Journals / Hittite Journal of Science and Engineering / 2023 / Cilt: 10 Sayı: 3

Energy, Exergy, and Environment Performance Evaluation of Cascade Refrigeration System with Natural Refrigerants

Pages
243–248
Publication Date
2023-09-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

By the rise in the evaporator temperature, energy consumption decreases and as a result, the amount of carbon dioxide emissions reduced was attained.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Cascade refrigeration systems are preferred in applications where low temperature cooling is required, such as in some special industrial and laboratory applications.
📊
Key Findings & Data:In this study, two cascade systems consisting of R744/R290 (System 1) and R1270/R290 (System 2) natural refrigerant pairs were designed and thermodynamically examined.
💡
Conclusion & Impact:By the rise in the evaporator temperature, energy consumption decreases and as a result, the amount of carbon dioxide emissions reduced was attained.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Cascade refrigeration system · R744 · R1270

Abstract

Cascade refrigeration systems are preferred in applications where low temperature cooling is required, such as in some special industrial and laboratory applications. Since, in these systems, the energy consumed by the compressors is less and the compressor outlet temperature is lower. Due to environmental problems, the use of natural refrigerants in cascade refrigeration systems has become to be of great importance. In this study, two cascade systems consisting of R744/R290 (System 1) and R1270/R290 (System 2) natural refrigerant pairs were designed and thermodynamically examined. In the analyzes performed according to different evaporator temperatures, the highest COP value was 3.66 at -20℃ evaporating temperature was obtained in the cascade system consisting of the R1270/R290 refrigerant pair. Moreover, it was considered that there was a 17.95% enhancement in exergy efficiency with the use of R1270 refrigerant in the low temperature cycle. By the rise in the evaporator temperature, energy consumption decreases and as a result, the amount of carbon dioxide emissions reduced was attained.

🔖

Cite This Article

KOŞAN, M. (2023). Energy, Exergy, and Environment Performance Evaluation of Cascade Refrigeration System with Natural Refrigerants. Hittite Journal of Science and Engineering, Cilt: 10 Sayı: 3, 243–248. https://ajindex.com/articles/966268

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Coulomb A, Dupon D, Pichard JL. The Role of Refrigeration in the Global Economy-29th Informatory Note on Refrigeration Technologies. International Institute of Refrigeration, Paris,France (2015)
  2. Catalan-Gil Jesús, Sanchez LR, Andres D, Ramon LC. Energy analysis of dedicated and integrated mechanical subcooled CO2 boosters for supermarket applications. International Journal of Refrigeration 101 (2019) 11–23
  3. Nicola GD, Polonara F, Stryjek R, Arteconi A. Performance of Cascade Cycles Working with Blends of CO2 Natural Refrigerants. International Journal of Refrıgeration 34 (2011) 1436-1445
  4. Demirci E, Ozkaymak M, Kosan M, Akkoc AE, Aktas M. Doğal Soğutucu Akışkan Kullanımında Gelişmeler. Gazi Journal of Engineering Sciences 6(3) (2020) 184-199
  5. Abas N, Kalair AR, Khan N, Haider A, Saleem Z, Saleem MS. Natural and synthetic refrigerants, global warming: a review. Renewable Sustainable Energy Reviews 90 (2018) 557–569
  6. Luiz HPM, Raiza BCN, Stella MRC, Hugo VA, José VHA. Thermodynamic performance evaluation of a cascade refrigeration system with mixed refrigerants: R744/R1270, R744/R717 and R744/ RE170. International Journal of Refrigeration 106 (2019) 201-212
  7. Kasi P, Cheralathan, M. Performance analysis of cascade refrigeration system with alternative refrigerants to reduce carbon emission. Journal of Thermal Analysis and Calorimetry 148 (2023) 4389–4399
  8. Mofrad KG, Zandi S, Salehi G, Manesh MHK. 4E analyses and multi-objective optimization of cascade refrigeration cycles with heat recovery system. Thermal Science and Engineering Progress 19 (2020) 100613
  9. Soni S, Mishra P, Maheshwari G, Verma DS. Theoretical estimation of efficiency defect in cascade refrigeration system using low global warming potential refrigerant pair. Materials Today: Proceedings 59(1) (2022) 1040-1044
  10. Ozyurt A, Erdonmez N, Yılmaz B, Yılmaz D, Sevindir MK, Mancuhan E. CO2/NH3 kaskat soğutma sisteminin termodinamik analizi ve performans değerlendirmesi
  11. Ulusal Tesisat Mühendisliği Kongresi, İzmir, (2015) 1101-1110
  12. Sun Z, Liang Y, Liu S, Ji W, Zang R, Liang R, Guo Z. Comparative analysis of thermodynamic performance of a cascade refrigeration system for refrigerant couples R41/R404A and R23/R404A. Applied Energy 184 (2016) 19-25
  13. Silva AD, Filho EPB, Antunes AHP. Comparison of a R744 Cascade Refrigeration System with R404A and R22 Conventional Systems or Supermarkets. Applied Thermal Engineering 41(2012) 30-35
  14. Huang C, Li Z, Ye Z, Wang R.