Dergiler / Turkish Journal of Chemistry / 2005 / Cilt: 29 - Sayı: 3

Examination of Some Organic Explosives by Ion Mobility Spectrometry (IMS)

Sayfa
255–264
Yayın Tarihi
2005-03-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Some advantages of using IMS for the detection of explosives and their residues were determined.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues.
📊
Temel Bulgular & Veri:In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,4,6-trinitrotoluene), RDX (1,3,5-trinitro-1,3,5-triazocyclohexane), PETN (pentaerythritoltetranitrate) and TETRYL (2,4,6-trinitrophenylmethylnitramine) were examined using ion mobility spectrometry (IMS).
💡
Sonuç & Katkı:Some advantages of using IMS for the detection of explosives and their residues were determined.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Explosives · ion mobility spectrometry · trace explosive evidence

Özet

The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues. In this study such an analytical method is evaluated. In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,4,6-trinitrotoluene), RDX (1,3,5-trinitro-1,3,5-triazocyclohexane), PETN (pentaerythritoltetranitrate) and TETRYL (2,4,6-trinitrophenylmethylnitramine) were examined using ion mobility spectrometry (IMS). In the second phase, qualitative analysis of a real explosion residue was carried out and the explosive material used in the bomb was identified by analysing the acetone extract. In the third phase, a handswab sample taken from a suspect was analysed for trace explosive residues. Some advantages of using IMS for the detection of explosives and their residues were determined.

Abstract

The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues. In this study such an analytical method is evaluated. In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,4,6-trinitrotoluene), RDX (1,3,5-trinitro-1,3,5-triazocyclohexane), PETN (pentaerythritoltetranitrate) and TETRYL (2,4,6-trinitrophenylmethylnitramine) were examined using ion mobility spectrometry (IMS). In the second phase, qualitative analysis of a real explosion residue was carried out and the explosive material used in the bomb was identified by analysing the acetone extract. In the third phase, a handswab sample taken from a suspect was analysed for trace explosive residues. Some advantages of using IMS for the detection of explosives and their residues were determined.

🔖

Bu Makaleye Atıf Yap

KOYUNCU, H., SEVEN, E., ÇALIMLI, A. (2005). Examination of Some Organic Explosives by Ion Mobility Spectrometry (IMS). Turkish Journal of Chemistry, Cilt: 29 - Sayı: 3, 255–264. https://ajindex.com/articles/185435

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. T.W. Carr Plasma Chromatography, Plenum Press, New York, (1984). M.J. Cohen and F.W. Karasek J. Chromatogr. Sci., 49, 330, (1970). R.H. St. Louis and H.H. Hill Critical Reviews in Anal. Chem., 5, 321, (1990). R.Wilson and A. Brittain Royal Society of Chemistry, 203, 92-101, (1997). Anonymous Ionscan Model 400 Operator’s Manual, Barringer Instruments, Canada, (1996). H. Koyuncu H. Ceylan M. Koyuncu and A. C¸ alımlı XIV. Ulusal Kimya Kongresi, 21, 10-15 Eyl¨ul, Diyarbakır, T¨urkiye, (2000). D.D. Fetterolf and T.D. Clark Journal of Forensic Sciences, JFSCA, 38, 28-39, (1993). L.L. Danylewych-May and C. Cumming 4th International Symposium on Analysis and Detection of Explosives, 385-401, September 7-10,
  2. Jerusalem, Israel, (1992). H. Koyuncu H. Ceylan M. Koyuncu and A. C¸ alımlı XIV. Ulusal Kimya Kongresi, 355, 10-15 Eyl¨ul, Diyarbakır, T¨urkiye, (2000). H.E. Revercomb and E.A. Mason Anal Chem., 47, 970, (1975). G.A. Eiceman and Z. Karpas Ion Mobility Spectrometry, CRC Press, (1994). Z. Karpas Forensic Sci. Rev., 1, 104-119, (1989). B.J. Yelverton Journal of Energetic Materials, 6, 73-80, (1988). A.H. Lawrence and P. Neudorfl Anal. Chem., 60, 104-109, (1988). J.P. Davies L.G. Blackwood S.G. Davis L.D. Goodrich and R.A. Larson Anal. Chem., 65, 3004-3009, (1993). J. Yinon and S. Zitrin Modern Methods and Applications in Analysis of Explosives, John Wiley & Sons Ltd., England, (1993). P. Kolla J. Forensic Sci., 36, 1342-1359, (1991). A.W. Beveridge Forensic Sci. Rev., 4, 17-49, (1992). H. Koyuncu Examination of Some Organic Explosives by Gas Chromatography, Gas Chromatography- Mass Spectrometry and Ion Mobility Spectrometry, Ph. D. thesis, Y¨uz¨unc¨u Yıl University, Van, (2001).