Dergiler / Turkish Journal of Chemistry / 2000 / Cilt: 24 - Sayı: 4

High-Performance Liquid Chromatographic Determination of Oxytetracycline Residue in Cured Meat Products

Sayfa
395–400
Yayın Tarihi
2022-11-05
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The development of a sensitive automated method for residue control of oxytetracycline (OTC) in cured meat (soudjouk) is described.
📊
Temel Bulgular & Veri:In HPLC, Hypersil BDC C18 column was used and OTC was separated at 24 oC using a mobile phase of H2O (pH=2.10 with H2SO4): ACN (85:15, v/v) at a flow rate of 1.5 ml/min.
💡
Sonuç & Katkı:The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Oxytetracycline · HPLC · soudjouk

Özet

The development of a sensitive automated method for residue control of oxytetracycline (OTC) in cured meat (soudjouk) is described. The principle steps involve the extraction of OTC from cured meat in the presence of citric acid with nitric acid, methanol and de-ionized water, and then the determination by HPLC. In HPLC, Hypersil BDC C18 column was used and OTC was separated at 24 oC using a mobile phase of H2O (pH=2.10 with H2SO4): ACN (85:15, v/v) at a flow rate of 1.5 ml/min. A variable wavelength detector was set at 360 nm. The detection limit of the method was calculated at 8 ng/g and the minimum detectable quantity was found as to be 40 mg/ml. The statistical evaluation demonstrated high absolute recoveries of from 78 to 100% for OTC. The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.

Abstract

The development of a sensitive automated method for residue control of oxytetracycline (OTC) in cured meat (soudjouk) is described. The principle steps involve the extraction of OTC from cured meat in the presence of citric acid with nitric acid, methanol and de-ionized water, and then the determination by HPLC. In HPLC, Hypersil BDC C18 column was used and OTC was separated at 24 oC using a mobile phase of H2O (pH=2.10 with H2SO4): ACN (85:15, v/v) at a flow rate of 1.5 ml/min. A variable wavelength detector was set at 360 nm. The detection limit of the method was calculated at 8 ng/g and the minimum detectable quantity was found as to be 40 mg/ml. The statistical evaluation demonstrated high absolute recoveries of from 78 to 100% for OTC. The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.

🔖

Bu Makaleye Atıf Yap

ŞENYUVA, H., SARICA, D. Y., ÖZDEN, T. (2022). High-Performance Liquid Chromatographic Determination of Oxytetracycline Residue in Cured Meat Products. Turkish Journal of Chemistry, Cilt: 24 - Sayı: 4, 395–400. https://ajindex.com/articles/602441

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...