Journals / ADO Klinik Bilimler Dergisi / 2022 / Cilt: 11 Sayı: 2

Evaluatıon of Translucency Parameter of Different Thickness of two CAD/CAM Materials

İki Farklı CAD/CAM Materyalinin Farklı Kalınlıklarda Translusensi Özelliğinin Değerlendirilmesi

Pages
115–122
Publication Date
2022-05-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The tested resin-nano-ceramic (CERASMART) samples exhibited higher TP values than the lithium disilicate-reinforced glass ceramic samples in the same thickness groups.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:ABSTRACT Aim: The aim of this study was to evaluate the optical properties of 4 different thicknesses of two different lithium disilicate glass ceramic and resin nano ceramic CAD/CAM restorative materials with the value of the translucency parameter.
📊
Key Findings & Data:Material and Methods: A total of 80 disks, specimens were prepared from high translucency (HT) A1 color lithium disilicate glass ceramic (IPS e.max® CAD, Ivoclar Vivadent, Lihtenstein) and resin nano-ceramic (CERASMART™ CAD, GC, Tokyo, Japonya) CAD/CAM blocks at 0.5 mm, 1 mm, 1.5 mm, and 2 mm thicknesses (n=10) (14x12 mm2).
💡
Conclusion & Impact:The tested resin-nano-ceramic (CERASMART) samples exhibited higher TP values than the lithium disilicate-reinforced glass ceramic samples in the same thickness groups.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:CAD/CAM cam-seramik materyal · CAD/CAM rezin-seramik materyal · Spektrofotometre

Abstract

ABSTRACT Aim: The aim of this study was to evaluate the optical properties of 4 different thicknesses of two different lithium disilicate glass ceramic and resin nano ceramic CAD/CAM restorative materials with the value of the translucency parameter. Material and Methods: A total of 80 disks, specimens were prepared from high translucency (HT) A1 color lithium disilicate glass ceramic (IPS e.max® CAD, Ivoclar Vivadent, Lihtenstein) and resin nano-ceramic (CERASMART™ CAD, GC, Tokyo, Japonya) CAD/CAM blocks at 0.5 mm, 1 mm, 1.5 mm, and 2 mm thicknesses (n=10) (14x12 mm2). The surfaces of the test samples were grinded with 600, 800 and 1200 grain silicon carbide abrasives under water cooling. After ultrasonic cleaning, the thicknesses of the test samples were checked with a digital caliper. Crystallization and glazing process was performed on the outer surfaces of the lithium disilicate glass ceramic samples, and the outer surfaces of the resin nano-ceramic samples were polished by polishing paste with the help of silicon discs. After glazins and polishing process were completed, the thicknesses of the samples were rechecked and the color measurements of the test samples were performed with a clinical spectrophotometer (VITA Easyshade® V). All samples were evaluated on white and black backgrounds for the determination of the translucency parameter (TP) according to the CIE L*a*b* system. The spectrophotometer was calibrated before each measurement. Measurements were repeated 3 times for each sample and the average of the measurements was calculated. Results: There were a statistically significant difference in TP measurement between different thicknesses in all variables (p<0.05). A statistically significant difference was found in TP measurement between different materials in all variables (p<0.05). Conclusion: All test samples were significantly affected by the thickness. TP values were decreased when the thickness of the test specimens were increased. The tested resin-nano-ceramic (CERASMART) samples exhibited higher TP values than the lithium disilicate-reinforced glass ceramic samples in the same thickness groups.

Özet

Amaç: İki farklı CAD/CAM restoratif materyalin 4 farklı kalınlıkta optik özelliklerini translusensi parametre değeri ile değerlendirmektir.

🔖

Cite This Article

HWİDİ, M. A., ÜÇTAŞLI, M. B. (2022). Evaluatıon of Translucency Parameter of Different Thickness of two CAD/CAM Materials. ADO Klinik Bilimler Dergisi, Cilt: 11 Sayı: 2, 115–122. https://ajindex.com/articles/898703

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Chaiyabutr Y, Kois JC, LeBeau D, Nunokawa G. Effect of abutment tooth color, cement color, and ceramic thickness on the resulting optical color of a CAD/CAM glass-ceramic lithium disilicate-reinforced crown. J Prosthet Dent. 2011;105(2):83–90
  2. Wahba MM, Sherif AH, El-Etreby AS, Morsi TS. The effect of different surface treatments on color and translucency of bilayered translucent nano-crystalline zirconia before and after accelerated aging. Brazilian Dent Sci. 2019;22(2):203–12
  3. Hassan SZ, Fathelbab E, Shalaby MM. The effeCT Of LUTINg AgeNT ShADeS AND ThICkNeSS Of hybRID CeRAmICS ON The PeRCeIveD fINAL COLOR. Dent J. 2018;64(53):60
  4. Duarte S, Sartori N, Phark J-H. Ceramic-reinforced polymers: CAD/CAM hybrid restorative materials. Curr Oral Heal Reports. 2016;3(3):198–202
  5. Pecho OE, Ghinea R, Ionescu AM, Cardona JC, Della Bona A, del Mar Pérez M. Optical behavior of dental zirconia and dentin analyzed by Kubelka–Munk theory. Dent Mater. 2015;31(1):60–7
  6. Hoorizad M, Valizadeh S, Heshmat H, Tabatabaei SF, Shakeri T. Influence of resin cement on color stability of ceramic veneers: in vitro study. Biomater Investig Dent. 2021;8(1):11–7
  7. Acar O, Yilmaz B, Altintas SH, Chandrasekaran I, Johnston WM. Color stainability of CAD/CAM and nanocomposite resin materials. J Prosthet Dent. 2016;115(1):71–5
  8. Drummond JL, King TJ, Bapna MS, Koperski RD. Mechanical property evaluation of pressable restorative ceramics. Dent Mater. 2000;16(3):226–33
  9. KÖKAT AM, KÖKAT AD. Monolithic CAD/CAM restorations–Esthetic Zone Applications. J Exp Clin Med. 2021;38(3s):180–7
  10. Nogueira AD, Della Bona A. The effect of a coupling medium on color and translucency of CAD–CAM ceramics. J Dent. 2013;41:e18–23
  11. Wyszecki G, Stiles WS. Color science: concepts and methods, quantitative data and formulas. 1982
  12. Bayindir F, Koseoglu M. The effect of restoration thickness and resin cement shade on the color and translucency of a high-translucency monolithic zirconia. J Prosthet Dent. 2020;123(1):149–54
  13. Erdemir U, Yıldız E, Eren MM. Effects of sports drinks on color stability of nanofilled and microhybrid composites after long-term immersion. J Dent. 2012;40:e55–63
  14. Lehmann KM, Igiel C, Schmidtmann I, Scheller H. Four color-measuring devices compared with a spectrophotometric reference system. J Dent [Internet]. 2010;38(SUPPL. 2):e65–70. Available from:
  15. Paul SJ, Peter A, Rodoni L, Pietrobon N. Conventional v