Journals / Clinical Dentistry and Research / 2017 / Cilt: 41 - Sayı: 1

ADIN İMPLANTLARININ KISA DÖNEM RADYO FREKANS ANALIZ ÖLÇÜMLERİ

SHORT-TERM RADIO FREQUENCY ANALYSIS MEASUREMENTS OF ADIN IMPLANTS

Pages
10–18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Statistically no difference was found between the baseline and 8th week measurements (p>0.05).Conclusion: Measuring Implant Stability Quotient values can help the clinician understand the condition of the implant without disrupting the healing implant-bone interface, allowing to decide the loading time.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background and Aim: The purpose of this study was to understand and monitor the transition from primary to secondary stability of implants having sand blast large grit acid etched surface, for the timing of the prosthodontic treatment via using the Radio Frequency Analysis.
📊
Key Findings & Data:Subjects and Methods: Forty-two dental implants were placed in 19 patients and Implant Stability Quotient measurements were performed at baseline, 1st, 2nd, 3rd, 4th, 6th and 8th weeks.
💡
Conclusion & Impact:Statistically no difference was found between the baseline and 8th week measurements (p>0.05).Conclusion: Measuring Implant Stability Quotient values can help the clinician understand the condition of the implant without disrupting the healing implant-bone interface, allowing to decide the loading time.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background and Aim: The purpose of this study was to understand and monitor the transition from primary to secondary stability of implants having sand blast large grit acid etched surface, for the timing of the prosthodontic treatment via using the Radio Frequency Analysis. Subjects and Methods: Forty-two dental implants were placed in 19 patients and Implant Stability Quotient measurements were performed at baseline, 1st, 2nd, 3rd, 4th, 6th and 8th weeks. The lengths and diameters of the implants were also correlated with Implant Stability Quotient values. Results: The present data showed no correlation between lengths, diameters and Radio Frequency Analysis at any of the measurement times. In each group, implant stability at the baseline and 8th weeks showed significant higher Radio Frequency Analysis (RFA) values than the 2nd, 3rd and 4th weeks (p<0.05). Statistically no difference was found between the baseline and 8th week measurements (p>0.05).Conclusion: Measuring Implant Stability Quotient values can help the clinician understand the condition of the implant without disrupting the healing implant-bone interface, allowing to decide the loading time.

Özet

Amaç: Bu çalışmanın amacı, kumlanmış-asitlenmiş yüzeye sahip implantların primer stabiliteden sekonder stabiliteye geçişini, Radyo Frekans Analiz yöntemi kullanarak anlamak ve gözlemlemektir. Bireyler ve Yöntem: Ondokuz hastada 42 implant yerleştirilmiş ve başlangıç, 1, 2, 3, 4, 6 ve 8. haftalarda İmplant Stabilite ölçümleri (Implant Stability Quotient-ISQ) yapılmıştır. Bulgular: Elde edilen bilgiler, implantların boyu ve çapı ile Radyo Frekans Analiz ölçümleri arasında hiçbir zaman diliminde ilişki göstermemektedir. Tüm gruplarda implant stabilitesi, başlangıç ve 8. haftada 2, 3 ve 4. haftalara göre anlamlı derecede yüksek İmplant Stabilite ölçüm değeri göstermiştir (p 0.05).Sonuçlar: İmplant Stabilite değerlerini ölçmek, iyileşen implantkemik bağlantısına zarar vermeden, implantın iyileşme durumu hakkında fikir vererek yükleme zamanının kararında hekime yardımcı olabilir.

🔖

Cite This Article

DEMİR, B., BALCI, N., KARA, H. B., ÇAKAN, U., TOYGAR, H. U. (2017). ADIN İMPLANTLARININ KISA DÖNEM RADYO FREKANS ANALIZ ÖLÇÜMLERİ. Clinical Dentistry and Research, Cilt: 41 - Sayı: 1, 10–18. https://ajindex.com/articles/144855

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Adell R, Lekholm U, Rockler B, Branemark P-I. A 15 year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10: 387-416. Davies JE. Understanding peri-implant endosseous healing. J Dent Educ 2003; 67: 932-949.
  2. Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res 2003; 14: 251-262.
  3. Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J. Early bone formation adjacent to rough and turned endosseous implant surfaces. Clin Oral Implants Res 2004; 15: 381-392.
  4. Truhlar RS, Morris HF, Ochi S. Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the periotest device on endosseous dental implants. Ann Periodontol; 5: 42-55.
  5. Oh JS, Kim SG. Clinical study of the relationship between implant stability measurements using periotest and osstell mentor and bone quality assessment. Oral Surg Oral Med Oral Pathol Oral Radiol; 113: e35-40. Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechannical aspects and clinical implications. Periodontol 2000 2008; 47: 51 Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross- sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997; 8: 226-233.
  6. Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 2004; 15: 520-528.
  7. Glauser R, Sennerby L, Meredith N, Rée A, Lundgren A, Gottlow J et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004; 15: 434. Ersanli S, Karabuda C, Beck F, Leblebicioglu B. Resonance frequency analysis of one-stage dental implant stability during the osseointegration period. J Periodontol 2005; 76: 1066-1071.
  8. Valderrama P, Oates TW, Jones AA, Simpson J, Schoolfield JD, Cochran DL. Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodontol; 78: 262-272.
  9. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996; 7: 261-267.
  10. Makary C, Rebaudi A, Sammartino