 patients were screened retrospectively from the hospital information system between June 1, 2015 and November 30, 2015.
💡
Sonuç & Katkı:The patient's concurrently measured HbA1c and fasting serum glucose results may be helpful to the laboratory specialist to avoid both false positives and false negatives.
🔬Tür:Araştırma Makalesi
📍Kapsam:2015 Verileri
⚙️Değişkenler:glucose · HbA1c · fasting serum glucose

Abstract

Objective: As known, when the blood glucose level exceeds the renal threshold value of 180-200 mg/dL begins to be excreted with urine. Spot urine analysis is easy to perform and an important test, with false positive or negative test results incompatible with the clinic. Our aim in this study is to investigate the relationship between glucose levels in different sample types with simultaneous measurements.Material and Method: Simultaneous fasting serum glucose, HbA1c levels and urine glucose of 2375 patients were screened retrospectively from the hospital information system between June 1, 2015 and November 30, 2015. Fasting serum glucose was measured by enzymatic hexokinase method in biochemical autoanalyzer, HbA1c was measured by chromatographic method on HPLC and urine glucose was measured semi-quantitatively by urine autoanalyzer by strip glucose oxidase method.Results: It was found that there was a medium-strong relationship between all three results. There was significant correlation between fasting serum glucose and HbA1c (r: 0.787, p <0.001) and the correlation between urinary glucose and fasting serum glucose and HbA1c were (r: 635, p <0.001) and (r: 533, p <0.001), respectively. Conclusion: In our study, we indicated that there is a strong correlation between the glucose results of different types of samples that we use in our laboratory. The patient's concurrently measured HbA1c and fasting serum glucose results may be helpful to the laboratory specialist to avoid both false positives and false negatives.

🔖

Bu Makaleye Atıf Yap

NAR, R., AVCİ, B. (2018). Can we trust the positivity of semi-quantitative glucose measurement in the urine?. Journal of Experimental and Clinical Medicine, Cilt: 34 - Sayı: 3, 161–164. https://ajindex.com/articles/678311

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Altınısık M. 2010. Biochemical Approach to Carbohydrate Metabolism Disorders. ADÜ Tıp Fakültesi Dergisi. 11, 51–59 American Diabetes Association. 2016. Classification and diagnosis of diabetes. In: 2016 Standards of Medical Care in Diabetes. Diabetes Care. 39, 13-22.
  2. Cersosimo E, Solis-Herrera C, Triplitt C. 2014. Inhibition of Renal Glucose Reabsorption as a Novel Treatment for Diabetes Patients. J Bras Nefrol. 36(1), 80–92
  3. Davies MJ, Williams DRR, Metcalf J, Day DL. 1993. Community screening for non-insulin-dependent diabetes mellitus: self testing for post-prandial glycosuria. Q J Med. 86, 677-684
  4. Englelgau MM, Narayan VKM, Herman WH. 2000. Screening for Type 2 diabetes. Diabetes Care. 23, 1563-1580.
  5. Friderichsen B, Maunsbach M. 1997. Glycosuric tests should not be employed in population screening. Journal of Public Health Medicine.19, 55-60.
  6. Herman WH, Fajans SS. 2010. Hemoglobin A1c for the diagnosis of diabetes: practical considerations. Pol Arch Med Wewn. 120, 37-40.
  7. Hillman N, Herranz L, Grande C, Vaquero PM, Pallardo LF. 2004. What is the relative contribution of blood glucose levels at different time points of the day to HbA1c in Type 1 diabetes? Diabet Med. 21, 468-470.
  8. Hu Y, Liu W, Chen Y, Zhang M, Wang L, Zhou H, Wu P, Teng X, Dong Y, Zhou Jw, Xu H, Zheng J, Li S, Tao T, Hu Y, Jia Y. 2010. Combined use of fasting plasma glucose and glycated hemoglobin A1c in the screening of diabetes and impaired glucose tolerance. Acta Diabetol. 47(3), 231-236.
  9. Karatoprak K, Uysal S, Akkılık ZS, Ercan M, Yılmaz FM. 2012. The Relationship Between Serum Biochemical Parameters And Glycaemic Control In Diabetes. Abant Med J. 1, 51-4
  10. Koenig RJ, Peterson CM, Kilo C, Cerami A, Williamson JR. 1976. Hemoglobin A1c as an indicator of the degree of glucose intolerance in diabetes. Diabetes. 25, 230-232.
  11. Lacher DA, Hughes JP, Carroll MD. 2005. Estimate of biological variation of laboratory analytes based on the Third National Health and Nutrition Examination Survey. Clin Chem. 51,450–452
  12. Mitchell R, Thomas SD, Langlois NE. 2013. How sensitive and specific is urinalysis ‘dipstick’ testing for detection of hyperglycaemia and ketosis? An audit of findings from coronial autopsies. Pathology. 45, 587-90
  13. Motor S, R Dokuyucu, F Sefil, MM Rifaioglu, Yengil E, Ulutas KT, Ahmet Taner Sümbül AT, Rızaoglu H, Ustun I, Gokce C. 2013. Relationship between Hba1c and blood glucose level in hemodialysis patients with diabetes mellitus. Dicle Medical Journal. 40 (4), 616-620
  14. Mundt L, Shana