Journals / Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi / 2004 / Cilt: 19 Sayı: 4

A NEW TEST METHOD AND SYSTEM FOR THE MEASUREMENT OF Z-PARAMETER OF STANDARD PELTIER MODULES

Standart Termoelektrik Modülün Z Parametresinin Ölçülmesi İçin Yeni Yöntem Ve Yeni Sistem

Pages
467–473
Publication Date
2013-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Measured values have been found to be in close range with the manufacturer’s catalog data.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a new method for the measurement of figure of merit, Z, of a thermoelectric module has been introduced.
📊
Key Findings & Data:Then, the realized new test system has been used to measure the Z of a standard thermoelectric module (Melcor CP 1.4-127-10L).
💡
Conclusion & Impact:Measured values have been found to be in close range with the manufacturer’s catalog data.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:Termoelektrik modül · Figure of Merit · test sistemi

Abstract

In this study, a new method for the measurement of figure of merit, Z, of a thermoelectric module has been introduced. The new method depends on the measurement of thermoemf, voltage and hot side temperature of the module. A new microcontroller test system has been designed and realized using this new method. Then, the realized new test system has been used to measure the Z of a standard thermoelectric module (Melcor CP 1.4-127-10L). Measured values have been found to be in close range with the manufacturer’s catalog data.

Özet

Bu çalışmada, bir termoelektrik modülün soğutma performansını gösteren kalite faktörü (figure of merit - Z) parametresinin belirlenmesi için termoemk, gerilim ve sıcak yüzeyin sıcaklığının ölçümüne dayalı yeni bir yöntem kullanılmıştır. Bu yönteme göre çalışan yeni bir mikrodenetleyici test sistemi gerçekleştirilmiştir. Yeni test sistemiyle Melcor firmasının ürettiği standart (CP 1.4-127-10L) modülün Z değeri ölçülmüştür. Bu değerler Melcor tarafından verilen Z değerleri ile kıyaslanmıştır. Bu değerler birbirine oldukça yakın çıkmıştır.

🔖

Cite This Article

Ahıska, R., Ciylan, B., Savaş, Y., Güler, İ. (2013). A NEW TEST METHOD AND SYSTEM FOR THE MEASUREMENT OF Z-PARAMETER OF STANDARD PELTIER MODULES. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 19 Sayı: 4, 467–473. https://ajindex.com/articles/1079111

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (49)

  1. Heylen, A. E. D., “Figure of Merit determination
  2. of Thermo-electric Modules”, Energy
  3. Conversion, Cilt 15, pp 65-70, 1975.
  4. Bowley A E, Inst A., Cowles L E J., Williams G
  5. J., Goldsmid H J, Inst F, “Measurement of the
  6. figure of merit of a thermoelectric material”,
  7. Journal of Scientific Instruments, Cilt 38 pp
  8. 435, 1961.
  9. Harman T. C., “Special Techniques for
  10. measurement of thermoelectric properties”, J.
  11. Appl. Phys., Cilt 29, pp 1373-1379, 1958.
  12. Goldsmid H. J., “A simple technique for
  13. determining the Seebeck coefficient of
  14. thermoelectric materials”, Journal of Physics E:
  15. Scientific Instruments, Cilt 19, pp 921-922,
  16. Buist R. J., “Methodology for testing
  17. thermoelectric materials and devices” CRC
  18. Handbook of Thermoelectrics Editör: Rowe, D.
  19. M., CRC Pres. Inc.,Florida, ABD., 189-209,
  20. Summasekera G. U.,Grigorian L., Eklund P. C.,
  21. “Low-Temperature thermoelectrical power
  22. measurement using analogue subtraction”,
  23. Measurement of Science and Technology, Cilt, pp 273-277, 2000.
  24. Waclawek W., and Zabkowska M., “Apparatus
  25. for the measurement of thermoelectrical
  26. properties”, Journal of Physics E: Scientific
  27. Instruments, Cilt 14, pp 618-620, 1981.
  28. Huang B. J., Chin C. J., Duang C. L., “A design
  29. method of thermoelectric cooler” International
  30. Journal of Refrigeration, Cilt 23, pp 208-218,
  31. Min G., Rowe, D. M., “Improved model for
  32. calculating the coefficient of performance of a
  33. Peltier module”, Energy conversion and
  34. management, Cilt 41, pp 163-171, 2000.
  35. Min G., Rowe D. M., “A novel principle
  36. allowing rapid and accurate measurement of a
  37. dimensionless thermoelectric figure of merit”,, pp 1261-1262, 2001.
  38. http://www.melcor.com homepage of Melcor,
  39. Xuan X. C., Ng K. C., Yap C., Chua H. T., “A
  40. general model for studying effects of interface
  41. layers on thermoelectric devices performance”,
  42. International Journal of Heat and Mass
  43. Transfer, Cilt 45, pp 5159–5170, 2002.
  44. Xuan X. C., “Investigation of thermal contact
  45. effect on thermoelectric coolers”, Energy
  46. conversion and management, Cilt 44, pp 399-, 2003.
  47. Ioffe A. F., Polucenie holoda
  48. Poluprovodnikovıe Termoelementı ed P V
  49. Gulteif Moskov Pres., Moskov, Rusia, 1960.