Journals / Journal of Energy Systems / 2019 / Cilt: 3 - Sayı: 1

Design of an LLCL type filter for stand-alone PV systems’ harmonics

Pages
36–50
Publication Date
2019-03-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This paper attempts to show that the using of LLCL filter with a stand-alone solar system can highly improve the power quality of the system.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper is regarding the design, modeling and simulation for reducing harmonics with passive LLCL filter in off-grid solar system.
📊
Key Findings & Data:The simulation result shows that the reduction of THDI from 89.89% to 3.257%.
💡
Conclusion & Impact:This paper attempts to show that the using of LLCL filter with a stand-alone solar system can highly improve the power quality of the system.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:PV module model · Passive LLCL harmonic filter · Total harmonic distortion (THD)

Abstract

This paper is regarding the design, modeling and simulation for reducing harmonics with passive LLCL filter in off-grid solar system. It is desired that current and voltage waveforms are to be in the sinusoidal form during energy generation from stand-alone solar systems. This condition can be provided by the most important one of the main factors which to determine the quality of electrical energy. Due to the harmonics produced by the non-linear loads, the waveform of the current and voltage is distorted from the sinusoidal form. The passive LLCL filter is designed and analyzed for mitigation of the total harmonic distortion for current (THDI) in the proposed off-grid PV system. The passive LLCL filter is practically installed between solar inverter and non-linear load. Simulation results are in a good compliance with the theoretical analysis. This study describes a design methodology of a LLCL filter for off-grid power system with a comprehensive study of how to mitigate the harmonics in off-grid solar system. The using of a LLCL filter mitigates the THDI that injected by a six pulse rectifier which is used as a non-linear load. The simulation result shows that the reduction of THDI from 89.89% to 3.257%. This paper attempts to show that the using of LLCL filter with a stand-alone solar system can highly improve the power quality of the system.

🔖

Cite This Article

ADAK, S., CANGİ, H., YILMAZ, A. S. (2019). Design of an LLCL type filter for stand-alone PV systems’ harmonics. Journal of Energy Systems, Cilt: 3 - Sayı: 1, 36–50. https://ajindex.com/articles/776292

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Tavakoli, BM, Pashajavid, E. An efficient procedure to design passive LCL-filters for active power filters. Electric Power Systems Research, 2009, 79, 606-614. DOI: 10.1016/j.epsr.2008.08. Cheng, JH, Witulski, A. Analytic solutions for LLCC parallel resonant converter simplify use of two and three-element converters. IEEE Transactions on Power Electronics, 1998, 13, 235–243.
  2. Yilmaz, AS, Alkan, A, Asyali. MH. Applications of parametric spectral estimation methods on detection of power system harmonics. Electric Power Systems Research, 2008, 78, 683-693. Doi.org/10.1016/j.epsr.2007.05.011. Rüstemli S, Okuducu E, and Efe SB. Elektrik Tesislerinde Harmoniklerin Pasif Filtre Kullanılarak Azaltılması ve Simulasyonu (in Turkish). In: EVK2015 6. Energy Efficiency and Quality Symposium; 4-6 June 2015: pp 120-124.
  3. Xing Z, Hong Z, Fei L, Fang L, Chun L, Benxuan L. An LCL-LC power filter for grid-tied inverter. In: TENCON IEEE Region 10 Conference; October 2013: pp. 1-4.
  4. Rashid, HM. Power Electronics, Circuits, Devices, and Applications, USA: Pearson Press, 2014.
  5. Zhou, F, Luo A, Li, Y, Xu, Q, He, Z, Guerrero, JM. Double-carrier phase-disposition pulse width modulation method for modular multilevel converters. Energies, 2017; 10: 581–704. Doi:10.3390/en10040581. Er, Z, Balci, E. Dual axis solar angle tracking system without any sensor. Journal of Energy Systems, 2018, 2, 127-136. Doi.org/10.30521/jes.379164. Kececioglu, OF, Acikgoz, H, Yildiz, C, Gani, A, Sekkeli, M. Power Quality Improvement Using Hybrid Passive Filter Configuration for Wind Energy Systems. Journal of Electrical Engineering Technology, 2017, 12, 2370-2375. DOI: 10.1016/j.sbspro.2015.06.211 Ozdemir, A, Ferikoglu, A. Low cost mixed-signal microcontroller based power measurement technique. IEE Proceedings-Science Measurement and Technology, 2004, 151, 253-258. Doi: 10.1049/ip-smt:20040242 – JUL. Cangi H, Adak S. Analysis of solar inverter THD according to PWM’s carrier frequency. In: International Conference on Renewable Energy Research and Applications (ICRERA); November 2015: DOI: 10.1109/ICRERA.2015, 7418694. Ang, Y, Bingham, C, Foster, M, Howe, D. Design oriented analysis of fourth-order LCLC converters with capacitive output filter. IEE Proceedings -Electric Power Applications, 2005, 152, 310–322, 2005. DOI: 10.1049/ip-epa:20045112 Adak, S, Cangi, H. Analysis and Simulation Total Harmonic Distortion of Output Voltage Three Level Diode Clamped Inverter in Photovoltaic System. Bitlis ErenUniversity