Amaç & Hipotez:A voltammetric method was developed to analyze moxifloxacin hydrochloride MoxHCl in pharmaceutical preparations and spiked human urine.
📊
Temel Bulgular & Veri:The experimental measurements were completed using different buffer systems pH 0.50- 12.05 on Glassy Carbon Electrode GCE with differential pulse voltammetry DPV and Cyclic Voltammetry CV methods.
💡
Sonuç & Katkı:Electroreduction mechanism was proposed
A voltammetric method was developed to analyze moxifloxacin hydrochloride MoxHCl in pharmaceutical preparations and spiked human urine. The experimental measurements were completed using different buffer systems pH 0.50- 12.05 on Glassy Carbon Electrode GCE with differential pulse voltammetry DPV and Cyclic Voltammetry CV methods. The effect of pH on the peak current and potential were determined. Britton-Robinson BR buffer pH 7.00 was used for analysis. The peak was established to be diffusion-controlled based on the nature of electrode. Calibration plots were prepared for the concentration range from 3×10-4 M to 1.1×10-3 M with DPV. Limits of detection LOD and quantification LOQ were calculated as 5.1×10-5 M and 2.30×10-4 M, respectively. The validation of the applied methods was completed. Electroreduction mechanism was proposed
TEPELİ, B., YILMAZ, S., YAĞMUR, S. (2022). Reduction Behavior of Moxifloxacin Hydrocholaride and Its Analysis in Spiked Human Urine and Dosage Form by Voltammetry. Hittite Journal of Science and Engineering, Cilt: 6 - Sayı: 2, 153–156. https://ajindex.com/articles/537981
Zhou Q, Long L, Liu L, Zhai H, Zhu M. Electrochemical determination of moxifloxacin hydrochloride based on molecularly imprinted polymer modified carbon paste electrode. Int. J. Electrochem. Sci. 10 (2015) 5069-5076
Khan W, Sullivan KL, McCann JW, Gonsalves CF, Sato T. Moxifloxacin Prophylaxis for Chemoembolization or Embolization in Patients With Previous Biliary Interventions: A Pilot Study, AJR. Am J Roentgenol 197 (2011) 343-345
Gyssens I.C, Dryden M, Kujath P, Nathwani D, Schaper N, Hampel B. J. Antimicrob Chemother 66 (2011) 2632-2642
Xu YH, Li D, Liu XY, Li YZ, Lu J. Journal of Chromatography B 878 (2010) 3437-3341
Hemanth A, Kumar K, Sudha V, Srinivasan R, Ramachandran G. Simple and rapid liquid chromatography method for determination of moxifloxacin in saliva. Journal of Chromatography B 879 (2011) 3663-3667
Ulu S.T. Journal of Pharm. And Biomed. A. 43 (2007) 320-323
Upadhyay SS, Kalambate PK, Srivastava AK. Enantioselective analysis of Moxifloxacin hydrochloride enantiomers with graphene-β-Cyclodextrin-nanocomposite modified carbon paste electrode using adsorptive stripping differential pulse voltammetry. Electrochimica Act. 248 (2017) 258-269
Radi AE,Wahdan T, Anwar Z, Mostafa H. Electrochemical and spectroscopic studies on the Interaction of Gatifloxacin, Moxifloxacin and sparfloxacin with DNA and their analytical applications. Electroanalysis 22 (2010) 2665-2671
Erk N. Voltammetric Behaviour And Determination Of Moxifloxacin In Pharmaceutical Products And Human Plasma. Anal Bioanal.Chem. 378 (2004) 1351-1356
Long N, Zhu M, Yan Z. Anodic Adsorptive Voltammetric Determination of Moxifloxacin Hydrochloride. Physical Testing and Chemical Analysis (Part B: Chemical Analysis. R914;O657.14, 2012
Trindade MAG, Da Silva GM, Ferreira VS. Interaction study of moxifloxacin with Cu(II) ion using square-wave voltammetry and its application in the determination in tablets. Microchemical Journal 81(2005) 209-216
Abdel Ghani NT, El-Ries MA, El-Shall MA. Validated polarographic methods for the determination of certain antibacterial drugs. Analytical Sciences, 23 (2007) 1053-1058
İnam R, Mercan H, Yılmaz E, Uslu B. Differential Pulse Polarographic Determination of Co(II) Using Moxifloxacine. Analytical Letters 40 (2007) 529-546
Skrzypek S, Ciesielski W, Sokolowski A,Yılmaz S, Kazmiercak D. Square wave adsorptive stripping voltammetric determination of famotidine in urine. Talanta 66 (2005) 1146-1151. 1