Journals / Middle Black Sea Journal of Health Science / 2020 / Cilt: 6 - Sayı: 1

Influence of reciprocating NiTi instruments on the accuracy of apex locator integrated endomotors during simultaneous working length determination

Pages
70–75
Publication Date
2020-04-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

However, Counterfeit endodontic files failed to show of accurate simultaneous working length determination.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To compare simultaneous working length determination efficiency and electrical resistance of thermally treated NiTi files and their counterfeits.Methods: Access cavities were prepared for sixty human mandibular premolar teeth, which were then numbered with a marker.
📊
Key Findings & Data:Actual working length was determined visually by introducing a #10 K-file into the root canal and the reference point was marked for further steps.
💡
Conclusion & Impact:However, Counterfeit endodontic files failed to show of accurate simultaneous working length determination.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Electrical resistance · Endodontics · Nitinol

Abstract

Objective: To compare simultaneous working length determination efficiency and electrical resistance of thermally treated NiTi files and their counterfeits.Methods: Access cavities were prepared for sixty human mandibular premolar teeth, which were then numbered with a marker. Actual working length was determined visually by introducing a #10 K-file into the root canal and the reference point was marked for further steps. By using flowable composite, the teeth were fixed at the cementoenamel junction to a hole in the center of a glass bottle cap and a second hole prepared on it for lip clip. Alginate impression material was filled into glass bottle then the tooth was embedded into it. Experimental models randomly divided into 6 groups as Group WOG (WaveOne Gold), Group WO (WaveOne), Group W+ (Superline W+), Group RB (Reciproc Blue), Group R (Reciproc), Group V (Superline V). Root canals were prepared until the endomotor stopped when reaching the apical foramen and the silicon stopper was moved to the previously marked reference point to determine the simultaneous working length. The electrical resistance of the files (from tip of file to notch of the shaft) was measured using a multimeter.Results: No readings could be obtained via apex locator for Group V. Group W+ was significantly less accurate compered the other groups (p<0.05). No significant difference was found among the groups WO, WOG, R, and RB (p>0.05).Conclusion: Thermal treatments of NiTi alloys had no effect on the accuracy of simultaneous working length determination. However, Counterfeit endodontic files failed to show of accurate simultaneous working length determination.

🔖

Cite This Article

SARIYILMAZ, Ö., SARIYILMAZ, E., KESKİN, C. (2020). Influence of reciprocating NiTi instruments on the accuracy of apex locator integrated endomotors during simultaneous working length determination. Middle Black Sea Journal of Health Science, Cilt: 6 - Sayı: 1, 70–75. https://ajindex.com/articles/791144

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Arslan H, Güven Y, Karataş E, Doğanay E. Effect of the Simultaneous Working Length Control during Root Canal Preparation on Postoperative Pain. J Endod 2017
  2. 43(9): 1422–7. doi:10.1016/j.joen.2017.04.028 Gavini G, Santos MD, Caldeira CL, et al. Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res. 2018
  3. 32(suppl 1): e67. doi:10.1590/1807-3107bor-2018.vol32.0067 Hancocks S. Beware and be aware. Br Dent J 2016
  4. 220(2): 43. doi:10.1038/sj.bdj.2016.36 Nekoofar MH, Ghandi MM, Hayes SJ, Dummer PMH. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 2006
  5. 595–609. doi:10.1111/j.1365-2591.2006.01131.x Orafi I, Rushton VE. The use of radiography and the apex locator in endodontic treatment within the UK: a comparison between endodontic specialists and general dental practitioners. Int Endod J 2013
  6. 355–64. doi:10.1111/j.1365-2591.2012.02127.x Proffitt E. Counterfeit and Non-Compliant Dental Devices: The Dangers and How to Mitigate Them. Dent Update 2016
  7. 43(4): 307–12. doi:10.12968/denu.2016.43.4.307 Ricucci D, Russo J, Rutberg M, Burleson JA, Spångberg LS. A prospective cohort study of endodontic treatments of 1,369 root canals: results after 5 years. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011
  8. 112(6): 825–842. doi:10.1016/j.tripleo.2011.08.003 Rodrigues CS, Vieira VTL, Antunes HS, De-Deus G, Elias CN, Moreira EJL, Silva EJNL. Mechanical characteristics of counterfeit Reciproc instruments: a call for attention. Int Endod J 2018
  9. 556–63. doi:10.1111/iej.12792 Shen Y, Zhou HM, Zheng YF, Peng B, Haapasalo M. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod 2013
  10. 39(2): 163–172. doi:10.1016/j.joen.2012.11.005 Sipavičiūtė E, Manelienė R. Pain and flare-up after endodontic treatment procedures. Stomatologija. 2014
  11. 16(1): 25–30. Thompson SA. An overview of nickel-titanium alloys used in dentistry. Int Endod J 2000
  12. 297–310. doi:10.1046/j.1365-2591.2000.00339.x Zupanc J, Vahdat-Pajouh N, Schäfer E. New thermomechanically treated NiTi alloys - a review. Int Endod J 2018
  13. 51(10): 1088–103. doi:10.1111/iej.12924