Dergiler / Turkish Journal of Chemistry / 2001 / Cilt: 25 - Sayı: 2

Incorporation of EDTA for the Elimination of Metal Inhibitory Effects in an Amperometric Biosensor Based on Mushroom Tissue Polyphenol Oxidase

Sayfa
231–239
Yayın Tarihi
2022-11-04
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Mixed enzyme/carbon paste electrodes are receiving considerable attention for the preparation of fast responding biosensors.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Enzyme based biosensors are highly selective devices which rely on the specific binding of the target analyte (the substrate) to the active-site regions of the enzyme.
📊
Temel Bulgular & Veri:The enzymatic reaction between mushroom tissue polyphenol oxidase and its substrate phenol is coupled with the use of potassium ferrocyanide (K4Fe(CN)6) as the mediator in ammonia buffer solution (pH 8.80).
💡
Sonuç & Katkı:Mixed enzyme/carbon paste electrodes are receiving considerable attention for the preparation of fast responding biosensors.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Turk. J. Chem. · (2001) · 231-239. Full text: pdf Other articles published in the same issue: Turk. J. Chem.

Özet

Enzyme based biosensors are highly selective devices which rely on the specific binding of the target analyte (the substrate) to the active-site regions of the enzyme. The enzymatic reaction between mushroom tissue polyphenol oxidase and its substrate phenol is coupled with the use of potassium ferrocyanide (K4Fe(CN)6) as the mediator in ammonia buffer solution (pH 8.80). The response of devices is often affected by the presence of inhibitors, which combine with the free enzyme in a manner that prevents substrate binding. The objective of this study is to describe an efficient and yet simple strategy to eliminate the interference of metals in amperometric biosensing. The methods relies on in situ removal of the interfering metal by a surface-bound complexing agent, disodium ethylenediaminetetraacetate (EDTA). EDTA is incorporated into the electrode by mixing it within the enzyme-containing carbon paste matrix. Mixed enzyme/carbon paste electrodes are receiving considerable attention for the preparation of fast responding biosensors.

Abstract

Enzyme based biosensors are highly selective devices which rely on the specific binding of the target analyte (the substrate) to the active-site regions of the enzyme. The enzymatic reaction between mushroom tissue polyphenol oxidase and its substrate phenol is coupled with the use of potassium ferrocyanide (K4Fe(CN)6) as the mediator in ammonia buffer solution (pH 8.80). The response of devices is often affected by the presence of inhibitors, which combine with the free enzyme in a manner that prevents substrate binding. The objective of this study is to describe an efficient and yet simple strategy to eliminate the interference of metals in amperometric biosensing. The methods relies on in situ removal of the interfering metal by a surface-bound complexing agent, disodium ethylenediaminetetraacetate (EDTA). EDTA is incorporated into the electrode by mixing it within the enzyme-containing carbon paste matrix. Mixed enzyme/carbon paste electrodes are receiving considerable attention for the preparation of fast responding biosensors.

🔖

Bu Makaleye Atıf Yap

ERDEM, A., KERMAN, K., ÖZKAN, D., MERİÇ, B., ÖZSÖZ, M. (2022). Incorporation of EDTA for the Elimination of Metal Inhibitory Effects in an Amperometric Biosensor Based on Mushroom Tissue Polyphenol Oxidase. Turkish Journal of Chemistry, Cilt: 25 - Sayı: 2, 231–239. https://ajindex.com/articles/602404

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...