Journals / Mühendis ve Makina / 2026 / Cilt: 65 Sayı: 714

EXPERIMENTAL INVESTIGATION OF THE EFFECT OF PRODUCT TEMPERATURE CLASSES ON ENERGY CONSUMPTION IN A CLOSED DISPLAY REFRIGERATOR

TİCARİ BİR SOĞUTUCUDA ÜRÜN SICAKLIK SINIFLARININ ENERJİ TÜKETİMİNE ETKİSİNİN DENEYSEL OLARAK İNCELENMESİ

Mertkan Arslan(EGE ÜNİVERSİTESİ, FEN BİLİMLERİ ENSTİTÜSÜ, KİMYA MÜHENDİSLİĞİ ANABİLİM DALI)0000-0001-8359-7743
Hüseyin Günerhan(EGE ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ, MAKİNE MÜHENDİSLİĞİ BÖLÜMÜ)
Hakan Tavukçu(Uğur Soğutma Makinaları Sanayi ve Ticaret A.Ş)0009-0006-6318-2683
Binnur Soysal(Uğur Soğutma Makinaları Sanayi ve Ticaret A.Ş.)0009-0008-1165-0785
Sertan Aksoy(Uğur Soğutma Makinaları Sanayi ve Ticaret A.Ş)0009-0006-5524-9657
Bora Devrim(Uğur Soğutma Makinaları Sanayi ve Ticaret A.Ş)0009-0008-8749-1012
Pages
27–48
Publication Date
2024-04-29
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result, the energy consumption in the K1 temperature class was 5.37% and 2.83% higher in day and night modes, respectively, compared to the K4 temperature class.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the energy consumption of a vertical closed display refrigerator (680 Liters) in day-night modes and in different product temperature classes was experimentally investigated.
📊
Key Findings & Data:Closed display refrigerator works with R290 (propane) refrigerant.
💡
Conclusion & Impact:As a result, the energy consumption in the K1 temperature class was 5.37% and 2.83% higher in day and night modes, respectively, compared to the K4 temperature class.
🔬Design:Araştırma Makalesi
📍Scope:2022 Verileri
⚙️Variables:Ticari soğutucular · enerji verimliliği · enerji tüketimi

Abstract

In this study, the energy consumption of a vertical closed display refrigerator (680 Liters) in day-night modes and in different product temperature classes was experimentally investigated. Closed display refrigerator works with R290 (propane) refrigerant. Moreover, non-adiabatic capillary tube (suction line heat exchanger) system is used in the vapor compression refrigeration cycle. The experimental setup was carried out and calibrated in accordance with the TS EN ISO 22044:2022 standard. Experiments were carried out for 24 hours in a test room providing a temperature of 25°C ± 0.8°C and a relative humidity of 60% ± 2%. The commercial refrigerator has been tested under full load (700 pcs. 330 ml cans), in day and night modes, and in two different temperature classes (K1 and K4). Can temperatures which tested in the K1 temperature class were kept between 0°C-7°C. These temperature values for the K4 temperature is between 1°C-9°C. In the experiments of the K1 temperature class, 3.255 kWh/24h and 1.379 kWh/24h energy were consumed during the day and night, respectively. In the experiments of K4 temperature class, these values were measured as 3.089 kWh/24h in day mode and 1.341 kWh/24h in night mode. As a result, the energy consumption in the K1 temperature class was 5.37% and 2.83% higher in day and night modes, respectively, compared to the K4 temperature class.

Özet

Bu çalışmada, 680 litre hacim kapasiteli dikey, kapalı ve ısı cam kapılı bir ticari kutu soğutucusunun gece-gündüz modlarında ve farklı ürün sıcaklık sınıflarındaki enerji tüketimi deneysel olarak incelenmiştir. Ticari kutu soğutucusu R290 (propan) soğutma akışkanı ile çalışmakta ve buhar sıkıştırmalı soğutma çevrimi içerisinde adyabatik olmayan kılcal boru (emiş hattı ısı değiştiricisi) sistemi kullanılmaktadır. Deneysel düzenek, TS EN ISO 22044:2022 standartına uygun olarak kalibre edilmiş ve kurulmuştur. Deneyler, 25°C ± 0.8°C sıcaklık ve %60 ± %2 bağıl nem sağlayan bir iklimlendirme odasında 24 saat boyunca gerçekleştirilmiştir. Ticari soğutucu tam yük altında (700 adet 330 ml kutu), gece - gündüz modlarında ve iki farklı sıcaklık sınıfında (K1 ve K4) test edilmiştir. K1 ve K4 sıcaklık sınıfları, alüminyum içecek kutularının test sürecindeki sıcaklıklarını ifade eden bir test standartıdır. K1 sıcaklık sınıfında test edilen kutu sıcaklıkları; 0°C-7°C ve K4 sıcaklık sınıfında test edilen kutular ise; 1°C-9°C sıcaklıkları arasında kalması sağlanmıştır. K1 sıcaklık sınıfına ait deneylerde gündüz ve gece sırasıyla, 24 saatte 3.255 kWh ve 1.379 kWh enerji harcanmıştır. K4 sıcaklık sınıfına ait deneylerde ise bu değerler gündüz modunda 3.089 kWh ve gece gece modunda 1.341 kWh olarak ölçülmüştür. Sonuç olarak, K1 sıcaklık sınıfındaki enerji tüketimi K4 sıcaklık sınıfına göre gündüz ve gece modlarında sırasıyla %5.37 ve %2.83 daha yüksek ölçülmüştür.

🔖

Cite This Article

Arslan, M., Günerhan, H., Tavukçu, H., Soysal, B., Aksoy, S., Devrim, B. (2024). EXPERIMENTAL INVESTIGATION OF THE EFFECT OF PRODUCT TEMPERATURE CLASSES ON ENERGY CONSUMPTION IN A CLOSED DISPLAY REFRIGERATOR. Mühendis ve Makina, Cilt: 65 Sayı: 714, 27–48. https://doi.org/10.46399/muhendismakina.1460774

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (24)

  1. Chaomuang, N., Flick, D., Denis, A. ve Laguerre, O. (2019). Influence of operating conditions on the temperature performance of a closed refrigerated display cabinet. International Journal of Refrigeration, 103, 32-41. doi:10.1016/j.ijrefrig.2019.03.031
  2. Chaomuang, N., Flick, D. ve Laguerre, O. (2017). Experimental and numerical investigation of the performance of retail refrigerated display cabinets. Trends in Food Science & Technology, 70, 95-104. doi:10.1016/j.tifs.2017.10.007
  3. Çengel, Y., & Boles, M., Termodinamik: Mühendislik Yaklaşımı, 7. Baskı, Palme yayıncılık (2015)
  4. Elbel, S., Visek, M. ve Hrnjak, P. (2016). A Fair Comparison of CO2 and Propane Used in Light Commercial Applications Featuring Natural Refrigerants.
  5. Fricke, B. ve Becker, B. (2010). Energy Use of Doored and Open Vertical Refrigerated Display Cases.
  6. G ao, E., Cui, Q., Jing, H., Zhang, Z. ve Zhang, X. (2021). A review of application status and replacement progress of refrigerants in the Chinese cold chain industry. International Journal of Refrigeration, 128, 104-117. doi:10.1016/j.ijrefrig.2021.03.025
  7. Gao, Y., He, G., Cai, D. ve Fan, M. (2020). Performance evaluation of a modified R290 dual-evaporator refrigeration cycle using two-phase ejector as expansion device. Energy, 212, 118614. doi:10.1016/j.energy.2020.118614
  8. Jwo, C.-S., Ting, C.-C. ve Wang, W.-R. (2009). Efficiency analysis of home refrigerators by replacing hydrocarbon refrigerants. Measurement, 42(5), 697-701. doi:10.1016/j.measurement.2008.11.006
  9. Kulkarni, S., Chavali, S. ve Dikshit, S. (2023). A review on analysis of Vapour Compression Refrigeration System (VCRS) for its performance using different ecofriendly refrigerants and nanofluids. Materials Today: Proceedings, 72, 878-883. doi:10.1016/j.matpr.2022.09.085
  10. Mađerić, D., Pavković, B. ve Lenić, K. (2019). An experimental research on energy efficiency of a beverage cooler with the latent heat storage. Applied Thermal Engineering, 148, 270-277. doi:10.1016/j.applthermaleng.2018.11.026
  11. Ocak, C., Koşan, M., Erten, S., Nur Erdoğmuş, F. ve Öder, M. (2023). Comparison of different compressor technologies for refrigerated display cabinet: Experimental study. Materials Today: Proceedings, 81, 74-80. doi:10.1016/j.matpr.2023.01.213
  12. Rasti, M., Ban, J. H. ve Jeong, J. H. (2017). Development of a continuous empirical correlation for refrigerant mass flow rate through non-adiabatic capillary tubes. Applied Thermal Engineering, 127, 547-558. doi:10.1016/j.applthermaleng.2017.08.070
  13. Robertson G., (2015) Trial Retrofit of Doors on Open Refrigerated Display Cabinets Final Report. Roy, Z. ve Halder, G. (2020). Replacement of halogenated refrigerants towards sustainable cooling system: A review. Chemical Engineering Journal Advances, 3, 100027. doi:10.1016/j.ceja.2020.100027
  14. Sánchez, D., Andreu-Nácher, A., Calleja-Anta, D., Llopis, R. ve Cabello, R. (2022). Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a, R1234yf, R290, R1270, R600a and R744. Energy Conversion and Management, 256, 115388. doi:10.1016/j.enconman.2022.115388
  15. Sánchez, D., Cabello, R., Llopis, R., Arauzo, I., Catalán-Gil, J. ve Torrella, E. (2017). Energy performance evaluation of R1234yf, R1234ze(E), R600a, R290 and R152a as low-GWP R134a alternatives. International Journal of Refrigeration, 74, 269-282. doi:10.1016/j.ijrefrig.2016.09.020
  16. Sarker, D. ve Jeong, J. H. (2012). Development of empirical correlations for non-adiabatic capillary tube based on mechanistic model. International Journal of Refrigeration, 35(4), 974-983. doi:10.1016/j.ijrefrig.2012.01.021
  17. Selvnes, H., Allouche, Y., Manescu, R. I. ve Hafner, A. (2021). Review on cold thermal energy storage applied to refrigeration systems using phase change materials. Thermal Science and Engineering Progress, 22, 100807. doi:10.1016/j.tsep.2020.100807
  18. TS EN ISO 22044:2021,Ticari içecek soğutucuları Sınıflandırma, gereklilikler ve test koşulları.
  19. Van Beek, M. ve de Jong, H. (2014). Reducing Display Bottle Cooler Energy Consumption Using PCM As Active Thermal Storage.
  20. Wongwises, S. ve Chimres, N. (2005). Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator. Energy Conversion and Management, 46(1), 85-100. doi:10.1016/j.enconman.2004.02.011
  21. Xu, B. ve Bansal, P. K. (2002). Non-adiabatic capillary tube flow: A homogeneous model and process description. Applied Thermal Engineering, 22(16), 1801-1819. doi:10.1016/S1359-4311(02)00110-2
  22. Yadav, S., Liu, J. ve Kim, S. C. (2022). A comprehensive study on 21st-century refrigerants - R290 and R1234yf: A review. International Journal of Heat and Mass Transfer, 182, 121947. doi:10.1016/j.ijheatmasstransfer.2021.121947
  23. Zhao, H., Yuan, T., Gao, J., Wang, X. ve Yan, J. (2019). Conventional and advanced exergy analysis of parallel and series compression-ejection hybrid refrigeration system for a household refrigerator with R290. Energy, 166, 845-861. doi:10.1016/j.energy.2018.10.135
  24. Zheng, H., Tian, G., Zhao, Y., Jin, C., Ju, F. ve Wang, C. (2022). Experimental study of R290 replacement R134a in cold storage air conditioning system. Case Studies in Thermal Engineering, 36, 102203. doi:10.1016/j.csite.2022.102203