Journals / Türk Fen ve Sağlık Dergisi / 2020 / Cilt: 1 Sayı: 2

The use of potentiometric sensors in wastewater analysis

Atık Su Analizlerinde Potansiyometrik Sensörlerin Kullanımı

Oğuz Özbek(ZONGULDAK BÜLENT ECEVİT ÜNİVERSİTESİ)0000-0001-5185-9681
Ömer Işıldak(TOKAT GAZİOSMANPAŞA ÜNİVERSİTESİ)0000-0003-4690-4323
Kamil Mert Yiğit(TOKAT GAZİOSMANPAŞA ÜNİVERSİTESİ)0000-0002-1123-7586
Alper Çetin(TOKAT GAZİOSMANPAŞA ÜNİVERSİTESİ)
Pages
70–78
Publication Date
2020-06-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this review, we investigated potentiometric sensor studies which have been successfully applied to the developed wastewater samples.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Domestic and industrial water pollution is a serious environmental problem.
📊
Key Findings & Data:Because metal ions are used in industrial processes such as mining, metal coating, electroplating, medicine and battery production, many metals and heavy metals can cause industrial water pollution.
💡
Conclusion & Impact:In this review, we investigated potentiometric sensor studies which have been successfully applied to the developed wastewater samples.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Potansiyometri · sensör · atık su analizi

Abstract

Domestic and industrial water pollution is a serious environmental problem. Because metal ions are used in industrial processes such as mining, metal coating, electroplating, medicine and battery production, many metals and heavy metals can cause industrial water pollution. Generally, the determination of these metals is made by instrumental devices. Potentiometric ion selective sensors have been extensively studied by analytical chemists for many years due to their advantages. The developed potentiometric sensors have been used successfully in environmental sample analysis and different sensors have been developed till today and introduced into the literature. In this review, we investigated potentiometric sensor studies which have been successfully applied to the developed wastewater samples.

Özet

Evsel ve endüstriyel su kirliliği ciddi bir çevre sorunudur. Metal iyonları madencilik, metal kaplama, elektrokaplama, ilaç ve pil üretimi gibi endüstriyel işlemlerde kullanıldığından dolayı, birçok metal ve ağır metal endüstriyel su kirliliğine neden olabilir. Genel olarak, bu metallerin tayini enstrümantal cihazlar tarafından yapılır. Potansiyometrik iyon seçici sensörler, avantajları nedeniyle analitik kimyagerler tarafından uzun yıllardır kapsamlı bir şekilde araştırılmaktadır. Geliştirilen potansiyometrik sensörler çevresel örneklerin analizinde başarıyla kullanılmış ve günümüze kadar farklı sensörler geliştirilerek, literatüre sunulmuştur. Bu derlemede, atık su örneklerine başarıyla uygulanan potansiyometrik sensör çalışmaları araştırılmıştır.

🔖

Cite This Article

Özbek, O., Işıldak, Ö., Yiğit, K. M., Çetin, A. (2020). The use of potentiometric sensors in wastewater analysis. Türk Fen ve Sağlık Dergisi, Cilt: 1 Sayı: 2, 70–78. https://ajindex.com/articles/1560396

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (33)

  1. Afkhami, A., Khoshsafar, H., Madrakian, T., Shirzadmehr, A. (2014). A new nano-composite electrode as a copper (II) selective potentiometric sensor. Journal of the Iranian Chemical Society, 11, 1373-1380. https://doi.org/10.1007/s13738-014-0406-x
  2. Badakhshan, S., Ahmadzadeh, S., Mohseni‑Bandpei, A., Aghasi, M., Basiri, A. (2019).Potentiometric sensor for iron (III) quantitative determination: experimental and computational approaches. BMC Chemistry, 13, 131. https://doi.org/10.1186/s13065-019-0648-x
  3. Bagheri, H., Afkhami, A., Shirzadmehr, A., Khoshsafar, H., Khoshsafar, H., Ghaedi, H. (2013). Novel potentiometric sensor for the determination of Cd2Y based on a new nano-composite. International Journal of Environmental Analytical Chemistry, 93(5), 578-591. http://dx.doi.org/10.1080/03067319.2011.649741
  4. Canpolat, Ö ve Uzun S. (2019). Kahramanmaraş Organize Sanayi Bölgesi Atık Sularının Sır Baraj Gölü’nde Meydana Getirdiği Ağır Metal Kirliliğinin Belirlenmesi. BEÜ Fen Bilimleri Dergisi, 8 (3), 816-825. https://doi.org/10.17798/bitlisfen.535940
  5. Cunha, C. O., Silva, R. C. R., Amorim, C. G., Jfflnior, S. A., Araffljo, A. N., Montenegro, M. C. B. S. M., Silva, V. L. (2010). Tetracycline Potentiometric Sensor Based on Cyclodextrin for Pharmaceuticals and Waste Water Analysis. Electroanalysis, 22(24), 2967-2972. https://doi.org/10.1002/elan.201000301
  6. Dündar, M. Ş., Altundağ, H., Kaygaldurak S., Şar, V., Acar, A. (2012). Çeşitli Endüstriyel Atık Sularda Ağır Metal Düzeylerinin Belirlenmesi. SAÜ Fen Bilimleri Dergisi, 16(1), 6-12.
  7. Ensafi, A. A., Meghdadi, S., Sedighi, S. (2009). Sensitive cadmium potentiometric sensor based on 4-hydroxy salophen as a fast tool for water samples analysis. Desalination, 242(1-3), 336-345. https://doi.org/10.1016/j.desal.2008.06.002
  8. Frag, E. Y. Z., Aglan, R. F., Mohamed, H. A. (2016). Lanthanum(III) potentiometric sensors based on ethyl benzoyl acetate. Arabian Journal of Chemistry, 12, 388–397. http://dx.doi.org/10.1016/j.arabjc.2016.11.015
  9. Ganjali, M. R., Faridbod, F., Davarkhah, N., Shahtaheri, S. J., Norouzi, P. (2015). All Solid State Graphene Based Potentiometric Sensors forMonitoring of Mercury Ions inWasteWater Samples. International Journal of Environmental Research, 9(1), 333-340. https://doi.org/10.22059/IJER.2015.905
  10. Ganjali, M. R., Mizani, F., Salavati-Niasari, M., Javanbakht, M. (2003). Novel potentiometric membrane sensor for the determination of trace amounts of chromium(III) ions. Analytical Sciences, 19(2), 235- 238. https://doi.org/10.2116/analsci.19.235
  11. Gupta, V. V., Jain, A. K., Al Khayat, M., Bhargavac, S. K., Raisoni, J. R. (2008). Electroanalytical studies on cobalt(II) selective potentiometric sensor based on bridge modified calixarene in poly(vinyl chloride). Electrochimica Acta, 53, 5409-5414. https://doi.org/10.1016/j.electacta.2008.02.085
  12. Gupta, V. K., Jain, A. K., Maheshwari G. (2007).Synthesis, Characterization and Pb(II) Ion Selectivity of N, N´-bis(2-hydroxy-1-napthalene)-2,6-pyridiamine (BHNPD). International Journal of Electrochemical Science, 2, 102-112.
  13. Isildak, Ö., Özbek, O., Yigit, K. M. (2019). Zinc(II)-selective PVC membrane potentiometric sensor for analysis of Zn2+ in drug sample and different environmental samples. International Journal of Environmental Analytical Chemistry, 1-11. https://doi.org/10.1080/03067319.2019.1691542
  14. Isildak, O., Deligönül, N., Ozbek, O. (2019). A novel silver(I)-selective PVC membrane sensor and its potentiometric applications. Turkish Journal of Chemistry, 43, 1149-1158. https://doi.org/10.3906/kim-1812-29.
  15. Isildak, Ö., Özbek, O. (2020). Silver(I)-selective PVC membrane potentiometric sensor based on 5,10,15,20- tetra(4-pyridyl)-21H, 23H-porphine and potentiometric applications. Journal of Chemical Science, 132, 29. https://doi.org/10.1007/s12039-019-1734-2
  16. Isildak, Ö., Özbek, O. (2020). Application of Potentiometric Sensors in Real Samples. Critical Reviews in Analytical Chemistry, 1-14. https://doi.org/10.1080/10408347.2019.1711013
  17. Kadirvelu, K., Thamaraiselvi, K., Namasivayam, C. (2001). Removal of heavy metals from industrial wastewaters by adsorption onto activated carbon prepared from an agricultural solid waste. Bioresource Technology, 76(1), 63-65. https://doi.org/10.1016/S0960-8524(00)00072-9
  18. Kamal, A., Tejpal, R., Bhalla, V., Kumar, M., Mahajan, R. K. (2015). Selective and sensitive lead (II) solid- contact potentiometric sensor based on naphthalene-sulfonamide derivative. International Journal of Environmental Science and Technology, 12, 2567–2578. https://doi.org/ 10.1007/s13762-014-0621-0
  19. Kanberoglu, G. S., Coldur, F., Topcu, C., Cubuk, O. (2015). PVC-membrane potentiometric sensor for the determination of Tamoxifen in pharmaceutical formulations. IEEE Sensors Journal, 15(11), 6199- 6207. https://doi.org/10.1109/JSEN.2015.2454053
  20. Kopytin, A. V., German, K. E., Zhizhin, K. Y., Zhukov, A. F., Ilyin, E. G., Zhukova T. V. (2016). Ion selective potentiometric sensor based on single crystalline KTiOPO4 for determination of K+-ions. Procedia Engineering, 168, 440-443. https://doi.org/10.1016/j.proeng.2016.11.539
  21. Kumar, P. (2012). All Solid State Nickel(II)-Selective Potentiometric Sensor Based on an Upper Rim Substituted Calixarene. Electroanalysis, 24(10), 2005-2012. https://doi.org/10.1002/elan.201200228
  22. Kumar, P., Shim, Y-B. (2009). A novel cobalt(II)-selective potentiometric sensor based on p-(4-n- butylphenylazo)calix[4]arene. Talanta, 77, 1057-1062. https://doi.org/10.1016/j.talanta.2008.08.003
  23. Masrournia, M., Zamani H. A., Mohamadzadeh, H., Seyedi, S. M., Ganjali, M. R., Eshghi H. (2009). A Silver(I) PVC-Membrane Sensor Based on Synthesized Dilaktam Crown Ether. Journal of the Chilean Chemical Society, 53(5), 63-67. http://dx.doi.org/10.4067/S0717-97072009000100015
  24. Murali Krishna, I. V., Manickam, V. (2017). Environmental Management: Science and Engineering for Industry. (1st ed.) USA.
  25. Rezaei, B., Hadadzadeh, H., Azimi, A. (2011). Nickel(II) Selective PVC-BasedMembrane Sensor Using a Schiff Base. International Journal of Spectroscopy, 1-7. http://dx.doi.org/10.1155/2011/746372
  26. Singh, A. K., Mehtab, S., Singh, U. P., Aggarwal, V. (2007). Tripodal chelating ligand-based sensor for selective determination of Zn(II) in biological and environmental samples. Analytical and Bioanalytical Chemistry, 388,1867–1876. https://doi.org/10.1007/s00216-007-1434-5
  27. Topcu, C., Coldur, F., Andac, M., Isildak, I., Senyüz, N., Bati, H. (2011). Ag+- selective poly vinyl chloride membrane electrode based on [N,N-ethylenebis-(3-methoxy-salicylaldimine)]. Current Analytical Chemistry, 7(2), 136-145. https://doi.org/10.2174/157341111794814995
  28. Topcu, C. (2016). Nikel-Sakkarin Temelli PVC-Membran Karbonat (CO32-) Seçici Elektrot ve Potansiyometrik Uygulamaları. Karaelmas Fen ve Mühendislik Dergisi, 6(2), 283-292. http://dx.doi.org/10.7212%2Fzkufbd.v6i2.231
  29. Uner Bahar, D., Topcu, C., Ozcimen, D., Isildak, I. (2020). A Novel Borate Ion Selective Electrode Based On Carbon Nanotube-Silver Borate. International Journal of Electrochemical Science, 15, 899-914. https://doi.org/ 10.20964/2020.01.40
  30. Vlascici, D., Fagadar-Cosma, E., Pica, E. M., Cosma, V., Bizerea, O., Mihailescu, G., Olenic, L. (2008). Free Base Porphyrins as Ionophores for Heavy Metal Sensors. Sensors, 8, 4995-5004. https://doi.org/10.3390/s8084995
  31. Yolcu, M. ve Dere, N. (2009). A novel copper selective sensor based on ion imprinted 2-vinylpyridine polymer. Canadian Journal of Chemistry, 96, 1027-1036. https://doi.org/10.1139/cjc-2018-0178
  32. Zamani, A. Z. ve Sahebnasagh, S. (2013). Potentiometric detection of Cr3+ ions in solution by a chromium(III) electrochemical sensor based on diethyl 2-phthalimidomalonate doped in polymeric membrane. International Journal of Electrochemical Science, 8, 3708-3720.
  33. Zamani, A. Z., Ganjali, M. R., Pooyamanesh, M. J. (2006). Zinc(II) PVC-Based Membrane Sensor Based on 5,6-Benzo-4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo[8,8,8]hexacos-5-ene. Journal of the Brazilian Chemical Society, 17(1), 149-155.