Dergiler / Turkish Journal of Medical Sciences / 2000 / Cilt: 30 - Sayı: 4

Electrochemical Biosensor Based on Horseradish Peroxidase for the Determination of Oxidizable Drugs

Sayfa
349–354
Yayın Tarihi
2022-11-04
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The stability of the HRP-modified electrode is also demonstrated.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:An amperometric biosensor based on a carbon paste electrode modified with horseradish peroxidase (HRP) is defined as a device for the quantitative and qualitative detection of oxidizable drugs.
📊
Temel Bulgular & Veri:This paper demonstrates the advantages of using HRP as the biocatalyst in the in vitro detection of oxidizable drugs in the presence of hydrogen peroxide.
💡
Sonuç & Katkı:The stability of the HRP-modified electrode is also demonstrated.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Biosensor · Amperometry · Horseradish peroxidase

Özet

An amperometric biosensor based on a carbon paste electrode modified with horseradish peroxidase (HRP) is defined as a device for the quantitative and qualitative detection of oxidizable drugs. This paper demonstrates the advantages of using HRP as the biocatalyst in the in vitro detection of oxidizable drugs in the presence of hydrogen peroxide. Amperometric analysis and batch experiments were carried out in acetate buffer (pH 4.8) in the presence of hydrogen peroxide. Amperometry was performed by applying a potential of -0.1 V (vs. Ag/AgCl), in the presence of hydrogen peroxide and adding a drug which has an oxidizable group (OxG; e.g. -OH, -NH, -SH). The results show that the HRP-modified electrode responds rapidly to micromolar changes in the OxG addition. The current signals obtained are proportional to the OxG concentration. Experimental variables, such as pH, operating potential, change in the percentage of HRP, and reproducibility are discussed. The stability of the HRP-modified electrode is also demonstrated.

Abstract

An amperometric biosensor based on a carbon paste electrode modified with horseradish peroxidase (HRP) is defined as a device for the quantitative and qualitative detection of oxidizable drugs. This paper demonstrates the advantages of using HRP as the biocatalyst in the in vitro detection of oxidizable drugs in the presence of hydrogen peroxide. Amperometric analysis and batch experiments were carried out in acetate buffer (pH 4.8) in the presence of hydrogen peroxide. Amperometry was performed by applying a potential of -0.1 V (vs. Ag/AgCl), in the presence of hydrogen peroxide and adding a drug which has an oxidizable group (OxG; e.g. -OH, -NH, -SH). The results show that the HRP-modified electrode responds rapidly to micromolar changes in the OxG addition. The current signals obtained are proportional to the OxG concentration. Experimental variables, such as pH, operating potential, change in the percentage of HRP, and reproducibility are discussed. The stability of the HRP-modified electrode is also demonstrated.

🔖

Bu Makaleye Atıf Yap

PABUÇCUOĞLU, A., ERDEM, A., KERMAN, K., ÖZSÖZ, M., MERİÇ, B. (2022). Electrochemical Biosensor Based on Horseradish Peroxidase for the Determination of Oxidizable Drugs. Turkish Journal of Medical Sciences, Cilt: 30 - Sayı: 4, 349–354. https://ajindex.com/articles/612404

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...