FUZZY CONTROL OF CIRCUIT BREAKERS IN POWER TRANSFORMER CENTERS

Pages
93–98
Publication Date
2019-12-16
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Human errors have been minimized by the control of breakers in the substation with fuzzy logic.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Transformer outages resulting from malfunctions by automatic maneuvers should be reflected to the system as soon as possible.
📊
Key Findings & Data:Disruptions resulting from interruptions and losses should be minimized.
💡
Conclusion & Impact:Human errors have been minimized by the control of breakers in the substation with fuzzy logic.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Power Transformers · Transformer Breakers · Fuzzy Logic

Abstract

Transformer outages resulting from malfunctions by automatic maneuvers should be reflected to the system as soon as possible. Disruptions resulting from interruptions and losses should be minimized. In this study, Fuzzy Logic Control of Cutters in Transformer Centers has been provided. Since the energy parameters of the controlled electricity distribution line has been able to monitored continuously, energy consumption has been controlled. The fault conditions of all the elements in the substation are immediately determined and immediate intervention is possible. Human errors have been minimized by the control of breakers in the substation with fuzzy logic.

🔖

Cite This Article

ZİLE, M. (2019). FUZZY CONTROL OF CIRCUIT BREAKERS IN POWER TRANSFORMER CENTERS. International Journal of Engineering and Innovative Research, Cilt: 1 - Sayı: 2, 93–98. https://ajindex.com/articles/766881

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. Martin H. B. Joost S., Richard A., Jhon, E., (1996), Condition monitoring of high voltage circuit breakers, Afrıcon, IEEE Afrıcon 4th, vol. 2, pp. 880-885
  2. ANSI / IEEE, A Guide to Describe the Occurrence and Mitigation of Switching Transients Induced by Transformer and Switching Device Interaction. C57.142
  3. Runde, M., Ottesen, G. E., Skyberg, B., Ohlen, M., (1996), Vibration analysis for diagnostic testing of circuit-breakers, IEEE Trans. Power Delivery, vol. 11, no. 4, pp. 1816-1823
  4. IEEE Guide for the Selection of Monitoring for Circuit Breakers, IEEE standard C37.10.1-2000.