Journals / Current Research in Dental Sciences / 2020 / Cilt: 30 Sayı: 1

FARKLI POLİMERİZASYON TEKNİKLERİNİN KOMPOZİT REZİNLERİN MEKANİK VE FİZİKSEL ÖZELLİKLERİNE ETKİSİ

Pages
26–32
Publication Date
2020-01-15
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Keywords: composite resin, mechanical properties, polymerization technique polimerizasyon tekniği polimerizasyon tekniği

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Bu çalışmanın amacı, direkt veya indirekt polimerizasyon teknikleri ile polimerize edilmiş farklı kompozit rezinlerin mikrosertlik, bükülme dayanımı, su emilimi ve çözünürlüklerini değerlendirmektir.
📊
Key Findings & Data:Materyal ve Metot: Rezin matriksine göre sınıflandırılan 3 kompozit rezin seçildi: U200 (3M ESPE), Grandio (VOCO), Xtrafil (VOCO).
💡
Conclusion & Impact:Keywords: composite resin, mechanical properties, polymerization technique polimerizasyon tekniği polimerizasyon tekniği
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:ompozit rezin · mekanik özellikler

Özet

Amaç: Bu çalışmanın amacı, direkt veya indirekt polimerizasyon teknikleri ile polimerize edilmiş farklı kompozit rezinlerin mikrosertlik, bükülme dayanımı, su emilimi ve çözünürlüklerini değerlendirmektir. Materyal ve Metot: Rezin matriksine göre sınıflandırılan 3 kompozit rezin seçildi: U200 (3M ESPE), Grandio (VOCO), Xtrafil (VOCO). Kompozit rezinler polimerizasyon tekniğine göre üç alt gruba ayrıldı: LED (Eliapar, 3M ESPE), LED+ indirekt ışık (DI 500 Coltene) , indirekt ışık+ısı+basınç (Tescera ATL, Bisco Dental). Her bir alt grup için yedi dikdörtgen örnek (25mm x 2mm x 2mm) yapıldı ve bükülme dayanım değerleri için üç nokta büküm testleri yapıldı. Vickers sertliğini, su emme derecesini ve çözünürlüğünü belirlemek için yedi silindirik örnek (çap: 8mm, kalınlık: 2mm) yapıldı. Silindirik örnekler 37 ° C'de 24 saat boyunca distile suda saklandı ve mikrosertlik değerleri bir Vickers sertlik test cihazı ile ölçüldü. Su emilim testi için hazırlanan örnekler 24 saat aynı koşullarda depolandı ve su emme değerleri ölçüldü. Aynı örnekler desikatörde sabit kütle elde edilinceye kadar kurutuldu ve çözünürlük ölçümleri yapıldı. Veriler iki yönlü ANOVA ve Tukey's post-hoc testi (α = 0.05) ile analiz edildi. Bulgular: Polimerizasyon teknikleri ile kompozit rezinler arasındaki etkileşim yalnızca bükülme dayanım değerlerinde anlamlı idi (p <0.05).Bükülme dayanımı, mikrosertlik ve su absorpsiyonu için en yüksek değer LED+indirekt ışıkla polimerize edilen örneklerde görüldü. Çözünürlük için en yüksek değer ise, indirekt ışık+ısı+basınçla polimerize edilen örneklerde görüldü. Sonuç: İndirekt polimerizasyon yöntemi kompozit rezinlerin mikro sertlik ve bükülme dayanımı değerlerini geliştirdi ancak su emilimi ve çözünürlük değerlerini olumsuz etkiledi. Anahtar kelimeler: Kompozit rezin, mekanik özellikler, polimerizasyon tekniği Effect of different polymerization techniques on mechanical and physical properties of composite resins Abstract Aim: The aim of this study was to evaluate the flexural strength, microhardness, water sorption and solubility of different composite resins polymerized with direct and indirect polymerization techniques. Materials and Methods: Three composit resines, classified according to their resin matrix, were selected: U200 (3M ESPE), Grandio (VOCO), Xtrafil (VOCO). Composite resins were divided into three subgroups according to polymerization technique: LED (Eliapar, 3M ESPE), LED + indirect light (DI 500 Coltene), indirect light +heat + pressure (Tescera ATL, Bisco Dental). Seven rectangular specimens (25mmx2mmx2mm) of each subgroup were prepared and 3-point bending tests were performed for flexural strength values. To determine Vickers hardness, water sorption and solubility tests; seven cylindrical specimens (diameter: 8mm thickness: 2mm) were prepared. The cylindrical specimens were stored in distilled water for 24 hours at 37◦C, and the microhardness values were measured with a Vickers hardness tester. Then, specimens were stored in the same conditions for 24 hours and water sorption values were measured. The same specimens were kept in desiccators and dried for solubility measurements until constant mass was achieved. Data were analyzed by two-way ANOVA and Tukey's post-hoc test (α=0.05). Results: The interaction between polymerization techniques and composite resins was significant only in flexural strength values (p<0.05). The highest values were obtained for flexural strength, microhardness and water sorption with indirect light and for solubility with indirect light+heat+pressure. Keywords: composite resin, mechanical properties, polymerization technique polimerizasyon tekniği polimerizasyon tekniği

🔖

Cite This Article

YAPAR, M. İ., ÇELİK, N., SAĞSÖZ, Ö., KARALAR, B., SEVEN, N., BAYINDIR, Y. Z. (2020). FARKLI POLİMERİZASYON TEKNİKLERİNİN KOMPOZİT REZİNLERİN MEKANİK VE FİZİKSEL ÖZELLİKLERİNE ETKİSİ. Current Research in Dental Sciences, Cilt: 30 Sayı: 1, 26–32. https://ajindex.com/articles/900980

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Cobb DS, MacGregor KM, Vargas MA, Denehy GE. The physical properties of packable and conventional posterior resin-based composites: a comparison. Journal of the American Dental Association, 2000, 131: 1610-1615
  2. Bayne SC, Heymann HO, Swift EJ, Jr. Update on dental composite restorations. Journal of the American Dental Association, 1994, 125: 687-701
  3. Braem M, Lambrechts P, Van Doren V, Vanherle G. The impact of composite structure on its elastic response. Journal of Dental Research, 1986, 65: 648-653
  4. Manhart J, Kunzelmann KH, Chen HY, Hickel R. Mechanical properties of new composite restorative materials. Journal of Biomedical Materials Research, 2000, 53: 353-361
  5. Poskus LT, Placido E, Cardoso PE. Influence of placement techniques on Vickers and Knoop hardness of class II composite resin restorations. Dental Materials, 2004, 20: 726-732
  6. Cook WD. Factors affecting the depth of cure of UV-polymerized composites. Journal of Dental Research, 1980, 59: 800-808
  7. Sideridou ID, Karabela MM, Bikiaris DN. Aging studies of light cured dimethacrylate-based dental resins and a resin composite in water or ethanol/water. Dental Materials, 2007, 23: 1142-1149
  8. Pala K, Tekce N, Tuncer S, Demirci M, Oznurhan F, Serim M. Flexural strength and microhardness of anterior composites after accelerated aging. J Clin Exp Dent, 2017, 9: e424-e430
  9. Alander P, Lassila LV, Tezvergil A, Vallittu PK. Acoustic emission analysis of fiber-reinforced composite in flexural testing. Dental Materials, 2004, 20: 305-312
  10. Lassila LV, Nohrstrom T, Vallittu PK. The influence of short-term water storage on the flexural properties of unidirectional glass fiber-reinforced composites. Biomaterials, 2002, 23: 2221-2229
  11. Santos C, Clarke RL, Braden M, Guitian F, Davy KWM. Water absorption characteristics of dental composites incorporating hydroxyapatite filler. Biomaterials, 2002, 23: 1897-1904
  12. Sindel J, Frankenberger R, Kramer N, Petschelt A. Crack formation of all-ceramic crowns dependent on different core build-up and luting materials. J Dent, 1999, 27: 175-181
  13. Momoi Y, Mccabe JF. Hygroscopic Expansion of Resin-Based Composites during 6 Months of Water Storage. Br Dent J, 1994, 176: 91-96
  14. Ortengren U, Andersson F, Elgh U, Terselius B, Karlsson S. Influence of pH and storage time on the sorption and solubility behaviour of three composite resin materials. J Dent, 2001, 29: 35-41
  15. Souza RO, Ozcan M, Michida SM, de Melo RM, Pavanelli CA, Bottino MA