EFFECTS OF SUPERHEATING AND SUBCOOLING IN A VAPOR COMPRESSION REFRIGERATION SYSTEM WITH R507A REFRIGERANT

Bayram Kılıç(BURDUR MEHMET AKİF ERSOY UNIVERSITY)0000-0002-8577-1845
Emre Arabacı(PAMUKKALE UNIVERSITY)0000-0002-6219-7246
Pages
—
Publication Date
2023-12-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the analysis made depending on the change in condenser temperature, superheat and subcooling temperatures, the highest COP value of the cycle was found to be 4.367.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Vapor compression cooling systems are the most used and most efficient cooling method in industrial and commercial applications.
📊
Key Findings & Data:In this article, the effects of superheating and subcooling on the system performance in the vapor compression refrigeration cycle (VCRS) using R507A were theoretically examined.
💡
Conclusion & Impact:In the analysis made depending on the change in condenser temperature, superheat and subcooling temperatures, the highest COP value of the cycle was found to be 4.367.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Refrigeration system · COP · Energy analysis

Abstract

Vapor compression cooling systems are the most used and most efficient cooling method in industrial and commercial applications. The reason of these systems are preferred is that they reduce environmental impacts, provide energy efficiency and have economic advantages. In this article, the effects of superheating and subcooling on the system performance in the vapor compression refrigeration cycle (VCRS) using R507A were theoretically examined. The thermodynamic data used the calculation were taken from the Coolpack program. The performance analysis of the VCRS were made for different operating conditions. In the analyses, the evaporator temperature was changed between -5 and -25 oC, the condenser temperature was changed between 25 and 45 oC, and the superheat and subcooling temperatures were changed as 0, 3, 5 and 7 oC. In the analysis made depending on the change in evaporator temperature, superheat and subcooling temperatures, the highest COP value of the cycle is 3.71. In the analysis made depending on the change in condenser temperature, superheat and subcooling temperatures, the highest COP value of the cycle was found to be 4.367.

🔖

Cite This Article

Kılıç, B., Arabacı, E. (2023). EFFECTS OF SUPERHEATING AND SUBCOOLING IN A VAPOR COMPRESSION REFRIGERATION SYSTEM WITH R507A REFRIGERANT. Scientific Journal of Mehmet Akif Ersoy University, Volume: 6 Issue: 2. https://ajindex.com/articles/1540563

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Şencan, A., Selbaş, R., Kızılkan, Ö., Kalogirou, S.A. (2006). Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles. Internatıonal Journal Of Energy Research vol.30, p.323-347.
  2. Memet, F. (2022). Effects of vaporization temperature and subcooling variation on the performance of a vapour compression refrigeration cycle working with R134a, met on newer ships. International Journal of Modern Manufacturing Technologies vol. 14, no. 3, p. 2067-3604.
  3. Kızılkan, Ö., Selbaş, R., Şencan, A. (2006). Buhar sıkıştırmalı soğutma sistemlerinde aşırı soğutma ve aşırı kızdırma etkisinin ısıl ekonomik açıdan incelenmesi. J. Fac. Eng. Arch. Gazi Univ. vol. 21, no. 2, p. 387-393.
  4. Yıldırım, R., Şencan Şahin, A. (2023). Prediction of energy and exergy performance for subcooled and superheated vapor compression refrigeration system working with new generation refrigerants. Sustainable Energy Technologies and Assessments vol. 57, 103177.
  5. Cingiz Z., Katırcıoğlu F., Çay Y., Kolip A. (2020). Buhar sıkıştırmalı soğutma sisteminde R22 alternatifi soğutucu akışkanların termodinamik analizi. Politeknik Dergisi vol. 23, no. 4, p. 1205-1212.
  6. Bakırcı, K., Çolak, D. (2012). Effect of a superheating and sub-cooling heat exchanger to the performance of a ground source heat pump system. Energy, vol. 44, p. 996-1004.
  7. https://refrigerants.com/wp-content/uploads/2019/12/SDS-R507A.pdf
  8. Çengel, A.Y. & Boles, A.M. (1994). Thermodynamics: An Engineering Approach. McGraw-Hill, New York, A.B.D.
  9. Kılıç, B. (2023). Energy analysis of vapor compression refrigeration system using R417B as refrigerant. Techno-Science vol. 6, no. 1, p. 27-31.
  10. Kılıç, B., Arabacı, E. (2018). Energy analysis of vapor compression refrigeration system using LPG (R1270-propylene) as refrigerant. MAKÜ-Uygulamalı Bilimler Dergisi vol. 2, no. 2, p. 75-81.
  11. Kılıç, B., İpek, O. (2021). Performance analysis of vapor compression refrigeration system using mixed refrigerant R410A. International Journal of Energy Applications and Technologies vol. 8, no. 2, p. 60-64.