ARA YÜZ ÇÜRÜKLERİNİN TEŞHİSİNDE DIAGNOCAM CİHAZI İLE ELDE EDİLEN GÖRÜNTÜLERİN GÖZLEMCİLER ARASI TUTARLILIĞININ DEĞERLENDİRİLMESİ

EVALUATION OF THE CONSISTENCY OF IMAGES OBTAINED WITH THE DIAGNOCAM DEVICE BETWEEN DIFFERENT OBSERVERS IN THE DIAGNOSIS OF INTERFACE CARIES

Pages
75–79
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Veriler SPSS 20.0 yazılımı ile değerlendirilerek ağırlıklandırılmış kappa ve Fleiss kappa testleri kullanıldı.Bulgular: Gözlemciler arası uyumu gösteren Fleiss kappa değeri 0.76; gözlemci içi uyum değerleri ise 0.670 ile 0.749 arasında bulundu.Sonuç: DIAGNOcam görüntülerinin değerlendirilmesinde gözlemciler arası yüksek uyumun gözlendiği çalışmanın sonuçları, DIAGNO cam cihazının diş hekimi kliniklerinde yararlı olabileceğini düşündürmektedir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Kızılötesine yakın transilluminasyon sistemi, klinik ve radyografik olarak teşhis edilmesi zor olan interproksimal yüzeylerde diş çürüğünün erken tespitinde kullanılan yeni, iyonize olmayan bir görüntüleme yöntemidir.
📊
Key Findings & Data:Bu çalışmanın amacı, DIAGNOcam cihazı ile elde edilen görüntülerde, gözlemciler arası tutarlılığı belirleyerek, klinik çürük tanısının etkinliğini değerlendirmektir.Gereç ve Yöntem: Hacettepe Üniversitesi Diş Hekimliği Fakültesi Ağız, Diş ve Çene Radyolojisi Anabilim Dalı’na rutin muayene için başvurmuş, ara yüz çürüğünün değerlendirilmesi amacıyla bite-wing radyografisi alınan 18-80 yaş arası bireyler çalışmaya dahil edildi.
💡
Conclusion & Impact:Veriler SPSS 20.0 yazılımı ile değerlendirilerek ağırlıklandırılmış kappa ve Fleiss kappa testleri kullanıldı.Bulgular: Gözlemciler arası uyumu gösteren Fleiss kappa değeri 0.76; gözlemci içi uyum değerleri ise 0.670 ile 0.749 arasında bulundu.Sonuç: DIAGNOcam görüntülerinin değerlendirilmesinde gözlemciler arası yüksek uyumun gözlendiği çalışmanın sonuçları, DIAGNO cam cihazının diş hekimi kliniklerinde yararlı olabileceğini düşündürmektedir.
🔬Design:Experimental Field Trial
📍Scope:274 adet
⚙️Variables:Domain Parameters

Abstract

Amaç: Kızılötesine yakın transilluminasyon sistemi, klinik ve radyografik olarak teşhis edilmesi zor olan interproksimal yüzeylerde diş çürüğünün erken tespitinde kullanılan yeni, iyonize olmayan bir görüntüleme yöntemidir. Bu çalışmanın amacı, DIAGNOcam cihazı ile elde edilen görüntülerde, gözlemciler arası tutarlılığı belirleyerek, klinik çürük tanısının etkinliğini değerlendirmektir.Gereç ve Yöntem: Hacettepe Üniversitesi Diş Hekimliği Fakültesi Ağız, Diş ve Çene Radyolojisi Anabilim Dalı’na rutin muayene için başvurmuş, ara yüz çürüğünün değerlendirilmesi amacıyla bite-wing radyografisi alınan 18-80 yaş arası bireyler çalışmaya dahil edildi. Başlangıç çürüğü olan veya olmayan 274 adet dişin görüntüleri DIAGNO cam cihazı ile elde edildi. Görüntüler, üç deneyimli radyolog tarafından ayrı ayrı değerlendirildi. Veriler SPSS 20.0 yazılımı ile değerlendirilerek ağırlıklandırılmış kappa ve Fleiss kappa testleri kullanıldı.Bulgular: Gözlemciler arası uyumu gösteren Fleiss kappa değeri 0.76; gözlemci içi uyum değerleri ise 0.670 ile 0.749 arasında bulundu.Sonuç: DIAGNOcam görüntülerinin değerlendirilmesinde gözlemciler arası yüksek uyumun gözlendiği çalışmanın sonuçları, DIAGNO cam cihazının diş hekimi kliniklerinde yararlı olabileceğini düşündürmektedir.

Özet

Background and Aim: Near-infrared transillumination system is a novel non-ionizing imaging method which is used in the detection of early caries lesions at interproximal surfaces that are difficult to diagnose clinically and radiographically. The aim of this study was to evaluate the effectiveness of clinical diagnosis of caries diagnosis by determining the consistency between different observers from images obtained with the DIAGNOcam device operating with this system.Materials and Methods: In the present study, patients admitted to the Department of Dentomaxillofacial Radiology of, Faculty of Dentistry, for routine examination in the age range 18–80 years and who had bite-wing radiographs for the detection of approximal caries were included. Images of 274 teeth with or without initial caries were obtained with the DIAGNOcam device. The obtained images were separately evaluated by three experienced radiologists. The data were evaluated using SPSS 20.0 software; weighted kappa and Fleiss kappa tests were used.Results: The Fleiss kappa value was 0.76, showing the inter-observer agreement; the intra-observer agreement values were between 0.670 and 0.749.Conclusion: The high inter-observer consistency level obtained in the evaluation of DIAGNOcam images in this study suggests that the DIAGNOcam device may be useful in dental practice.

🔖

Cite This Article

ÖZATEŞ, Z., KOÇ, N., DOĞRU, H. B., ÇAMLIBEL, Y., ÇİÇEK, S., ÇİÇEK, S., TEKİN, K. B., KARABULUT, E., ÖZBEK, Ş. M. (2020). ARA YÜZ ÇÜRÜKLERİNİN TEŞHİSİNDE DIAGNOCAM CİHAZI İLE ELDE EDİLEN GÖRÜNTÜLERİN GÖZLEMCİLER ARASI TUTARLILIĞININ DEĞERLENDİRİLMESİ. Clinical Dentistry and Research, Cilt: 44 - Sayı: 3, 75–79. https://ajindex.com/articles/178181

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Abogazalah N, Eckert GJ, Ando M. In vitro performance of near infrared light transillumination at 780-nm and digital radiography for detection of non-cavitated approximal caries. J Dent 2017; 63: 44-50
  2. Schaefer G, Pitchika V, Litzenburger F, Hickel R, Kuhnisch J. Evaluation of occlusal caries detection and assessment by visual inspection, digital bitewing radiography and near-infrared light transillumination. Clin Oral Investig 2018; 22: 2431-2438
  3. Kuhnisch J, Sochtig F, Pitchika V, Laubender R, Neuhaus KW, Lussi A et al. In vivo validation of near-infrared light transillumination for interproximal dentin caries detection. Clin Oral Investig 2016; 20: 821-829
  4. Błażejewska A, Dacyna N, Niesiobędzki P, Trzaska M, Gozdowski D, Turska-Szybka A et al. Comparison of the Detection of Proximal Caries in Children and Youth Using DIAGNOcam and Bitewing Radiovisiography. Dent Med Probl 2016; 53: 468-475
  5. Marinova-Takorova M, Anastasova R, Panov VE. Comparative evaluation of the effectiveness of five methods for early diagnosis of occlusal caries lesions–in vitro study. J of IMAB 2014; 20: 533- 536
  6. Litzenburger F, Heck K, Pitchika V, Neuhaus KW, Jost FN, Hickel R et al. Inter-and intraexaminer reliability of bitewing radiography and near-infrared light transillumination for proximal caries detection and assessment. Dentomaxillofac Radiol 2018; 47: 20170292
  7. Abdelaziz M, Krejci IJIJED. DIAGNOcam--a near infrared digital imaging Transillumination (NIDIT) technology. Int J Esthet Dent 2015; 10: 158-165
  8. Al Shaya SA, Saeed MH, Kheder WMJJoID, Research M. Proximal Caries Detection in Permanent Teeth by Using DIAGNOcam: An in Vivo Study. J. Int Dent Medical Res 2018; 11: 45-50
  9. Önem E, Baksi B, Şen B, Söğüt Ö, Mert A. Diagnostic accuracy of proximal enamel subsurface demineralization and its relationship with calcium loss and lesion depth. Dentomaxillofac Radiol 2012; 41: 285-293
  10. Ozkan G, Guzel KGU. Clinical evaluation of near-infrared light transillumination in approximal dentin caries detection. Lasers Med Sci 2017; 32: 1417–1422
  11. Eliasz W, Raczkowski M, Surdacka AJJDF. Caries Detection with DIAGNOCam: A Review. J DentForecast 2018; 1: 1009
  12. Lee RC, Darling CL, Staninec M, Ragadio A, Fried D. Activity assessment of root caries lesions with thermal and near-IR imaging methods. J Biophotonics 2017; 10: 433-445
  13. Almaz EC, Simon JC, Fried D, Darling CL. Influence of stains on lesion contrast in the pits and fissures of tooth occlu