Dergiler / Journal of Experimental and Clinical Medicine / 2026 / Volume: 31 Issue: 2

Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J

Sayfa
—
Yayın Tarihi
2014-09-10
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

This software can potentially be applied to measure other anatomical volumes from radiological images.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The aim of this study is to calculate the tympanic cavity (TC) volume with manual tracing technique on computed tomography images of temporal bone with a software developed in house using MATLAB platform.
📊
Temel Bulgular & Veri:Images with slice thickness of 0.25 mm were obtained from newborn cadavers and analyzed by two expert researchers independently using the software and the results were compared.
💡
Sonuç & Katkı:This software can potentially be applied to measure other anatomical volumes from radiological images.
🔬Tür:Article
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Computed tomography · image J · MATLAB

Abstract

The aim of this study is to calculate the tympanic cavity (TC) volume with manual tracing technique on computed tomography images of temporal bone with a software developed in house using MATLAB platform. Images with slice thickness of 0.25 mm were obtained from newborn cadavers and analyzed by two expert researchers independently using the software and the results were compared. The borders of TC were delineated manually and measurement of interested area was calculated on masked images. Then, the area measurements from all sections were added for the calculation of total volume. Dice similarity coefficient (DSC), Jaccard, sensitivity and specificity were used as a statistical validation metric to evaluate the performance of manual volume measurement. TC volumes were calculated as a 0.272±0.04 cm 3 and 0.286±0.03 cm 3 by the two researchers with MATLAB, 0.287±0.06 cm 3 with Image J. DSC values being above to 0.7 indicated that the software allows consistent and reliable volume measurements. This software can potentially be applied to measure other anatomical volumes from radiological images.

🔖

Bu Makaleye Atıf Yap

Acer, N., Unur, E., Sönmez, M. F., Zararsız, G., Arslan, A., Bilgen, M., Ertekin, T., Coşkun, A. (2014). Evaluation of tympanic cavity volume by using computed tomography scan with the MATLAB and image J. Journal of Experimental and Clinical Medicine, Volume: 31 Issue: 2. https://doi.org/10.5835/jecm.v2i31.5000068731

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...