Dergiler / Turkish Journal of Chemistry / 2012 / Cilt: 36 - Sayı: 4

Determination of lidocaine based on electrocatalysis of a chemically modified electrode

Sayfa
593–600
Yayın Tarihi
2012-04-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor.
📊
Temel Bulgular & Veri:The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA).
💡
Sonuç & Katkı:With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Lidocaine · hemoglobin · chemically modified electrodes

Özet

The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor. The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA). According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors. With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.

Abstract

The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor. The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA). According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors. With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.

🔖

Bu Makaleye Atıf Yap

TAN, G., BOLAT, G., ONUR, M. A., ABACI, S. (2012). Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry, Cilt: 36 - Sayı: 4, 593–600. https://ajindex.com/articles/185155

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...