Journals / Hittite Journal of Science and Engineering / 2019 / Cilt: 6 - Sayı: 2

Reduction Behavior of Moxifloxacin Hydrocholaride and Its Analysis in Spiked Human Urine and Dosage Form by Voltammetry

Pages
153–156
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Electroreduction mechanism was proposed

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A voltammetric method was developed to analyze moxifloxacin hydrochloride MoxHCl in pharmaceutical preparations and spiked human urine.
📊
Key Findings & Data:The experimental measurements were completed using different buffer systems pH 0.50- 12.05 on Glassy Carbon Electrode GCE with differential pulse voltammetry DPV and Cyclic Voltammetry CV methods.
💡
Conclusion & Impact:Electroreduction mechanism was proposed
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Moxifloxacin hydrochloride · Reduction · Pharmaceutical Preparations

Abstract

A voltammetric method was developed to analyze moxifloxacin hydrochloride MoxHCl in pharmaceutical preparations and spiked human urine. The experimental measurements were completed using different buffer systems pH 0.50- 12.05 on Glassy Carbon Electrode GCE with differential pulse voltammetry DPV and Cyclic Voltammetry CV methods. The effect of pH on the peak current and potential were determined. Britton-Robinson BR buffer pH 7.00 was used for analysis. The peak was established to be diffusion-controlled based on the nature of electrode. Calibration plots were prepared for the concentration range from 3×10-4 M to 1.1×10-3 M with DPV. Limits of detection LOD and quantification LOQ were calculated as 5.1×10-5 M and 2.30×10-4 M, respectively. The validation of the applied methods was completed. Electroreduction mechanism was proposed

🔖

Cite This Article

TEPELİ, B., YILMAZ, S., YAĞMUR, S. (2022). Reduction Behavior of Moxifloxacin Hydrocholaride and Its Analysis in Spiked Human Urine and Dosage Form by Voltammetry. Hittite Journal of Science and Engineering, Cilt: 6 - Sayı: 2, 153–156. https://ajindex.com/articles/537981

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Zhou Q, Long L, Liu L, Zhai H, Zhu M. Electrochemical determination of moxifloxacin hydrochloride based on molecularly imprinted polymer modified carbon paste electrode. Int. J. Electrochem. Sci. 10 (2015) 5069-5076
  2. Khan W, Sullivan KL, McCann JW, Gonsalves CF, Sato T. Moxifloxacin Prophylaxis for Chemoembolization or Embolization in Patients With Previous Biliary Interventions: A Pilot Study, AJR. Am J Roentgenol 197 (2011) 343-345
  3. Gyssens I.C, Dryden M, Kujath P, Nathwani D, Schaper N, Hampel B. J. Antimicrob Chemother 66 (2011) 2632-2642
  4. Xu YH, Li D, Liu XY, Li YZ, Lu J. Journal of Chromatography B 878 (2010) 3437-3341
  5. Hemanth A, Kumar K, Sudha V, Srinivasan R, Ramachandran G. Simple and rapid liquid chromatography method for determination of moxifloxacin in saliva. Journal of Chromatography B 879 (2011) 3663-3667
  6. Ulu S.T. Journal of Pharm. And Biomed. A. 43 (2007) 320-323
  7. Upadhyay SS, Kalambate PK, Srivastava AK. Enantioselective analysis of Moxifloxacin hydrochloride enantiomers with graphene-β-Cyclodextrin-nanocomposite modified carbon paste electrode using adsorptive stripping differential pulse voltammetry. Electrochimica Act. 248 (2017) 258-269
  8. Radi AE,Wahdan T, Anwar Z, Mostafa H. Electrochemical and spectroscopic studies on the Interaction of Gatifloxacin, Moxifloxacin and sparfloxacin with DNA and their analytical applications. Electroanalysis 22 (2010) 2665-2671
  9. Erk N. Voltammetric Behaviour And Determination Of Moxifloxacin In Pharmaceutical Products And Human Plasma. Anal Bioanal.Chem. 378 (2004) 1351-1356
  10. Long N, Zhu M, Yan Z. Anodic Adsorptive Voltammetric Determination of Moxifloxacin Hydrochloride. Physical Testing and Chemical Analysis (Part B: Chemical Analysis. R914;O657.14, 2012
  11. Trindade MAG, Da Silva GM, Ferreira VS. Interaction study of moxifloxacin with Cu(II) ion using square-wave voltammetry and its application in the determination in tablets. Microchemical Journal 81(2005) 209-216
  12. Abdel Ghani NT, El-Ries MA, El-Shall MA. Validated polarographic methods for the determination of certain antibacterial drugs. Analytical Sciences, 23 (2007) 1053-1058
  13. İnam R, Mercan H, Yılmaz E, Uslu B. Differential Pulse Polarographic Determination of Co(II) Using Moxifloxacine. Analytical Letters 40 (2007) 529-546
  14. Skrzypek S, Ciesielski W, Sokolowski A,Yılmaz S, Kazmiercak D. Square wave adsorptive stripping voltammetric determination of famotidine in urine. Talanta 66 (2005) 1146-1151. 1