Journals / European Archives of Medical Research / 2020 / Cilt: 36 - Sayı: 2

Surgical Treatment of Humeral Shaft Fractures by Arthroscopyassisted Intramedullary Nail Fixation

Pages
108–114
Publication Date
2022-11-06
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This technique may be a feasible and safe option associated with reduced entry site complications and potentially lessexposure to radiation from shorter use of fluoroscopy

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Humeral shaft fractures face with controversies about the entry site of intramedullary nailing (IMN) due to its potentialcomplications.
📊
Key Findings & Data:We aimed to evaluate feasibility of arthroscopy-assisted intramedullary nail fixation for the management of these fractureswith respect to its mid-term clinical and functional outcomes, complication rates of nail entry site, and fluoroscopy duration.Methods: We examined medical data of 21 patients who underwent arthroscopy-assisted IMN after closed reduction upon diagnosis ofhumeral shaft fracture.
💡
Conclusion & Impact:This technique may be a feasible and safe option associated with reduced entry site complications and potentially lessexposure to radiation from shorter use of fluoroscopy
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: Humeral shaft fractures face with controversies about the entry site of intramedullary nailing (IMN) due to its potentialcomplications. We aimed to evaluate feasibility of arthroscopy-assisted intramedullary nail fixation for the management of these fractureswith respect to its mid-term clinical and functional outcomes, complication rates of nail entry site, and fluoroscopy duration.Methods: We examined medical data of 21 patients who underwent arthroscopy-assisted IMN after closed reduction upon diagnosis ofhumeral shaft fracture. Analyzed parameters included duration of anesthesia, surgery, fluoroscopy, preoperative hospitalization, and union;surgical complication rates; and the degree of lateralization between ideal and applied nail entry site, as measured by shoulder computedtomography scans. Shoulder functions were assessed by Constant and American Shoulder and Elbow Surgeons (ASES) scoring.Results: Patients were found to be followed up for a mean of 22.8±4.76 months. The mean duration of surgery was 56.9±14.27 minutes. Themean fluoroscopy time was detected as 1.63±0.49 minutes. Distal locking was performed without fluoroscopy (electromagnetic targeting orinternal locking nail) in 15 patients and with free hand method under fluoroscopy in six patients. The mean duration of fluoroscopy in thesetechniques were 1.47±0.41 minutes and 1.91±0.52 minutes, respectively. No patient was found to have subacromial impingement syndrome.The mean lateralization of nail entry sites was measured as 0.61±0.73 mm. The mean degree of varus was 2.38±1.18. The mean ASES andConstant scores were found as 89±2.81 and 90±4.59 points,respectively. Excellent/good functional outcomes had been reported by 90.5% ofthe study population.Conclusion: Arthroscopy-assisted technique may minimize rotator cuff injury and thereby may provide satisfactory outcomes in postoperativeshoulder functions. This technique may be a feasible and safe option associated with reduced entry site complications and potentially lessexposure to radiation from shorter use of fluoroscopy

🔖

Cite This Article

BÜYÜKKURT, C. D., İMREN, Y., YÜCE, A., DEDEOĞLU, S. S., ADAŞ, M., BAYRAKTAR, T. O., GÜRBÜZ, H. (2022). Surgical Treatment of Humeral Shaft Fractures by Arthroscopyassisted Intramedullary Nail Fixation. European Archives of Medical Research, Cilt: 36 - Sayı: 2, 108–114. https://ajindex.com/articles/650411

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Updegrove GF, Mourad W, Abboud JA. Humeral Shaft Fractures. J Shoulder Elbow Surg 2018;27:87-97
  2. Fan Y, Li YW, Zhang HB, Liu JF, Han XM, Chang X, et al. Management of humeral shaft fractures with intramedullary interlocking nail versus locking compression plate. Orthopedics 2015;38:825-9
  3. Baltov A, Mihail R, Dian E. Complications after interlocking intramedullary nailing of humeral shaft fractures. Injury 2014;45(Suppl 1):9-15
  4. Pogliacomi F, Devecchi A, Costantino C, Vaienti E. Functional long-term outcome of the shoulder after antegrade intrame-dullary nailing in humeraldiaphyseal fractures. Chir Organi Mov 2008;92:11-6
  5. Hohmann E, Glatt V, Tetsworth K. Response to letter to the editor regarding “Minimally invasive plating versus either open reduction and plate fixation or intramedullary nailing of humeral shaft fractures: a systematic review and meta-analysis of randomized controlled trials”. J Shoulder Elbow Surg 2017;26:79-80
  6. Wali MG, Baba AN, Latoo IA, Bhat NA, Baba OK, Sharma S. Internal fixation of shaft humerus fractures by dynamic compression plate or interlocking intramedullary nail: a prospective, randomised study. Strategies Trauma Limb Reconstr 2014;9:133-40
  7. Mückley T, Diefenbeck M, Sorkin AT, Beimel C, Goebel M, Bühren V. Results of the T2 humeral nailing system with special focus on compression interlocking. Injury 2008;39:299-305
  8. Herbst U, Ruettger K, Mockwitz J. Experiences with the Russell-Taylor Nail in Humeral Shaft Fractures-An Analysis of Postoperative Results and Complications. Osteo Trauma Care 2003;11:13-20
  9. Franck WM, Olivieri M, Jannasch O, Hennig FF. Expandable nail system for osteoporotic humeral shaft fractures: preliminary results. J Trauma 2003;54:1152-8
  10. Persiani P, Gurzi M, Moreschini O, Di Giacomo G, Villani C. Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail. Musculoskeletal Surg 2017;101:19-23
  11. Choudhari P, Baxi M, Patidar S. Fracture Shaft Humerus: Plating OR Nailing? Orthopaedic Journal of MP Chapter 2016:22
  12. Kulkarni VS, Kulkarni MS, Kulkarni GS, Goyal V, Kulkarni MG. Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plateosteosynthesis (MIPO) in treatment of humerus diaphyseal fractures. Injury 2017;48(Suppl 2):8-13
  13. Berkes MB, Little MT, Lorich DG. Complications of Intramedullary Nailing, in Intramedullary Nailing. Springer