Journals / Turkish Journal of Chemistry / 2005 / Cilt: 29 - Sayı: 3

Examination of Some Organic Explosives by Ion Mobility Spectrometry (IMS)

Pages
255–264
Publication Date
2005-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Some advantages of using IMS for the detection of explosives and their residues were determined.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues.
📊
Key Findings & Data:In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,4,6-trinitrotoluene), RDX (1,3,5-trinitro-1,3,5-triazocyclohexane), PETN (pentaerythritoltetranitrate) and TETRYL (2,4,6-trinitrophenylmethylnitramine) were examined using ion mobility spectrometry (IMS).
💡
Conclusion & Impact:Some advantages of using IMS for the detection of explosives and their residues were determined.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Explosives · ion mobility spectrometry · trace explosive evidence

Abstract

The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues. In this study such an analytical method is evaluated. In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,4,6-trinitrotoluene), RDX (1,3,5-trinitro-1,3,5-triazocyclohexane), PETN (pentaerythritoltetranitrate) and TETRYL (2,4,6-trinitrophenylmethylnitramine) were examined using ion mobility spectrometry (IMS). In the second phase, qualitative analysis of a real explosion residue was carried out and the explosive material used in the bomb was identified by analysing the acetone extract. In the third phase, a handswab sample taken from a suspect was analysed for trace explosive residues. Some advantages of using IMS for the detection of explosives and their residues were determined.

Özet

The increase in terrorist activities committed using explosives in recent years has generated the need for improved analytical methods that can accurately and quickly identify explosives and their residues. In this study such an analytical method is evaluated. In the first phase of the study, standard solutions and a standard mixture solution of TNT (2,4,6-trinitrotoluene), RDX (1,3,5-trinitro-1,3,5-triazocyclohexane), PETN (pentaerythritoltetranitrate) and TETRYL (2,4,6-trinitrophenylmethylnitramine) were examined using ion mobility spectrometry (IMS). In the second phase, qualitative analysis of a real explosion residue was carried out and the explosive material used in the bomb was identified by analysing the acetone extract. In the third phase, a handswab sample taken from a suspect was analysed for trace explosive residues. Some advantages of using IMS for the detection of explosives and their residues were determined.

🔖

Cite This Article

KOYUNCU, H., SEVEN, E., ÇALIMLI, A. (2005). Examination of Some Organic Explosives by Ion Mobility Spectrometry (IMS). Turkish Journal of Chemistry, Cilt: 29 - Sayı: 3, 255–264. https://ajindex.com/articles/185435

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. T.W. Carr Plasma Chromatography, Plenum Press, New York, (1984). M.J. Cohen and F.W. Karasek J. Chromatogr. Sci., 49, 330, (1970). R.H. St. Louis and H.H. Hill Critical Reviews in Anal. Chem., 5, 321, (1990). R.Wilson and A. Brittain Royal Society of Chemistry, 203, 92-101, (1997). Anonymous Ionscan Model 400 Operator’s Manual, Barringer Instruments, Canada, (1996). H. Koyuncu H. Ceylan M. Koyuncu and A. C¸ alımlı XIV. Ulusal Kimya Kongresi, 21, 10-15 Eyl¨ul, Diyarbakır, T¨urkiye, (2000). D.D. Fetterolf and T.D. Clark Journal of Forensic Sciences, JFSCA, 38, 28-39, (1993). L.L. Danylewych-May and C. Cumming 4th International Symposium on Analysis and Detection of Explosives, 385-401, September 7-10,
  2. Jerusalem, Israel, (1992). H. Koyuncu H. Ceylan M. Koyuncu and A. C¸ alımlı XIV. Ulusal Kimya Kongresi, 355, 10-15 Eyl¨ul, Diyarbakır, T¨urkiye, (2000). H.E. Revercomb and E.A. Mason Anal Chem., 47, 970, (1975). G.A. Eiceman and Z. Karpas Ion Mobility Spectrometry, CRC Press, (1994). Z. Karpas Forensic Sci. Rev., 1, 104-119, (1989). B.J. Yelverton Journal of Energetic Materials, 6, 73-80, (1988). A.H. Lawrence and P. Neudorfl Anal. Chem., 60, 104-109, (1988). J.P. Davies L.G. Blackwood S.G. Davis L.D. Goodrich and R.A. Larson Anal. Chem., 65, 3004-3009, (1993). J. Yinon and S. Zitrin Modern Methods and Applications in Analysis of Explosives, John Wiley & Sons Ltd., England, (1993). P. Kolla J. Forensic Sci., 36, 1342-1359, (1991). A.W. Beveridge Forensic Sci. Rev., 4, 17-49, (1992). H. Koyuncu Examination of Some Organic Explosives by Gas Chromatography, Gas Chromatography- Mass Spectrometry and Ion Mobility Spectrometry, Ph. D. thesis, Y¨uz¨unc¨u Yıl University, Van, (2001).