Dergiler / Meandros Medical And Dental Journal / 2026 / Volume: 27 Issue: 2

İmplant Açısının ve Ti-Base Dayanak Yüksekliğinin Monolitik Zirkonya Kron Retansiyonu Üzerine Etkisi

The Effect of Implant Angle and Ti-Base Abutment Height on Monolithic Zirconia Crown Retention

Ceren Kendirli(LOKMAN HEKIM UNIVERSITY, FACULTY OF DENTISTRY)0000-0002-8409-9284
Hamiyet Güngör(LOKMAN HEKIM UNIVERSITY, FACULTY OF DENTISTRY)0000-0001-7449-6297
Mehmet Ali Kılıçarslan(ANKARA UNIVERSITY, FACULTY OF DENTISTRY, DENTISTRY PR.)0000-0002-8619-957X
Lale Karaağaçlıoğlu(LOKMAN HEKIM UNIVERSITY, FACULTY OF DENTISTRY)0000-0002-7382-9843
Sayfa
—
Yayın Tarihi
2026-06-24
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular Düz ve açılı konfigürasyonlar arasında, 3.5mm Ti-base boyuna sahip dayanak gruplarında istatistiksel olarak anlamlı bir fark bulunmamaktadır (p > 0.05).

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç Bu çalışma, düz ve 15 derecelik açıyla yerleştirilen implantlarda farklı ti-base yükseklikleri kullanmanın retansiyon üzerindeki etkisini araştırmayı amaçlamıştır.
📊
Temel Bulgular & Veri:Materyal ve Metod İmplant analogları, akrilik bloklara 0 derece ve 15 derece olmak üzere 2 farklı açıyla yerleştirildi. 30 adet 5.5 mm, 30 adet 3.5 mm uzunluğunda ti-base dayanak için her grupta 15 adet olacak şekilde toplamda 60 adet monolitik zirkonya kron örneği üretildi.
💡
Sonuç & Katkı:Bulgular Düz ve açılı konfigürasyonlar arasında, 3.5mm Ti-base boyuna sahip dayanak gruplarında istatistiksel olarak anlamlı bir fark bulunmamaktadır (p > 0.05).
🔬Tür:Research Article
📍Kapsam:30 adet
⚙️Değişkenler:Dental Implant Abutment · Prosthetic Dentistry · Dental Prosthesis

Özet

Amaç Bu çalışma, düz ve 15 derecelik açıyla yerleştirilen implantlarda farklı ti-base yükseklikleri kullanmanın retansiyon üzerindeki etkisini araştırmayı amaçlamıştır. Materyal ve Metod İmplant analogları, akrilik bloklara 0 derece ve 15 derece olmak üzere 2 farklı açıyla yerleştirildi. 30 adet 5.5 mm, 30 adet 3.5 mm uzunluğunda ti-base dayanak için her grupta 15 adet olacak şekilde toplamda 60 adet monolitik zirkonya kron örneği üretildi. Numuneler ti-base dayanaklara simante edildikten sonra, çekme testi için üniversal test makinesine yerleştirildi. Simantasyon başarısızlığı sırasında kullanılan maksimum kuvvet newton (N) cinsinden kaydedildi. İstatistiksel analiz, dört farklı grup arasında Maksimum Load (N) açısından anlamlı bir fark olup olmadığını test etmek için Welch ANOVA testiyle, varyans homojenliği sağlanmadığı için Tamhane T2 post-hoc testi analizi kullanılarak gerçekleştirilmiştir. Bulgular Düz ve açılı konfigürasyonlar arasında, 3.5mm Ti-base boyuna sahip dayanak gruplarında istatistiksel olarak anlamlı bir fark bulunmamaktadır (p > 0.05). Bu iki grubun karşılaştırılması dışında, diğer grup çiftleri arasında retansiyon kuvveti anlamlı derecede fark göstermiştir. Sonuç Açılı veya düz implantlarla kullanılan ti-base dayanaklı monolitik zirkonya restorasyonlarda; uzun ti-base dayanak boyuna sahip gruplar kron retansiyonu önemli düzeyde etkilerken, kısa ti-base dayanak boyuna sahip gruplar kronun retansiyonuna katkı sağlamamıştır. Protetik alan göz önünde bulundurularak en uzun Ti-base dayanak yüksekliğinin seçilmesi restorasyonun yerinden çıkma riskini minimuma indirebilir.

Abstract

Objective This study aimed to investigate the effect of using different ti-base heights on retention in implants placed at 0 degrees and 15 degrees. Material and methods Implant analogs were placed in acrylic blocks at two different angles: 0 degrees and 15 degrees. A total of 60 monolithic zirconia crown specimens were produced, with 15 specimens in each group for 30 specimens with a 5.5 mm ti-base support and 30 specimens with a 3.5 mm ti-base support. After the specimens were cemented to the ti-base supports, they were placed in a universal testing machine for a pull-out test. The maximum force used during cementation failure was recorded in newtons (N). Statistical analysis was performed using Welch's ANOVA test to test for a statistically significant difference in Maximum Load (N) between the four different groups, and the Tamhane T2 post-hoc test analysis was used since variance homogeneity was not achieved. Results There was no statistically significant difference between the straight and angled configurations in the abutment groups with a 3.5 mm Ti-base length (p > 0.05). Apart from the comparison of these two groups, the retention force showed a significant difference between the other group pairs. Conclusions In monolithic zirconia restorations supported by Ti-base abutments used with angled or straight implants, groups with longer Ti-base abutment lengths significantly affected crown retention, while groups with shorter Ti-base abutment lengths did not contribute to crown retention. Considering the prosthetic field, selecting the longest Ti-base support height may minimize the risk of restoration dislodgement.

🔖

Bu Makaleye Atıf Yap

Kendirli, C., Güngör, H., Kılıçarslan, M. A., Karaağaçlıoğlu, L. (2026). İmplant Açısının ve Ti-Base Dayanak Yüksekliğinin Monolitik Zirkonya Kron Retansiyonu Üzerine Etkisi. Meandros Medical And Dental Journal, Volume: 27 Issue: 2. https://doi.org/10.69601/meandrosmdj.1789538

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (25)

  1. Şen N, Us YÖ. İmplant destekli sabit protetik restorasyonlar için dayanak seçimi. Turkiye Klinikleri J Dent Sci. 2019;25(1):104-12.
  2. Hsiao CC, Liang CH, Shen YF, Hsu KW. Retrospective comparison of posterior fixed dental prostheses supported by two different titanium abutments on tissue level implants. J Prosthet Dent. 2021 Jun;125(6):877-882.
  3. Diken Türksayar AA, Kanpalta B, Bulucu NB, Schulnig S, Spintzyk S, Demirel M, et al. Marginal gap of printed, milled, and heat-pressed two-piece polyetheretherketone abutments before and after thermal cycling, and their pull-off bond strength after thermal cycling. J Prosthodont. 2025 Apr 2.
  4. Pitta J, Burkhardt F, Mekki M, Fehmer V, Mojon P, Sailer I. Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging. J Prosthet Dent. 2021 Aug;126(2):214-221.
  5. AlSuhimi IA, AlMudhi SA, AlMutairi ZS, Balhaddad AA, Alalawi H, Al-Dulaijan YA, et al. Marginal gap, internal fit, and fracture resistance of screw-retained single implant crowns cemented to titanium base abutments: An in vitro investigation. J Prosthodont. 2025 Oct 26.
  6. Lim HC, Kim S, Kim DH, Herr Y, Chung JH, Shin SI. Factors affecting maxillary sinus pneumatization following posterior maxillary tooth extraction. J Periodontal Implant Sci. 2021 Aug;51(4):285-295.
  7. Leung M, Alghamdi R, Guallart IF, Bergamini M, Yu PY, Froum SJ, et al. Patient-Related Risk Factors for Maxillary Sinus Augmentation Procedures: A Systematic Literature Review. Int J Periodontics Restorative Dent. 2021 May-Jun;41(3):e121-e128.
  8. Anastasaki A, Bora P, Kourtis S, Fu CC. The Effect of Zirconia Material and the Height of the Ceramic Coping on the Strength of Hybrid Ti-Ceramic Abutments. Dent J (Basel). 2025 Jun 23;13(7):284.
  9. Linkevicius T, Vaitelis J. The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis. Clin Oral Implants Res. 2015 Sep;26 Suppl 11:139-47.
  10. Gönül O, Çicek A, Afat İM, Akdoğan ET, Atalı O. Biomechanical Comparison of Asymmetric Implant Configurations for All-on-Four Treatment Using Three-Dimensional Finite Element Analysis. Life (Basel). 2022 Nov 23;12(12):1963.
  11. Pellizzer EP, Falcón-Antenucci RM, de Carvalho PS, Sánchez DM, Rinaldi GA, de Aguirre CC, et al. Influence of implant angulation with different crowns on stress distribution. J Craniofac Surg. 2011 Mar;22(2):434-7.
  12. Lin CL, Wang JC, Ramp LC, Liu PR. Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. Int J Oral Maxillofac Implants. 2008 Jan-Feb;23(1):57-64.
  13. Nguyen O, Lee SJ, Lee JD. Influence of varying titanium base abutment heights on retention of zirconia restorations: An in vitro study. J Prosthet Dent. 2023 Oct;130(4):604.e1-604.e5.
  14. Alseddiek A, Al-Zordk W, Attia A. Retention of hybrid-abutment-crowns with offset implant placement: influence of Crown materials and Ti-base height. BMC Oral Health. 2023 Oct 24;23(1):784. doi: 10.1186/s12903-023-03490-1. Erratum in: BMC Oral Health. 2024 Feb 7;24(1):202.
  15. Silva CEP, Soares S, Machado CM, Bergamo ETP, Coelho PG, Witek L, et al. Effect of CAD/CAM Abutment Height and Cement Type on the Retention of Zirconia Crowns. Implant Dent. 2018 Oct;27(5):582-587.
  16. Bonyatpour M, Giti R, Erfanian B. Implant angulation and fracture resistance of one-piece screw-retained hybrid monolithic zirconia ceramic restorations. PLoS One. 2023 Jan 23;18(1):e0280816.
  17. Zahoui A, Bergamo ET, Marun MM, Silva KP, Coelho PG, Bonfante EA. Cementation Protocol for Bonding Zirconia Crowns to Titanium Base CAD/CAM Abutments. Int J Prosthodont. 2020 Sep/Oct;33(5):527-535.
  18. D'haese R, Vervack V, Tytgat M, Vandeweghe S. Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot study. Clin Implant Dent Relat Res. 2024 Jun;26(3):615-620.
  19. Totou D, Naka O, Mehta SB, Banerji S. Esthetic, mechanical, and biological outcomes of various implant abutments for single-tooth replacement in the anterior region: a systematic review of the literature. Int J Implant Dent. 2021 Sep 8;7(1):85.
  20. Rammelsberg P, Klotz AL. Long-term retention and survival of cemented implant-supported zirconia and metal-ceramic single crowns: A retrospective study. Clin Oral Implants Res. 2024 Oct;35(10):1335-1342.
  21. Prpic V, Kosec P, Skec S, Catic A. Influence of Design Parameters on Implant Abutment Performance: A Scoping Review. J Funct Biomater. 2025 Sep 11;16(9):342.
  22. Katsavochristou A, Sierraalta M, Saglik B, Koumoulis D, George F, Razzoog M. Implant Angulation Effect on the Fracture Resistance of Monolithic Zirconia Custom Abutments: An In Vitro Study. J Prosthodont. 2020 Jun;29(5):394-400.
  23. Bagegni A, Borchers J, Beisel S, Patzelt SBM, Vach K, Kohal R. Bonding Strength of Various Luting Agents between Zirconium Dioxide Crowns and Titanium Bonding Bases after Long-Term Artificial Chewing. Materials (Basel). 2023 Nov 24;16(23):7314. doi: 10.3390/ma16237314. PMID: 38068058; PMCID: PMC10707355.
  24. Banik RK. Effect on the fracture resistance of monolithic zirconia custom abutment in different angulation: an in vitro study. Eur J Dent Oral Health. 2023;4(3):18-21.
  25. Blender SM, Mellinghoff J, Gröller SB, Schnutenhaus S, Kuhn K, Luthardt RG, et al. Effects of abutment height and type of cements on bond strength of monolithic zirconia single crowns luted to one-piece zirconia implants. Int J Prosthodont. 2022 July/August;35(4):442–452.