Journals / Journal of advances in vetbio science and techniques / 2026 / Issue: 3

Investigation of the relationship between heart rate measured automatically at different time intervals using the 3M littmann 3200 electronic stethoscope and heart rate measured by electrocardiography

Ömer Aydın(ATATÜRK ÜNİVERSİTESİ, VETERİNER FAKÜLTESİ)0000-0001-9444-1904
Pages
—
Publication Date
2026-10-19
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In conclusion, this study demonstrates that 30-second measurements obtained with the 3M Littmann 3200 ES provide heart rate measurements comparable to those obtained by ECG in healthy cats.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Cardiac auscultation is an indispensable method in the examination of cats.
📊
Key Findings & Data:With a traditional stethoscope, heart murmurs, gallop rhythms, and heart rate (HR) may not always be accurately assessed because of ambient noise interference.
💡
Conclusion & Impact:In conclusion, this study demonstrates that 30-second measurements obtained with the 3M Littmann 3200 ES provide heart rate measurements comparable to those obtained by ECG in healthy cats.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:3M Littmann 3200 electronic stethoscope · cat · electrocardiography

Abstract

Cardiac auscultation is an indispensable method in the examination of cats. With a traditional stethoscope, heart murmurs, gallop rhythms, and heart rate (HR) may not always be accurately assessed because of ambient noise interference. However, electronic stethoscopes (ESs) provide more uniform and amplified acoustic signals, allowing more accurate identification of physiological and pathological heart sounds during auscultation. The aim of this study was to determine the agreement, differences, and correlation between HR automatically measured using a 3M Littmann 3200 ES over 15-, 30-, and 60-second intervals and HR obtained by electrocardiography (ECG) in 34 healthy cats of various breeds, ages, and sexes. To this end, intraclass correlation coefficient (ICC), Bland–Altman, and Spearman’s correlation analyses were performed. ICC analysis showed moderate agreement between ECG and ES at the 15- and 60-second measurement intervals (r = 0.661, P < 0.001; r = 0.700, P < 0.001, respectively), whereas the 30-second interval demonstrated higher agreement (r = 0.812, P < 0.001). According to Bland-Altman analysis, 30-second HR measurements by ES showed the closest agreement with ECG (bias = 5.03; 95% limits of agreement = -34.34 to 44.40), compared to 15 seconds (bias = 9.41; -48.34 to 67.16) and 60 seconds (bias = 9.06; -41.88 to 59.99). In conclusion, this study demonstrates that 30-second measurements obtained with the 3M Littmann 3200 ES provide heart rate measurements comparable to those obtained by ECG in healthy cats.

🔖

Cite This Article

Aydın, Ö. (2026). Investigation of the relationship between heart rate measured automatically at different time intervals using the 3M littmann 3200 electronic stethoscope and heart rate measured by electrocardiography. Journal of advances in vetbio science and techniques, Issue: 3. https://doi.org/10.31797/vetbio.1931961

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (29)

  1. Abelson, D., & Kamens, E. A. (1977). Bedside measurement of systolic and diastolic time intervals using the stethometer. Cardiovascular Research, 11(3), 270-274. https://doi.org/10.1093/cvr/11.3.270
  2. Alibrandi, L., Vezzosi, T., Bozzolo, E., Grosso, G., Domenech, O., & Tognetti, R. (2024). Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats. Veterinary Research Communications, 49(1), 44. https://doi.org/10.1007/s11259-024-10600-z
  3. Bland, J. M., & Altman, D. G. (1999). Measuring agreement in method comparison studies. Statistical Methods in Medical Research, 8(2), 135-160. https://doi.org/10.1177/096228029900800204
  4. Blass, K. A., Schober, K. E., Bonagura, J. D., Scansen, B. A., Visser, L. C., Lu, J., Smith, D. N., & Ward, J. L. (2013). Clinical evaluation of the 3M Littmann Electronic Stethoscope Model 3200 in 150 cats. Journal of Feline Medicine and Surgery, 15(10), 893-900. https://doi.org/10.1177/1098612X13485480
  5. Bozzola, C., Ortolina, A., Guffanti, I., Alberti, E., Bronzo, V., & Zucca, E. (2024). Evaluation of a digital stethoscope for electrocardiographic recording in donkeys: preliminary results. Journal of Equine Veterinary Science, 135, 105048. https://doi.org/10.1016/j.jevs.2024.105048
  6. Chan, Y. H. (2003). Biostatistics 104: correlational analysis. Singapore Medical Journal, 44(12), 614-619.
  7. Chen, C. R., Chang, W. T., Chen, H. W., Wu, H. D., Hsieh, O. F., & Lin, C. H. (2024). Evaluating heart rate variability by a novel stethoscopic approach to minimise stress in cats. Journal of Feline Medicine and Surgery, 26(10), 1098612X241275296. https://doi.org/10.1177/1098612X241275296
  8. Chowdhury, M. E., Khandakar, A., Alzoubi, K., Mansoor, S., M. Tahir, A., Reaz, M. B. I., & Al-Emadi, N. (2019). Real-time smart-digital stethoscope system for heart diseases monitoring. Sensors, 19(12), 2781. https://doi.org/10.3390/s19122781
  9. de Oliveira Neto, N. R., Pinheiro, M. A., Carriço, A. S., Santos de Oliveira, M. M., Camara, M. F., & Lagreca, R. J. (2008). Abnormalities of the systolic time intervals obtained by electronic stethoscope in heart failure. The Internet Journal of Cardiology, 5(2), 1-7.
  10. Grenier, M. C., Gagnon, K., Genest, J., Durand, J., & Durand, L. G. (1998). Clinical comparison of acoustic and electronic stethoscopes and design of a new electronic stethoscope. American Journal of Cardiology, 81(5), 653-656. https://doi.org/10.1016/S0002-9149(97)00977-6
  11. Höglund, K., French, A., Dukes‐McEwan, J., Häggström, J., Smith, P., Corcoran, B., & Kvart, C. (2004). Low intensity heart murmurs in boxer dogs: inter‐observer variation and effects of stress testing. Journal of Small Animal Practice, 45(4), 178-185. https://doi.org/10.1111/j.1748-5827.2004.tb00221.x
  12. Ishmail, A. A., Wing, S., Ferguson, J., Hutchinson, T. A., Magder, S., & Flegel, K. M. (1987). Interobserver agreement by auscultation in the presence of a third heart sound in patients with congestive heart failure. Chest, 91(6), 870-873.
  13. Joshi, S. S., Patil, M. R., Kanawade N. P., & More, A. P. (2021). Bluetooth-based Wireless Digital Stethoscope, 2021 International Conference on Emerging Smart Computing and Informatics (ESCI), Pune, India, 197-202. https://doi.org/10.1109/ESCI50559.2021.9396835
  14. Kamran, H., Naggar, I., Oniyuke, F., Palomeque, M., Chokshi, P., Salciccioli, L., Stewart, M., & Lazar, J. M. (2013). Determination of heart rate variability with an electronic stethoscope. Clinical Autonomic Research, 23(1), 41-47.
  15. Kleiger, R. E., Stein, P. K., & Bigger Jr, J. T. (2005). Heart rate variability: measurement and clinical utility. Annals of Noninvasive Electrocardiology, 10(1), 88-101. https://doi.org/10.1111/j.1542-474X.2005.10101.x
  16. Lahiri, M. K., Kannankeril, P. J., & Goldberger, J. J. (2008). Assessment of autonomic function in cardiovascular disease: physiological basis and prognostic implications. Journal of the American College of Cardiology, 51(18), 1725-1733. https://doi.org/10.1016/j.jacc.2008.01.038
  17. Lok, C. E., Morgan, C. D., & Ranganathan, N. (1998). The accuracy and interobserver agreement in detecting the ‘gallop sounds’ by cardiac auscultation. Chest, 114(5), 1283-1288.
  18. Nunan, D., Sandercock, G. R., & Brodie, D. A. (2010). A quantitative systematic review of normal values for short‐term heart rate variability in healthy adults. Pacing and Clinical Electrophysiology, 33(11), 1407-1417. https://doi.org/10.1111/j.1540-8159.2010.02841.x
  19. Pedersen, H. D., Häggström, J., Falk, T., Mow, T., Olsen, L. H., Iversen, L., & Jensen, A. L. (1999). Auscultation in mild mitral regurgitation in dogs: observer variation, effects of physical maneuvers, and agreement with color Doppler echocardiography and phonocardiography. Journal of Veterinary Internal Medicine, 13(1), 56-64. https://doi.org/10.1111/j.1939-1676.1999.tb02166.x
  20. Portney, L. G., & Watkins, M. P. (2009). Foundations of clinical research: applications to practice. NJ: Pearson/Prentice Hall.
  21. Raftery, E. B., & Holland, W. W. (1967). Examination of the heart: an investigation into variation. American Journal of Epidemiology, 85(3), 438-444. https://doi.org/10.1093/oxfordjournals.aje.a120705
  22. Roos, M., Toggweiler, S., Zuber, M., Jamshidi, P., & Erne, P. (2006). Acoustic cardiographic parameters and their relationship to invasive hemodynamic measurements in patients with left ventricular systolic dysfunction. Congestive Heart Failure, 1, 19-24. https://doi.org/10.1111/j.1527-5299.2006.05769.x
  23. Sandercock, G. R., Bromley, P. D., & Brodie, D. A. (2005). The reliability of short-term measurements of heart rate variability. International Journal of Cardiology, 103(3), 238-247.
  24. Szilvási, V., Vörös, K., Manczur, F., Reiczigel, J., Novák, I., Máthé, Á., & Fekete, D. (2013). Comparison of traditional and sensor-based electronic stethoscopes in beagle dogs. Acta Veterinaria Hungarica, 61(1), 19-29. https://doi.org/10.1556/avet.2012.049
  25. Tavel, M. E. (2006). Cardiac auscultation: a glorious past—and it does have a future!. Circulation, 113(9), 1255-1259. https://doi.org/10.1161/CIRCULATIONAHA.105.591149
  26. Vezzosi, T., Alibrandi, L., Grosso, G., & Tognetti, R. (2023). Evaluation of a new smartphone-based digital stethoscope featuring phonocardiography and electrocardiography in dogs and cats. The Veterinary Journal, 295, 105987. https://doi.org/10.1016/j.tvjl.2023.105987
  27. Wagner, T., Fuentes, V. L., Payne, J. R., McDermott, N., & Brodbelt, D. (2010). Comparison of auscultatory and echocardiographic findings in healthy adult cats. Journal of Veterinary Cardiology, 12(3), 171-182. https://doi.org/10.1016/j.jvc.2010.05.003
  28. Ware, W. A., & Bonagura, J. D. (2021). Cardiovascular disease in companion animals: dog, cat and horse (2nd ed.). Boca Raton: CRC Press. https://doi.org/10.1201/9780429186639
  29. Yıldız, M., & Türkoğlu, Z. (2014, April). Feasibility of heart rate variability analysis with heart sounds. In 2014 22nd Signal Processing and Communications Applications Conference (SIU). 947-950. IEEE.