Journals / International Journal of Thermodynamics / 2018 / Cilt: 21 - Sayı: 2

Exergetic Investigation of a R1234yf Automotive Air Conditioning System with Internal Heat Exchanger

Pages
103–109
Publication Date
2018-05-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Moreover, it was observed that the temperature rise in the air stream decreased the exergy efficiency and increased the total exergy destruction per cooling capacity.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study presents the exergetic investigation of an automotive air conditioning (AAC) system with the refrigerant R1234yf experimentally.
📊
Key Findings & Data:An internal heat exchanger (IHX) has been added to the system in order to provide performance enhancement.
💡
Conclusion & Impact:Moreover, it was observed that the temperature rise in the air stream decreased the exergy efficiency and increased the total exergy destruction per cooling capacity.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Automobile air conditioning · exergy analysis · internal heat exchanger

Abstract

This study presents the exergetic investigation of an automotive air conditioning (AAC) system with the refrigerant R1234yf experimentally. The air-conditioning system is based on the conventional mechanical compression refrigeration cycle. An internal heat exchanger (IHX) has been added to the system in order to provide performance enhancement. The influence of the IHX investigated at different compressor speeds and air stream temperatures. Experimental measurements were collected by using a data-acquisition system, and the results were obtained by performing exergetic analysis. The exergy destruction, exergy efficiency and the total exergy destruction per cooling capacity were calculated. The analysis results were compared with a baseline system which operates with the refrigerant R134a. Furthermore, an empirical correlation was proposed for the determination of the total exergy destruction per cooling capacity for various compressor speeds for evaluating the system performance without doing further experiments. As a result, the exergetic efficiency of the system was improved by introducing IHX to the system. Moreover, it was observed that the temperature rise in the air stream decreased the exergy efficiency and increased the total exergy destruction per cooling capacity.

🔖

Cite This Article

Direk, M., Mert, M. S., Yüksel, F., Keleşoğlu, A. (2018). Exergetic Investigation of a R1234yf Automotive Air Conditioning System with Internal Heat Exchanger. International Journal of Thermodynamics, Cilt: 21 - Sayı: 2, 103–109. https://ajindex.com/articles/673498

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. R. Akasaka, K. Tanaka, Y. Higashi, “Thermodynamic Property Modelling for 2,3,3,3-tetrafluoropropene (HFO-1234yf),” International Journal of Refrigeration, 33, 52-60, 2010
  2. European Parliament and of the Council Official Journal of the European Union, “Emissions from Air Conditioning Systems in Motor Vehicles,” Directive No.2006/40/EC, EU, Brussels, 2006
  3. European Parliament and of the Council, Regulation Official Journal of the European Union, “Fluorinated greenhouse gases,” Directive No.2014/517/EU, EU, Strasbourg, 2014
  4. M. Spatz, and B. Minor, “HFO-1234yf Low-GWP Refrigerant Update,” in Proceedings of the International Refrigeration and Air Conditioning Conference, West Lafayette, Indiana, pp. 1-8, 2008
  5. M. O. McLinden, A. F. Kazakov, J. S. Brown, P. A. Domanski, “A Thermodynamic Analysis of Refrigerants: Possibilities and Tradeoffs for Low-GWP Refrigerants,” International Journal of Refrigeration, 38, 80-92, 2014
  6. C. Zilio, J. S. Brown, G. Schiochet, A. Cavallini, “The Refrigerant R1234yf in Air Conditioning Systems,” Energy, 36, 6110-6120, 2011
  7. S. Petitjean, and J. Benouali, “R-1234yf Validation & A/C System Energy Efficiency Improvements,” in Proceedings of the SAE Alternate Refrigerant Symposium, Scottsdale, Arizona, 2010
  8. Y. Lee, D. Jung, “A Brief Performance Comparison of R1234yf and R134a in a Bench Tester for Automobile Applications,” Applied Thermal Engineering, 35, 240-242, 2012
  9. J. Navarro-Esbri, J. M. Mendoza-Miranda, A. Mota-Babiloni, A. Barragan-Cervera, J. M. Belman-Flores, “Experimental Analysis of R1234yf as a Drop-in Replacement for R134a in a Vapor Compression System,” International Journal of Refrigeration, 36, 870-880, 2013
  10. D. Sanchez, R. Cabello, R. Llopis, I. Aruzaro, J. Catalan Gil, E. Torrella, “Energy Performance Evaluation of R1234yf, R1234ze(E), R600a, R290, and R152a as Low-GWP R134a Alternatives,” International Journal of Refrigeration, 74, 269-282, 2017
  11. H. S. Hamut, I. Dincer, G. F. Naterer, “Exergetic and Energetic Evaluations of Hybrid Electric Vehicle Thermal Management Systems,” International Journal of Exergy, 12, 341-363, 2014
  12. J. Navarro-Esbri, F. Moles, A. Barragan-Cervera, “Experimental Analysis of the Internal Heat Exchanger Influence on a Vapour Compression System Performance Working with R1234yf as a Drop-in Replacement for R134a,” Applied Thermal Engineering, 59, 153-161, 2013
  13. H. Cho, H. Lee, C. Park, “Performance Characteristics of an Automobile Air C