Journals / International Journal of Thermodynamics / 2022 / Cilt: 25 - Sayı: 1

Proposing an Ultrapure Water Unit Coupled to an Existing Reverse Osmosis Desalination Plant and its Exergy Analysis

Pages
39–52
Publication Date
2022-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The electro-de-ionization (EDI) and the RO unit were the highest exergy destructive components in Plant A.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, three desalination exergy analysis models including the Cerci et al. model (Model A), Drioli et al. model (Model B) and electrolyte solution model (Model C), were developed on an existing reverse osmosis (RO) desalination plant in Oman (Plant ALG).
📊
Key Findings & Data:A modified ultrapure water (UPW) unit fed by Plant ALG has also been proposed (Plant A) based on the technology used in a UPW unit operated under the climate of Europe and fed by European river water (Plant B).
💡
Conclusion & Impact:The electro-de-ionization (EDI) and the RO unit were the highest exergy destructive components in Plant A.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Revese Osmosis · Ultrapure Water · Exergy Destruction

Abstract

In this study, three desalination exergy analysis models including the Cerci et al. model (Model A), Drioli et al. model (Model B) and electrolyte solution model (Model C), were developed on an existing reverse osmosis (RO) desalination plant in Oman (Plant ALG). A modified ultrapure water (UPW) unit fed by Plant ALG has also been proposed (Plant A) based on the technology used in a UPW unit operated under the climate of Europe and fed by European river water (Plant B). The most suitable exergy model for characterizing the proposed UPW production plant was used. Model C was found to be the most proper model among its counterparts. It reflected the electrolytic behavior of the relevant streams and considered as the appropriate model. The major exergy destruction sites were also identified, and the exergy efficiency was calculated. The electro-de-ionization (EDI) and the RO unit were the highest exergy destructive components in Plant A.

🔖

Cite This Article

MAQBALİ, B. A., RAHİMİ-AHAR, Z., MOUSA, H., VAKİLİ-NEZHAAD, G. R. (2022). Proposing an Ultrapure Water Unit Coupled to an Existing Reverse Osmosis Desalination Plant and its Exergy Analysis. International Journal of Thermodynamics, Cilt: 25 - Sayı: 1, 39–52. https://ajindex.com/articles/673385

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. P. Palenzuela, B. Ortega-delgado, D. Alarcón-padilla, “Comparative assessment of the annual electricity and water production by concentrating solar power and desalination plants: A case study,” Appl. Therm. Eng., 2020:177:15485. https://doi.org/10.1016/j.applthermaleng.2020.115485.
  2. Z. Rahimi-Ahar, M. S. Hatamipour, “A perspective of thermal type desalination: Technology, current development and thermodynamics analysis,” Encyclopedia of Life Support Systems (EOLSS). http://www.eolss.net/Eolss-sampleAllChapter.aspx, 2020. K. Yousuf, 2019. “Efforts on to meet future water demand,” Available:Https://www.omanobserver.om/efforts-on-to-meet-future-water-demand/. T. M. A. Al Sajwani, “The desalination plants of Oman: past, present and future,” Desalination, 1998:120:8–13. https://doi.org/10.1016/S0011-9164(98)00201-X.
  3. Z. Rahimi-Ahar, M. S. Hatamipour, L. Rahimi Ahar, “Air Humidification-Dehumidification Process for Desalination: A review,” Prog. Energy Combust. Sci., 2020:80:100850. https://doi.org/10.1016/j.pecs.2020.100850.
  4. O. N. Igobo, P. A. Davies, “Isothermal Organic Rankine Cycle (ORC) driving Reverse Osmosis (RO) Desalination: experimental investigation and case study using R245fa working fluid,” Appl. Therm. Eng., 2018:136:740–746. https://doi.org/10.1016/j.applthermaleng.2018.02.056.
  5. M. A. Darwish, N. M. Al-najem, “Energy consumption by multi-stage flash and reverse osmosis desalters,” Appl. Therm. Eng., 2000:20:399–416. https://doi.org/10.1016/S1359-4311(99)00032-0.
  6. S. Ahmadvand, B. Abbasi, B. Azarfar, M. Elhashimi, “Looking beyond energy efficiency: an applied review of water desalination technologies and an introduction to capillary-driven desalination,” water, 2019:11:696–726. https://doi.org/10.3390/w11040696.
  7. Z. Rahimi-Ahar, M. S. Hatamipour, Y. Ghalavand, A. Palizvan, “Comprehensive study on vacuum humidification-dehumidification (VHDH) desalination,” Appl. Therm. Eng., 2020:114944. https://doi.org/10.1016/j.applthermaleng.2020.114944.
  8. F. Cziesla, G. Tsatsaronis, Exergy, energy system analysis and optimization. Strengths and limitations of exergy analysis, Inst. Energy Eng., Vol. I, Springer. 1999.
  9. F. Fitzsimons, B. Corcoran, P. Young, G. Foley, “Exergy analysis of water purification and desalination: A study of exergy model approaches,” Desalination, 2015:359:212–224. https://doi.org/10.1016/j.desal.2014.12.033. Y. Cerci, “Exergy analysis of a reverse osmosis desalination plant in California,” Desalination, 2002:142: 257–266. https://doi.org/10.10