Titrimetric determination of anionic surfactant content in anionic/nonionic surfactant mixture solution by anionic surfactant selective electrode

Sayfa
545–555
Yayın Tarihi
2012-04-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The maximum mol ratio (n(NP-10): n(SDS)) when SDS cannot be determined in SDS/NP-10 mixture solution can be obtained.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A new polyvinyl chloride (PVC) membrane electrode for determining the concentration of sodium dodecylsulfate (SDS) based on a neutral ion pair complex of dodecyltrimethylammonium-dodecylsulfate (DTA+DS-) as ionophore is described in this paper.
📊
Temel Bulgular & Veri:The construction and characteristic performance of the PVC membrane electrode displays a Nernstian slope of --56.9 \pm 0.3 mV/decade in the concentration range of 2.0 \times 10-6 to 3.2 \times 10-3 mol L-1 and a detection limit of 1.6 \times 10-6 mol L-1.
💡
Sonuç & Katkı:The maximum mol ratio (n(NP-10): n(SDS)) when SDS cannot be determined in SDS/NP-10 mixture solution can be obtained.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Anionic surfactant selective electrode · anionic surfactant · mixture solution

Özet

A new polyvinyl chloride (PVC) membrane electrode for determining the concentration of sodium dodecylsulfate (SDS) based on a neutral ion pair complex of dodecyltrimethylammonium-dodecylsulfate (DTA+DS-) as ionophore is described in this paper. The construction and characteristic performance of the PVC membrane electrode displays a Nernstian slope of --56.9 \pm 0.3 mV/decade in the concentration range of 2.0 \times 10-6 to 3.2 \times 10-3 mol L-1 and a detection limit of 1.6 \times 10-6 mol L-1. The lifetime of the electrode is more than 3 months without showing significant change in the values of slope or linear concentration range. The electrode has wide pH range of application and short response time. The electrode shows selective response to DS- and poor response to common anions except DBS-. The electrode was used as an end point indicator electrode for the determination of SDS content in sodium dodecylsulfate/nonylphenol ethoxylates (SDS/NP-10) mixture solution by potentiometric titration using Hyamine standard solution as titrant. The maximum mol ratio (n(NP-10): n(SDS)) when SDS cannot be determined in SDS/NP-10 mixture solution can be obtained.

Abstract

A new polyvinyl chloride (PVC) membrane electrode for determining the concentration of sodium dodecylsulfate (SDS) based on a neutral ion pair complex of dodecyltrimethylammonium-dodecylsulfate (DTA+DS-) as ionophore is described in this paper. The construction and characteristic performance of the PVC membrane electrode displays a Nernstian slope of --56.9 \pm 0.3 mV/decade in the concentration range of 2.0 \times 10-6 to 3.2 \times 10-3 mol L-1 and a detection limit of 1.6 \times 10-6 mol L-1. The lifetime of the electrode is more than 3 months without showing significant change in the values of slope or linear concentration range. The electrode has wide pH range of application and short response time. The electrode shows selective response to DS- and poor response to common anions except DBS-. The electrode was used as an end point indicator electrode for the determination of SDS content in sodium dodecylsulfate/nonylphenol ethoxylates (SDS/NP-10) mixture solution by potentiometric titration using Hyamine standard solution as titrant. The maximum mol ratio (n(NP-10): n(SDS)) when SDS cannot be determined in SDS/NP-10 mixture solution can be obtained.

🔖