FUZZY CONTROL OF CIRCUIT BREAKERS IN POWER TRANSFORMER CENTERS

Sayfa
93–98
Yayın Tarihi
2019-12-16
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Human errors have been minimized by the control of breakers in the substation with fuzzy logic.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Transformer outages resulting from malfunctions by automatic maneuvers should be reflected to the system as soon as possible.
📊
Temel Bulgular & Veri:Disruptions resulting from interruptions and losses should be minimized.
💡
Sonuç & Katkı:Human errors have been minimized by the control of breakers in the substation with fuzzy logic.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Power Transformers · Transformer Breakers · Fuzzy Logic

Abstract

Transformer outages resulting from malfunctions by automatic maneuvers should be reflected to the system as soon as possible. Disruptions resulting from interruptions and losses should be minimized. In this study, Fuzzy Logic Control of Cutters in Transformer Centers has been provided. Since the energy parameters of the controlled electricity distribution line has been able to monitored continuously, energy consumption has been controlled. The fault conditions of all the elements in the substation are immediately determined and immediate intervention is possible. Human errors have been minimized by the control of breakers in the substation with fuzzy logic.

🔖

Bu Makaleye Atıf Yap

ZİLE, M. (2019). FUZZY CONTROL OF CIRCUIT BREAKERS IN POWER TRANSFORMER CENTERS. International Journal of Engineering and Innovative Research, Cilt: 1 - Sayı: 2, 93–98. https://ajindex.com/articles/766881

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (4)

  1. Martin H. B. Joost S., Richard A., Jhon, E., (1996), Condition monitoring of high voltage circuit breakers, Afrıcon, IEEE Afrıcon 4th, vol. 2, pp. 880-885
  2. ANSI / IEEE, A Guide to Describe the Occurrence and Mitigation of Switching Transients Induced by Transformer and Switching Device Interaction. C57.142
  3. Runde, M., Ottesen, G. E., Skyberg, B., Ohlen, M., (1996), Vibration analysis for diagnostic testing of circuit-breakers, IEEE Trans. Power Delivery, vol. 11, no. 4, pp. 1816-1823
  4. IEEE Guide for the Selection of Monitoring for Circuit Breakers, IEEE standard C37.10.1-2000.