Journals / Turkish Journal of Chemistry / 2012 / Cilt: 36 - Sayı: 4

Determination of lidocaine based on electrocatalysis of a chemically modified electrode

Pages
593–600
Publication Date
2012-04-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor.
📊
Key Findings & Data:The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA).
💡
Conclusion & Impact:According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Lidocaine · hemoglobin · chemically modified electrodes

Abstract

The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor. The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA). According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors. With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.

Özet

The potential application of biochemically modified electrodes was investigated for construction of a drug biosensor. The electrocatalytic response of lidocaine was examined through modified electrodes using the electron transfer ability of hemoglobin (Hb) immobilized on gold film modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA). According to the results of voltammetric studies, Au/MPA/Hb electrodes exhibited high sensitivity and good electrocatalytic activity for the reduction of lidocaine, motivating us to construct drug biosensors. With this study, a new electroanalytical procedure is proposed for the determination of lidocaine level in medical applications or therapeutic formulations containing lidocaine as the active ingredient.

🔖

Cite This Article

TAN, G., BOLAT, G., ONUR, M. A., ABACI, S. (2012). Determination of lidocaine based on electrocatalysis of a chemically modified electrode. Turkish Journal of Chemistry, Cilt: 36 - Sayı: 4, 593–600. https://ajindex.com/articles/185155

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...