Journals / Türk Oftalmoloji Dergisi / 2012 / Cilt: 42 - Sayı: 2

The long-term effects of silicone hydrogel contact lens wear on corneal morphology

Silikon hidrojel kontakt lens kullanımının kornea morfolojisi üzerindeki uzun dönem etkileri

Pages
91–96
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In Group 1, the percentage of endothelial cells larger than 700μ was low, while the percentage of endothelial cells between 200 and 400μ was high (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Pur po se: To evaluate the effects of silicone hydrogel contact lenses (SHCL) on central corneal thickness (CCT), corneal endothelial cell morphology, and tear functions.
📊
Key Findings & Data:Ma te ri al and Met hod: Fifty-five eyes of 28 SHCL wearers (Group 1) and 52 eyes of 26 healthy subjects (Group 2) were included in this study’.
💡
Conclusion & Impact:In Group 1, the percentage of endothelial cells larger than 700μ was low, while the percentage of endothelial cells between 200 and 400μ was high (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Pur po se: To evaluate the effects of silicone hydrogel contact lenses (SHCL) on central corneal thickness (CCT), corneal endothelial cell morphology, and tear functions. Ma te ri al and Met hod: Fifty-five eyes of 28 SHCL wearers (Group 1) and 52 eyes of 26 healthy subjects (Group 2) were included in this study’. According to their contact lens wearing time, the contact lens wearing subjects were divided into 2 groups: Group 1a - wearing time less than 1 year and Group 1b - wearing time more than 1 year. CCT, epithelial thickness, corneal endothelial cell morphology, ocular surface disease index score (OSDI), and tear break-up time (TBUT) were evaluated. Re sults: In Group 1 and Group 2, the mean CCT was 561.85±39.98 μm and 537.25±27.12 μm, respectively (p: 0.001).The epithelial thickness was 50.38±5.41 μm and 55.64±5.32 μm, respectively (p: 0.001). In Group 1a and Group1 b, the mean CCT was 573.39±33.86 μm and 546.96±42.98 μm (p: 0.014) and the epithelial thickness was 49.51±4.78 μm and 51.50±6.04 μm (p>0.05), respectively. In Group 1, the percentage of endothelial cells larger than 700μ was low, while the percentage of endothelial cells between 200 and 400μ was high (p

Özet

Amaç: Silikon hidrojel kontakt lenslerin (SHKL); santral kornea kalınlığına (SKK), kornea endotel hücre morfolojisine ve gözyaşı fonksiyonlarına etkilerinin değerlendirilmesi. Ge reç ve Yön tem: Silikon hidrojel kontakt lens kullanan 28 olgunun 55 gözü ile (Grup 1), kontakt lens kullanmayan 26 sağlıklı bireylerin 52 gözü (Grup 2) çalışma kapsamına alındı. Lens kullanan olgular kontakt lens kullanım ’sürelerine göre Grup 1a: 1 yıldan az, Grup 1b: 1 yıldan fazla olmak üzere ikiye ayrıldı. Tüm olgularda SKK ve kornea epitel kalınlığı, kornea endotel hücre morfolojisi, oküler yüzey hastalık indeks skoru (OSDİ) ve gözyaşı kırılma zamanı (GKZ) değerlendirildi. Sonuçlar: Grup 1 ile Grup 2’de ortalama SKK sırasıyla 561,85±39,98 μm; 537,25±27,12 μm(p: 0,001), epitel kalınlığı 50,38±5,41μm, 55,64±5,32 μm bulundu (p: 0,001). Grup 1a ve 1b’de ortalama SKK sırasıyla 573,39±33,86 μm; 546,96±42,98 μm (p: 0,014), epitel kalınlığı 49,51±4,78 μm, 51,50±6,04 μm (p>0,05) idi. Grup 2’ye göre Grup 1’de 700μ’dan büyük endotel hücre yüzdesi daha az, 200-400μ arasındaki endotel hücre yüzdesi fazlaydı ( p

🔖

Cite This Article

Yıldız, Y., CAN, İ., GÜRDAL, C., NACAROĞLU, Ş. A., SARAÇ, Ö., TAKMAZ, T. (2022). The long-term effects of silicone hydrogel contact lens wear on corneal morphology. Türk Oftalmoloji Dergisi, Cilt: 42 - Sayı: 2, 91–96. https://ajindex.com/articles/638231

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Heitz RF. History of contact lenses. CLAO Guide to Basic Science and Clinical Practice. Boston, Little Brown&Co;1984.p.1-19
  2. McMahon TT, Zandik K. Twenty-five years of contact lenses: the impact on the cornea and ophthalmic practice. Cornea. 2000;19:730-40
  3. McCanna DJ, Driot JY, Hartsook R, Ward KW. Rabbit models of contact lens- -associated corneal hypoxia: a review of the literature. Eye Contact Lens. 2008;34:160-5
  4. Bergmanson JP, Chu LW. Corneal response to rigid contact lens wear. Br J Ophthalmol. 1982;66:667-75
  5. Bourne WM, Hodge DO, McLaren JW. Estimation of corneal endothelial pump function in long term contact lens wearers. Invest Ophthalmol Vis Sci. 1999;40:603-11
  6. Dillahay SM. Does the level of available oxygen impact comfort in contact lens wear?: A review of the literature. Eye Contact Lens. 2007;33:148-55
  7. Albertz JM. Conjonktival histologic findings of dry eye and non-dry eye contact lens wearing subject. CLAO J. 2001;27:35-40
  8. Holden B,Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. İnvest Ophthalmol Vis Sci. 1984;25:1161-7
  9. Cox I, Zantos SG, Orsborn G. The overnight corneal swelling response of non-wear and extended wear soft lens patients. Int Contact Lens Clin. 1990;17:134-8
  10. Brien AH, Deborah FS, Anti V, Klas TN, Nathan E. Effects of Long-Term Extended Contact Lens Wear on the Human Cornea. İnvest Ophthalmol Vis Sci. 1985;26:1489-501
  11. Papas E. On the relationship between soft contact lens oxygen transmissiblity and induced limbal hyperaemia. Exp Eye Res. 1998;67:125-31
  12. Papas EB, Vajdic CM, Austen R, Holden BA. High-oxygen-trasnmissibility soft contact lenses do not induce limbal hyperaemia. Curr Eye Res. 1997;16:942-8
  13. Lee JS, Park WS, Lee SH, Oum BS, Cho BM. A comparative study of corneal endothelial Chamges induced by different durations of soft contact lens wear. Graefes Arch Clin Exp Ophthalmol. 2001;239:1-4
  14. Mac Rae SM, Matsuda M, Shellans S, Rich LF. The effects of hard and soft contact lenses on the corneal entothelium. Am J Ophthalmol. 1986;102:50-7
  15. Setala K, Vasara K, Vesti E, Ruusuvaara P. Effects long term contact lens wear on the corneal entothelium. Acta Ophthalmol Scand. 1988;76:299-303
  16. Cavanagh HD, Ladage PM, Li SL, et al. Effects of daily and overnight wear of a novel hyper oxygen-transmissible soft contact lens on bacterial binding and corneal epithelium: a 13-month clinical trial. Ophthalmology. 2002;109:1957-69.