Enerji korunumunda düşük enerjili bina tasarımları

Pages
26–32
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The temperature distribution in the wall thickness, time lag and decrement factor were given.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the thermal behaviour of brick wall construction without any insulation was investigated in the contex of Izmir's climatic condition.
📊
Key Findings & Data:The experimental set-up was composed of one insulated test chamber, which simulated the space room, with dimensions having 1,1 m* 1,2 m* 1,2 m and one wall to be tested and having 1,0 m*1,0 m surface area on each side.
💡
Conclusion & Impact:The temperature distribution in the wall thickness, time lag and decrement factor were given.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, the thermal behaviour of brick wall construction without any insulation was investigated in the contex of Izmir's climatic condition. The experiments were set up in atmospheric conditions. The experimental set-up was composed of one insulated test chamber, which simulated the space room, with dimensions having 1,1 m* 1,2 m* 1,2 m and one wall to be tested and having 1,0 m*1,0 m surface area on each side. In this experimental study, the total solar radiation incident on horizontal surface, the outdoor air temperature, the indoor air temperature, the outdoor and indoor surface temperatures, the temperatures of interfaces were measured continuously. The temperature distribution in the wall thickness, time lag and decrement factor were given.

Özet

Bu çalışmada, yalıtım içermeyen tuğla duvar kuruluşunun ısıl davranışı İzmir iklim koşullarında araştırılmıştır. Deneyler atmosferik koşullarda yapılmıştır. Deney düzeneği, boyutları 1,1 m* 1,2 m*1,2 m olan ve iç ortam koşullarının modellendiği yalıtımlı test odası ile yüzey alanı 1,0 m *1,0 m olan test duvarından oluşmuştur. Deneysel çalışmada yatay yüzeye gelen toplam güneş ışınımı, dış ve iç hava sıcaklıkları, iç ve dış yüzey sıcaklıkları ile ara yüzey sıcaklıkları sürekli olarak ölçülmüştür. Duvar içindeki sıcaklık dağılımı, zaman gecikmesi, sönüm oranı elde edilmiştir.

🔖