Journals / Hittite Journal of Science and Engineering / 2022 / Cilt: 9 - Sayı: 3

One Step Fabrication of Hollow and Highly Flexible Polydimethylsiloxane Microneedles

Pages
219–224
Publication Date
2022-09-28
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Moreover, this system has the potential to be used not only for the high-throughput microfluidic fabrication of polymeric beads, but also in controlled drug delivery systems and cell encapsulation studies.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the hollow and highly flexible polydimethylsiloxane microneedles were fabricated in a one step and simple design.
📊
Key Findings & Data:For this purpose, a commercial dermastamping device (Dermastamp® 140 DRS) was used as a mold to obtain highly flexible PDMS microneedles containing channels.
💡
Conclusion & Impact:Moreover, this system has the potential to be used not only for the high-throughput microfluidic fabrication of polymeric beads, but also in controlled drug delivery systems and cell encapsulation studies.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:hollow microneedle · microfabrication · one step

Abstract

In this study, the hollow and highly flexible polydimethylsiloxane microneedles were fabricated in a one step and simple design. For this purpose, a commercial dermastamping device (Dermastamp® 140 DRS) was used as a mold to obtain highly flexible PDMS microneedles containing channels. With the proposed design, microneedles with a total height of 1500 μm, 1500 μm center-to-center spacing and 150 μm channel diameter was successfully fabricated. These data are all compatible with the dimensions and the geometry of the mold used. Then, a syringe adapter was fabricated with a 3D printer and combined with the hollow PDMS microneedle patch for the high-throughput production of alginate beads. After the adapter and the hollow PDMS microneedle patch combination was placed into the syringe pump, the mostly spherical alginate beads with a mean diameter of 2.0 ± 0.3 mm was produced. To sum up, the proposed design and fabrication scheme first offer a novel and simple strategy for the fabrication of hollow polymeric microneedles. Moreover, this system has the potential to be used not only for the high-throughput microfluidic fabrication of polymeric beads, but also in controlled drug delivery systems and cell encapsulation studies.

🔖

Cite This Article

CAKMAK, S. (2022). One Step Fabrication of Hollow and Highly Flexible Polydimethylsiloxane Microneedles. Hittite Journal of Science and Engineering, Cilt: 9 - Sayı: 3, 219–224. https://ajindex.com/articles/671586

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Prausnitz MR, Langer R. Transdermal drug delivery. Nature Biotechnology 26 (2008) 1261–1268. https://doi.org/10.1038/nbt.1504
  2. Gill HS, Prausnitz MR. Does needle size matters?. Journal of Diabetes Science and Technology 1 (2007) 725–729. https://doi.org/10.1177/193229680700100517
  3. Ingrole RSJ, Azizoglu A, Dul M, Birchall JC, Gill, HS, Prausnitz MR. Trends of microneedle technology in the scientific literature, patents, clinical trials and internet activity. Biomaterials 267 (2021) 120491 1–24. https://doi.org/10.1016/j.biomaterials.2020.120491
  4. Waghule T, Singhvi G, Dubey SK, Pandey MM, Gupta G, Singh M, Dua K. Microneedles: a smart approach and increasing potential for transdermal drug delivery system. Biomedicine & Pharmacotherapy 109 (2019) 1249–1258. https://doi.org/10.1016/j.biopha.2018.10.078
  5. Mukerjee EV, Collins SD, Isseroff RR, Smith RL. Microneedle array for transdermal biological fluid extraction and in situ analysis. Sensors and Actuators A 114 (2004) 267–275. https://doi.org/10.1016/j.sna.2003.11.008
  6. Windmiller JR, Valdes-Ramirez G, Zhou N, Zhou M, Miller PR, Jin C, Brozik SM, Polsky R, Katz E, Narayan R, Wang J. Bicomponent microneedle array biosensor for minimally-invasive glutamate monitoring. Electroanalysis 23 (2011) 2303–2309. https://doi.org/10.1002/elan.201100361
  7. Jiang X, Lillehoj PB. Microneedle-based skin patch for blood-free rapid diagnostic testing. Microsystems & Nanoengineering 6 (2020) 96 1–11. https://doi.org/10.1038/s41378-020-00206-1
  8. Resnik D, Mozek M, Pecar B, Janez A, Urbancic V, Iliescu C, Vrtacnik D. In vivo experimental study of noninvasive insulin microinjection through hollow Si microneedle array. Micromachines 9 (2018) 40 1–17. https://doi.org/10.3390/mi9010040
  9. Economidou SN, Uddin MJ, Marques MJ, Douroumis D, Sow WT, Li H, Reid A, Windmill JFC, Podoleanu A. A novel 3D printed hollow microneedle microelectromechanical system for controlled, personalized transdermal drug delivery. Additive Manufacturing 38 (2021) 101815 1–11. https://doi.org/10.1016/j.addma.2020.101815
  10. Farias C, Lyman R, Hemingway C, Chau H, Mahacek A, Bouzos E, Mobed-Miremadi M. Three-dimensional (3D) printed microneedles for microencapsulated cell extrusion. Bioengineering 5 (2018) 59 1–26. https://doi.org/10.3390/bioengineering5030059
  11. Carcamo-Martinez A, Mallon B, Dominguez-Robles J, Vora LK, Anjani QK, Donnely RF. Hollow microneedles: a perspective in biomedical applications. International Journal of Pharmaceutics 599 (2021) 120455 1–18. https://doi.or