FOTOPLETİSMOGRAFİ TEKNOLOJİSİNE DAYALI KALP ATIM HIZI ÖLÇÜMÜ YAPAN GİYİLEBİLİR AKILLI SAATLERİN KARŞILAŞTIRMALI DEĞERLENDİRİLMESİ: HUAWEI HONOR BAND 5 VS XIAOMI MI SMART BAND 5

COMPARATIVE EVALUATION OF WEARABLE SMARTWATCHES THAT MEASURE HEART RATE BASED ON PHOTOPLETHYSMOGRAPHY TECHNOLOGY: HUAWEI HONOR BAND 5 VS XIAOMI MI SMART BAND 5

Sayfa
105–118
Yayın Tarihi
2022-03-30
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Araştırma sonuçlarına göre, katılımcıların DKAH ölçümlerinde bu üç saat arasında istatistiksel olarak anlamlı bir farklılık olmadığı (Polar: 81,3 atım/dk, Huawei: 81,9 atım/dk, Xiaomi: 81,1 atım/dk) (p>0.05), fakat katılımcıların maksimum KAH’larının %75 (Polar: 142,9 atım/dk, Huawei: 121,1 atım/dk, Xiaomi: 121,2 atım/dk) (p<0.05) ve %100’üne (Polar: 190,5 atım/dk, Huawei: 162 atım/dk, Xiaomi: 157,5 atım/dk) (p<0.05) denk gelen ölçümlerinde ise istatistiksel olarak anlamlı farklılıklar olduğu gözlemlenmiştir.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Öz: Bu araştırmanın amacı, kalp atım hızı (KAH) ölçümünde fotopletismografi (PPG) teknolojisini kullanan Huawei Honor Band 5 (Huawei) ve Xiaomi Mi Smart Band 5 (Xiaomi) giyilebilir akıllı saatlerinin (GAS) KAH ölçümünde altın standart olarak referans alınan Polar V800 (Polar) saati karşısında geçerli veriler verip veremeyeceğinin kontrol edilmesidir.
📊
Temel Bulgular & Veri:Araştırmaya, Erzincan Binali Yıldırım Üniversitesi (EBYÜ), Spor Bilimleri Fakültesi öğrencisi, 11’i kadın, 19’u erkek toplam 30 katılımcı (Yaş: 21,9±3 yıl, Boy: 172±9,5 cm, Kilo: 70,6±12,4 kg) gönüllülük esasına göre katılmıştır.
💡
Sonuç & Katkı:Araştırma sonuçlarına göre, katılımcıların DKAH ölçümlerinde bu üç saat arasında istatistiksel olarak anlamlı bir farklılık olmadığı (Polar: 81,3 atım/dk, Huawei: 81,9 atım/dk, Xiaomi: 81,1 atım/dk) (p>0.05), fakat katılımcıların maksimum KAH’larının %75 (Polar: 142,9 atım/dk, Huawei: 121,1 atım/dk, Xiaomi: 121,2 atım/dk) (p<0.05) ve %100’üne (Polar: 190,5 atım/dk, Huawei: 162 atım/dk, Xiaomi: 157,5 atım/dk) (p<0.05) denk gelen ölçümlerinde ise istatistiksel olarak anlamlı farklılıklar olduğu gözlemlenmiştir.
🔬Tür:Uygulamalı Anket & Alan Araştırması
📍Kapsam:30 katılımcı
⚙️Değişkenler:Fotopletismografi · Giyilebilir Teknolojiler · Kalp Atım Hızı

Özet

Öz: Bu araştırmanın amacı, kalp atım hızı (KAH) ölçümünde fotopletismografi (PPG) teknolojisini kullanan Huawei Honor Band 5 (Huawei) ve Xiaomi Mi Smart Band 5 (Xiaomi) giyilebilir akıllı saatlerinin (GAS) KAH ölçümünde altın standart olarak referans alınan Polar V800 (Polar) saati karşısında geçerli veriler verip veremeyeceğinin kontrol edilmesidir. Araştırmaya, Erzincan Binali Yıldırım Üniversitesi (EBYÜ), Spor Bilimleri Fakültesi öğrencisi, 11’i kadın, 19’u erkek toplam 30 katılımcı (Yaş: 21,9±3 yıl, Boy: 172±9,5 cm, Kilo: 70,6±12,4 kg) gönüllülük esasına göre katılmıştır. Katılımcılara Polar, Huawei ve Xiaomi saatleri aynı anda ve farklı kollara takılmıştır. Polar saat takılı olduğu sağ kolda sabit kalırken, Huawei sağ ve Xiaomi ise sol kola takılmıştır. Katılımcıların Dinlenik Kalp Atım Hızları (DKAH) kaydedildikten sonra katılımcılar şiddeti sürekli artan Yo-Yo dinlenmeli koşu testine tabi tutularak ulaşabildikleri maksimum KAH’larının %75 ve %100’üne ulaşan değerleri ölçülmüştür. Her mekik sonunda katılımcıların üzerinde yer alan üç farklı saatten KAH ölçümleri alınarak kaydedilmiştir. Verilerin değerlendirilmesinde One-Sample T Testi, Pearson Korelasyon Katsayısı, Sınıfiçi Korelasyon Katsayısı (ICC) ve Bland-Altman Analizi kullanılmıştır. Araştırma sonuçlarına göre, katılımcıların DKAH ölçümlerinde bu üç saat arasında istatistiksel olarak anlamlı bir farklılık olmadığı (Polar: 81,3 atım/dk, Huawei: 81,9 atım/dk, Xiaomi: 81,1 atım/dk) (p>0.05), fakat katılımcıların maksimum KAH’larının %75 (Polar: 142,9 atım/dk, Huawei: 121,1 atım/dk, Xiaomi: 121,2 atım/dk) (p<0.05) ve %100’üne (Polar: 190,5 atım/dk, Huawei: 162 atım/dk, Xiaomi: 157,5 atım/dk) (p<0.05) denk gelen ölçümlerinde ise istatistiksel olarak anlamlı farklılıklar olduğu gözlemlenmiştir. Bu sonuçlara göre, KAH takibinde Huawei ve Xiaomi saatlerinin günlük kullanımlarının uygun olabileceği, ancak egzersiz sırasında sporcu gelişimi ve sağlığı açısından kullanımlarının uygun olmayacağı anlaşılmaktadır.

Abstract

Wearable technologies are becoming indicators of variables such as the intensity and duration that the athletes want to achieve in their exercise and training. These indicators should be accurately reflected to the athletes in monitoring the exercise load. The purpose of this study was to investigate whether Huawei Honor Band 5 (Huawei) and Xiaomi Mi Smart Band 5 (Xiaomi) could provide valid scores when compared the Polar V800 (Polar), that has been accepted as gold standard for heart rate assessment. This research has a quasi-experimental research model without a control group. In total, 11 females and 19 males (Age: 21,9±3 years, height: 172±9,5 cm, weight: 70,6±12,4 kg) individuals from Erzincan Binali Yıldırım University (EBYU) voluntarily participated in this study Participants wore Polar, Huawei and Xiaomi watches at the same time and on different wrists. The Polar watch is fixed on the right wrist, while Huawei is on the right and Xiaomi is on the left. After recording resting heart rate, participants were asked to perform Yo-Yo intermittent recovery test protocol. During the test 75% and 100% of maximal heart rate scores were recorded. Each shuttle result was measured. One sample t-test, Pearson Correlation Coefficient, Intra Class Correlation Coefficient and Bland-Altman were used for statistical analysis. Results showed that there were no significant differences among each other at resting conditions (Polar: 81,3 bpm, Huawei: 81,9 bpm, Xiaomi: 81,1 bpm) (p>0.05). However significant findings were observed in both 75% (Polar: 142,9 bpm, Huawei: 121,1 bpm, Xiaomi: 121,2 bpm (p<0.05) and 100% (Polar: 190,5 bpm, Huawei: 162 bpm, Xiaomi: 157,5 bpm) (p<0.05) of their maximal heart rate. According to findings, Huawei and Xiaomi can be used for daily use, on the other hand it may not be appropriate for athletic performance assessments.

🔖

Bu Makaleye Atıf Yap

KAYABAŞ, O., CUĞ, M., BUDAK, C. (2022). FOTOPLETİSMOGRAFİ TEKNOLOJİSİNE DAYALI KALP ATIM HIZI ÖLÇÜMÜ YAPAN GİYİLEBİLİR AKILLI SAATLERİN KARŞILAŞTIRMALI DEĞERLENDİRİLMESİ: HUAWEI HONOR BAND 5 VS XIAOMI MI SMART BAND 5. SPORMETRE Beden Eğitimi ve Spor Bilimleri Dergisi, Cilt: 20 - Sayı: 1, 105–118. https://ajindex.com/articles/700610

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (5)

  1. Achten, J., Jeukendrup, A.E. (2003). Heart rate monitoring. Sports medicine, 33(7), 517±538. https://doi.org/10.2165/00007256-200333070-00004 PMID: 12762827 Allen, J. (2007). Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 28, https://doi.org/10.1088/0967-3334/28/3/r01 PMID: 17322588 Benedetto, S., Caldato, C., Bazzan, E., Greenwood, D., Pensabene, V., Actis, P. (2018). Assessment of the fitbit charge 2 for monitoring heart rate. PLOS ONE, 13(2), e0192691. https://doi.org/10.1371/journal.pone.0192691
  2. Butler, M.J., Crowe, J.A., Hayes-Gill, B.R., Rodmell, P.I. (2016). Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin. Physiological Measurement, 37, 27-37.
  3. Caminal, P., Sola, F., Gomis, P., Guasch, E., Perera, A., Soriano, N., Mont, L. (2018). Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions. Eur J Appl Physiol, 118(3), 669-677. doi:10.1007/s00421-018-3808-0. PMID: 29356949. Ghamari, M., Arora, H., Sherratt, R.S., Harwin, W. (2015). Comparison of low-power wireless communication technologies for wearable health-monitoring applications. I4CT - 2nd International Conference on Computer, Communications, and Control Technology in book, (ss. 1–6). Kuching: Malaysia. Giles, D., Draper, N., Neil, W. (2016) Validity of the Polar V800 heart rate monitor to measure RR intervals at rest. Eur J Appl Physiol, 116(3), 563-71. doi:10.1007/s00421-015-3303-9. PMID:26708360; PMCID:PMC4751190. Grand View Research. (2015). https://www.grandviewresearch.com/industry-analysis/wearable-technology-market adresinden erişilmiştir. Huang, C.J., Chan, H.L., Chang, Y.J., Chen, S.M., Hsu, M.J. (2021). Validity of the Polar V800 monitor for assessing heart rate variability in elderly adults under mental stress and dual task conditions. Int J Environ Res Public Health, 18(3), 869. doi:10.3390/ijerph18030869. PMID:33498381; PMCID:PMC7908342. Islam, S.M.R., Kwak, D., Kabir, H., et al. (2015). The internet of things for health care: A Comprehensive Survey. IEEE Access, 3, 678–708.
  4. Jo, E., Lewis, K., Directo, D., Kim, M.J., Dolezal, B.A. (2016). Validation of biofeedback wearables for photoplethysmographic. Heart rate tracking. Journal of Sports Science & Medicine, 15(3), 540±547 28179 John, D.E., Bronzino, J.D. (2012). Introduction to biomedical engineering. San Diego: Academic Press.
  5. Kavsaoğlu, A.R., Polat, K., Harihara