It was observed that the organ dose varies with source strength and the duration of exposure whereas the effective dose to human body is linearly dependent upon the exposure time.
📌 3 Key Takeaways
🎯
Objective & Hypothesis:In the present investigation, Monte Carlo VMC code simulation was used for the estimation of individual organ dose and effective dose to human body using Cs-137, Co-60 and Na-24 radioactive external sources.
📊
Key Findings & Data:In the present investigation, Monte Carlo VMC code simulation was used for the estimation of individual organ dose and effective dose to human body using Cs-137, Co-60 and Na-24 radioactive external sources.
💡
Conclusion & Impact:It was observed that the organ dose varies with source strength and the duration of exposure whereas the effective dose to human body is linearly dependent upon the exposure time.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters
Abstract
In the present investigation, Monte Carlo VMC code simulation was used for the estimation of individual organ dose and effective dose to human body using Cs-137, Co-60 and Na-24 radioactive external sources. It was observed that the organ dose varies with source strength and the duration of exposure whereas the effective dose to human body is linearly dependent upon the exposure time.
Özet
Yapılan araştırmada, Cs-137, Co-60 ve Na-24 radyoaktif kaynaklarının harici kullanımında bireyselorgan dozunun ve insan vücuduna etkin dozun tahmini için Monte Carlo VMC kod simülasyonukullanılmıştır. Organ dozunun kaynak gücü ve maruz kalınan süre ile değiştiği gözlemlenirken, insanvücudunun etkin doza maruz kalma süresi ile lineer bağımlılığı bulunmuştur.
🔖
Cite This Article
KARA, Ü. (2022). Assessment of Different Body Organs Using Monte Carlo Simulation for Cs-137, Co-60 and Na-24. Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi, Cilt: 18 - Sayı: 2, 710–726. https://ajindex.com/articles/429964
Jacob, P. and Meckbach R., 1987. Shielding factors and externaldose evaluation. Radiation Protection Dosimetry, 21, 79–85.
Kis, Z., K. Eged, Voigt, R.M. and Müller,H.M., 2003. Guidelinesfor Planning Interventions Against External Exposure in Industrial Area after a Nuclear AccidentPart II: Calculation of Doses Using Monte Carlo method GSF Report,IAEA,34, 38. Meckbach, R.,Jacob P. and ParetzkeH.G., 1988. Gamma exposures due to radionuclides deposited in urban environments. Part I: kerma rates from contaminated urban surfaces. Radiation Protection Dosimetry, 25, 167–179.