Journals / Journal of the Turkish Chemical Society Section B: Chemical Engineering / 2026 / Volume: 1 Issue: Sp. is. 1 Special Issue

Effect of GLYMO/TEOS/MTEOS Sol-Gel Film Thickness on the Responses of Glucose Biosensor

Nizamettin Demirkıran(İnönü University)
Ergun Ekinci(Inonu University)
Pages
—
Publication Date
2017-10-20
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:800x600 Normal 0 21 false false false TR X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri",sans-serif; mso-bidi-font-family:"Times New Roman";} In the present study, the effect of the film thickness on the responses of a glucose biosensor was investigated.
📊
Key Findings & Data:The sol-gel coating solutions were prepared by using (3-Glycidoxylpropyl) trimethoxysilane (GLYMO), tetraethoxysilane (TEOS), and methyltriethoxysilane (MTEOS).
💡
Conclusion & Impact:It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Biosensor · glucose · glucose oxidase

Abstract

800x600 Normal 0 21 false false false TR X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri",sans-serif; mso-bidi-font-family:"Times New Roman";} In the present study, the effect of the film thickness on the responses of a glucose biosensor was investigated. The modified platinum electrodes used in the study were constructed by immobilization of glucose oxidase under a film layer of the sol-gel coating solution. The sol-gel coating solutions were prepared by using (3-Glycidoxylpropyl) trimethoxysilane (GLYMO), tetraethoxysilane (TEOS), and methyltriethoxysilane (MTEOS). Electrochemical measurements were carried out amperometrically by determining hydrogen peroxide released by the enzymatic reaction between glucose and glucose oxidase. It was found that the amperometric responses of the sensor decreased with increasing the volume of coating solution dropped on the adsorbed enzyme. It was determined that the film thickness has a significantly influence on the sensor responses. It was observed that the amperometric responses decreased by 85% when the volume of the coating solution dropped on the electrode increased from 4 µL to 12 µL .

🔖

Cite This Article

Demirkıran, N., Ekinci, E. (2017). Effect of GLYMO/TEOS/MTEOS Sol-Gel Film Thickness on the Responses of Glucose Biosensor. Journal of the Turkish Chemical Society Section B: Chemical Engineering, Volume: 1 Issue: Sp. is. 1 Special Issue. https://ajindex.com/articles/1426215

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Li J, Chia L.S., Goh N.K., Tan S.N., Ge H. Mediated amperometric glucose sensor modified by the sol-gel method, Sens Actuators B,1997;40:135-141. DOI:10.1016/S0925-4005(97)80252-3
  2. Chaubey A, Malhotra B.D. Mediated biosensors, Biosens Bioelectron, 2002; 17:441-456. DOI:10.1016/S0956-5663(01)00313-X
  3. Freire R.S., Pessoa C.A., Mello L.D., Kubota L.T. Direct electron transfer:An approach for electrochemical biosensors with higher selectivity and sensitivity, J Braz Chem Soc, 2003; 14:230-243. http://jbcs.sbq.org.br/imageBank/PDF/v14n2a08.pdf
  4. Wang J. Electrochemical glucose biosensors, Chem Rev, 2008;108:814-825. DOI:10.1021/cr068123a
  5. Collinson M.M. Analytical applications of organically modified silicates, Mikrochim Acta, 1998; 129:149-165. DOI:10.1007/BF01244737
  6. Jin W, Brennan J.D., Properties and application of proteins encapsulated within sol-gel derived materials, Anal Chim Acta, 2002;461:1-36. DOI:10.1016/S0003-2670(02)00229-5
  7. Thenmozhi K, Narayanan S.S. Electrochemical sensor for H2O2 based on thionin immobilized 3-aminopropyltrimethoxy silane derived sol-gel thin film electrode, Sens Actuators B, 2007; 125:195-201. DOI:10.1016/j.snb.2007.02.006
  8. Tu Y.F., Di J.W., Chen X.J. Study of the nano-size silica sol-gel film as the matrix of chemically modified electrode, J Sol-Gel Sci Technol, 2005;33:187-191. DOI:10.1007/s10971-005-5613-6
  9. Pandey P.C., Upadhyay S, Pathak, H.C. A new glucose sensor based on encapsulated glucose oxidase within organically modified sol-gel glass, Sens Actuators B, 1999;60:83-89. DOI:10.1016/S0925-4005(99)00246-4
  10. Pauliukaite R, Brett C.M.A. Characterization of novel glucose oxysilane sol-gel electrochemical biosensors with copper hexacynoferrate mediator, Electrochim Acta, 2005;50:4973-4980. DOI:10.1016/j.electacta.2005.01.060
  11. Demirkıran N, Ekinci E. Immobilization of glucose oxidase in GLYMO/MTEOS sol-gel film for glucose biosensor application, Acta Chim Slov, 2012; 59:302-306. http://acta-arhiv.chem-soc.si/59/59-2-302.pdf