Journals / Turkish Journal of Chemistry / 2000 / Cilt: 24 - Sayı: 4

High-Performance Liquid Chromatographic Determination of Oxytetracycline Residue in Cured Meat Products

Pages
395–400
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The development of a sensitive automated method for residue control of oxytetracycline (OTC) in cured meat (soudjouk) is described.
📊
Key Findings & Data:In HPLC, Hypersil BDC C18 column was used and OTC was separated at 24 oC using a mobile phase of H2O (pH=2.10 with H2SO4): ACN (85:15, v/v) at a flow rate of 1.5 ml/min.
💡
Conclusion & Impact:The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Oxytetracycline · HPLC · soudjouk

Abstract

The development of a sensitive automated method for residue control of oxytetracycline (OTC) in cured meat (soudjouk) is described. The principle steps involve the extraction of OTC from cured meat in the presence of citric acid with nitric acid, methanol and de-ionized water, and then the determination by HPLC. In HPLC, Hypersil BDC C18 column was used and OTC was separated at 24 oC using a mobile phase of H2O (pH=2.10 with H2SO4): ACN (85:15, v/v) at a flow rate of 1.5 ml/min. A variable wavelength detector was set at 360 nm. The detection limit of the method was calculated at 8 ng/g and the minimum detectable quantity was found as to be 40 mg/ml. The statistical evaluation demonstrated high absolute recoveries of from 78 to 100% for OTC. The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.

Özet

The development of a sensitive automated method for residue control of oxytetracycline (OTC) in cured meat (soudjouk) is described. The principle steps involve the extraction of OTC from cured meat in the presence of citric acid with nitric acid, methanol and de-ionized water, and then the determination by HPLC. In HPLC, Hypersil BDC C18 column was used and OTC was separated at 24 oC using a mobile phase of H2O (pH=2.10 with H2SO4): ACN (85:15, v/v) at a flow rate of 1.5 ml/min. A variable wavelength detector was set at 360 nm. The detection limit of the method was calculated at 8 ng/g and the minimum detectable quantity was found as to be 40 mg/ml. The statistical evaluation demonstrated high absolute recoveries of from 78 to 100% for OTC. The method was also used with 10 different cured meat samples marketed in Turkey, and in 7 of them the OTC residue was found to be higher than the tolerance levels accepted by the EU, FDA and Turkish Ministry of Agriculture.

🔖

Cite This Article

ŞENYUVA, H., SARICA, D. Y., ÖZDEN, T. (2022). High-Performance Liquid Chromatographic Determination of Oxytetracycline Residue in Cured Meat Products. Turkish Journal of Chemistry, Cilt: 24 - Sayı: 4, 395–400. https://ajindex.com/articles/602441

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...