Journals / Scientific Journal of Mehmet Akif Ersoy University / 2026 / Volume: 9 Issue: 1

A Low-Cost IoT Smart Pill Box with Physical Intake Verification: Design and Evaluation in Real-Life Use

Rabia Duman(MUĞLA SITKI KOÇMAN ÜNİVERSİTESİ)0009-0009-3351-9806
Ensar Arif Sağbaş(MUĞLA SITKI KOÇMAN ÜNİVERSİTESİ, TEKNOLOJİ FAKÜLTESİ, BİLİŞİM SİSTEMLERİ MÜHENDİSLİĞİ BÖLÜMÜ)0000-0002-7463-1150
Pages
—
Publication Date
2026-10-25
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The record was consistent, and the local alarm was a strong trigger for intake; consolidated caregiver notifications and peripheral power control are the next steps.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Medication non-adherence undermines the treatment of chronic diseases, and reminder applications cannot show whether a dose was taken.
📊
Key Findings & Data:This paper reports a 52-day field evaluation of a low-cost smart pill box that registers each intake event with an infrared sensor and a reed switch, time-stamps it with a battery-backed clock, queues events locally during network outages and forwards them to a Laravel server that alerts the patient, a caregiver and a physician by staged e-mails.
💡
Conclusion & Impact:The record was consistent, and the local alarm was a strong trigger for intake; consolidated caregiver notifications and peripheral power control are the next steps.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Smart pill box · Medication adherence · Internet of Things

Abstract

Medication non-adherence undermines the treatment of chronic diseases, and reminder applications cannot show whether a dose was taken. This paper reports a 52-day field evaluation of a low-cost smart pill box that registers each intake event with an infrared sensor and a reed switch, time-stamps it with a battery-backed clock, queues events locally during network outages and forwards them to a Laravel server that alerts the patient, a caregiver and a physician by staged e-mails. One user with multiple sclerosis, who is also an author, used the device with three scheduled doses per day. Of 155 planned doses, 90 were taken (58.1%); excluding an 8-day period in which the device was deliberately switched off, adherence was 68.7% (95% CI 59–78%) and differed between phases (83.3%, 47.6% and 73.2%). Taken doses were registered at a median deviation of 0 min, 94.4% within five minutes of the alarm; e-mail reminders were followed by intake in 4 of 69 cases. All 90 events recorded after installation matched a planned dose, all 103 device packets were consistent with the database, the median device-to-server delay was 2 s, and the notification chain fired at its thresholds in every case. Deep sleep extended the runtime on a 10,000 mAh power bank by 2.6-fold (from 14 h to 36 h). The sensors register intake events but do not verify ingestion. The record was consistent, and the local alarm was a strong trigger for intake; consolidated caregiver notifications and peripheral power control are the next steps.

🔖

Cite This Article

Duman, R., Sağbaş, E. A. (2026). A Low-Cost IoT Smart Pill Box with Physical Intake Verification: Design and Evaluation in Real-Life Use. Scientific Journal of Mehmet Akif Ersoy University, Volume: 9 Issue: 1. https://doi.org/10.70030/sjmakeu.2057008

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (26)

  1. Sabaté, E., Ed. (2003). Adherence to Long-Term Therapies: Evidence for Action. Geneva, Switzerland: World Health Organization. [Online]. Available: https://iris.who.int/server/api/core/bitstreams/121c6b73-8651-442f-9560-e3b1d9c8a75c/content
  2. Andrade, S. E., Kahler, K. H., Frech, F., & Chan, K. A. (2006). Methods for evaluation of medication adherence and persistence using automated databases. Pharmacoepidemiology and Drug Safety, 15(8), 565–574. https://doi.org/10.1002/pds.1230
  3. Kim, S. K., Park, S. Y., Hwang, H. R., Moon, S. H., & Park, J. W. (2025). Effectiveness of mobile health intervention in medication adherence: A systematic review and meta-analysis. Journal of Medical Systems, 49(1), Article 13. https://doi.org/10.1007/s10916-024-02135-2
  4. Dadkhah, M., Mehraeen, M., Rahimnia, F., & Kimiafar, K. (2021). Use of Internet of Things for chronic disease management: An overview. Journal of Medical Signals and Sensors, 11(2), 138–157. https://doi.org/10.4103/jmss.JMSS_13_20
  5. Shahani, A., Nieva, H. R., Czado, K., Shannon, E., Gaetani, R., Gresham, M., Garcia, J. C., Ganesan, H., Cerciello, E., Dave, J., Jain, R., & Schnipper, J. L. (2022). An electronic pillbox intervention designed to improve medication safety during care transitions: Challenges and lessons learned regarding implementation and evaluation. BMC Health Services Research, 22, Article 1304. https://doi.org/10.1186/s12913-022-08702-y
  6. Shanmugam, D. B., Dhilipan, J., Sivasankari, A., Munusamy, S., & Karpagam, S. (2020). Smart pill box using IoT and cloud. Bioscience, Biotechnology Research Communications, 13(4), 139–145.
  7. Sivaguru, R., & Revathi, P. (2025). Smart IoT-based medication adherence system for real-time patient monitoring and alerts. International Journal of Science and Research Archive, 14(3), 1479–1490. https://doi.org/10.30574/ijsra.2025.14.3.0823
  8. Bhat, R. B., Preethi, M., & Reshma. (2024). Pillbox: A smart solution for personalized medication scheduling and monitoring. International Journal of Research in Applied Science and Engineering Technology, 12(12), 1097–1102. https://doi.org/10.22214/ijraset.2024.65975
  9. Saris, N. N. H., Wei, B. B. W., Muhammad, N. A. M., Sukarnoor, N. I. M., Lim, Z., Daud, N. A., Halim, N. A., Nazim, M. H. M., & Muhammad, N. A. (2025). IoT and mobile app integration in a smart pill box for enhanced health management. In Proceedings of the 2025 IEEE International Conference on Automation, Control and Intelligent Systems (I2CACIS) (pp. 61–65). Kuala Lumpur, Malaysia. https://doi.org/10.1109/I2CACIS65476.2025.11100940
  10. Al-hussaniy, H. A., & Oraibi, A. I. (2026). Development of a smart pillbox system to improve medication adherence. Revista Colombiana de Ciencias Químico-Farmacéuticas, 55(2), 490–506. https://doi.org/10.15446/rcciquifa.v55n2.124746
  11. Jayavardhan, K., Manoj Kumar, M., Akhila, C., Zubair, K., & Bharathi, T. (2026). Design and development of smart IoT enabled pill dispenser real time alert system. International Journal of Science and Technology, 17(2), Article IJSAT260210711.
  12. Al-Mahmud, O., Khan, M. K., Roy, R., & Alamgir, F. M. (2020). Internet of Things (IoT) based smart health care medical box for elderly people. In Proceedings of the 2020 International Conference on Emerging Technologies (INCET) (pp. 1–6). https://doi.org/10.1109/INCET49848.2020.9153994
  13. Patil, C. H., Lightwala, N., Sherdiwala, M., Vibhute, A. D., Naik, S. A., & Mali, S. M. (2022). An IoT based smart medicine dispenser model for healthcare. In Proceedings of the 2022 IEEE World Conference on Applied Intelligence and Computing (AIC) (pp. 391–395). https://doi.org/10.1109/AIC55036.2022.9848934
  14. Díaz-Jiménez, D., López Ruiz, J. L., Gaitán-Guerrero, J. F., & Espinilla Estévez, M. (2025). Understanding patient adherence through sensor data: An integrated approach to chronic disease management. Applied Sciences, 15(24), Article 13226. https://doi.org/10.3390/app152413226
  15. Abril-Jiménez, P., Merino-Barbancho, B., Fico, G., Martín Guirado, J. C., Vera-Muñoz, C., Mallo, I., Lombroni, I., Cabrera Umpierrez, M. F., & Arredondo Waldmeyer, M. T. (2023). Evaluating IoT-based services to support patient empowerment in digital home hospitalization services. Sensors, 23(3), Article 1744. https://doi.org/10.3390/s23031744
  16. Arduino. (2026). Arduino Nano ESP32 (ABX00083) datasheet. [Online]. Available: https://docs.arduino.cc/resources/datasheets/ABX00083-datasheet.pdf
  17. Fielding, R. T. (2000). Architectural styles and the design of network-based software architectures [Ph.D. dissertation]. University of California, Irvine, CA, USA.
  18. Laravel LLC. (2026). Laravel 12.x documentation. [Online]. Available: https://laravel.com/docs/12.x
  19. Efron, B., & Tibshirani, R. J. (1993). An Introduction to the Bootstrap. New York, NY, USA: Chapman & Hall.
  20. Clopper, C. J., & Pearson, E. S. (1934). The use of confidence or fiducial limits illustrated in the case of the binomial. Biometrika, 26(4), 404–413. https://doi.org/10.1093/biomet/26.4.404
  21. Hanley, J. A., & Lippman-Hand, A. (1983). If nothing goes wrong, is everything all right? Interpreting zero numerators. JAMA, 249(13), 1743–1745. https://doi.org/10.1001/jama.1983.03330370053031
  22. Espressif Systems. (2024). ESP32 series datasheet: Power management and low-power modes. Espressif Systems Co., Ltd.
  23. Baumgartner, P. C., Haynes, R. B., Hersberger, K. E., & Arnet, I. (2018). A systematic review of medication adherence thresholds dependent of clinical outcomes. Frontiers in Pharmacology, 9, Article 1290. https://doi.org/10.3389/fphar.2018.01290
  24. Sendelbach, S., & Funk, M. (2013). Alarm fatigue: A patient safety concern. AACN Advanced Critical Care, 24(4), 378–386. https://doi.org/10.1097/NCI.0b013e3182a903f9
  25. Dimitrievski, A., Filiposka, S., Melero, F. J., Zdravevski, E., Lameski, P., Pires, I. M., Garcia, N. M., Lousado, J. P., & Trajkovik, V. (2021). Rural healthcare IoT architecture based on low-energy LoRa. International Journal of Environmental Research and Public Health, 18(14), Article 7660. https://doi.org/10.3390/ijerph18147660
  26. Pamuk, N., & Güdül, Y. E. (2026). Beyond the gateway: A secure P2MP LoRa-based architecture for rural health via iterative key derivation. Black Sea Journal of Engineering and Science, 9(3), 1069–1091. https://doi.org/10.34248/bsengineering.1894126