Journals / Türk Anestezi ve Reanimasyon Dergisi / 2003 / Cilt: 31 - Sayı: 6

Difficult tracheal extubation (Case report)

Zor trakeal ekstübasyon (Olgu sunumu)

Pages
309–312
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In patients with difficult tracheal extubation, it is better to do extubation after finding the real reason.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Difficult tracheal extubation is hardly recognized by anesthesiologists as it is rarely encountered in compa-rison to difficult tracheal intubation.
📊
Key Findings & Data:In patients, trials of extubation can be fatal when the real reason is not found.
💡
Conclusion & Impact:In patients with difficult tracheal extubation, it is better to do extubation after finding the real reason.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Difficult tracheal extubation is hardly recognized by anesthesiologists as it is rarely encountered in compa-rison to difficult tracheal intubation. In patients, trials of extubation can be fatal when the real reason is not found. In most cases, the problem arises from an inability to deflate the cuff, commonly as a result of failure in the cuff-deflating mechanism. We present a patient who had operation for laryngo-fissur and chordectomy. The patient was intubated orally by direct laryngoscopy with a spiral endotracheal tube, which was used for the second time due to economical reasons. At the end of operation, the cuff could not be deflated via normal procedure. The patient was given anesthesia again and the cuff was exploded by a stile under direct laryngoscopy and extubation was performed. In patients with difficult tracheal extubation, it is better to do extubation after finding the real reason.

Özet

Zor trakeal ekstübasyon zor trakeal entübasyon kadar sık görülmediği için anestezistler tarafından göreceli daha az tanınır. Bu hastalarda gerçek neden belirlenmeden yapılan ekstübasyon denemeleri ölümcül olabilir. Pek çok olguda bu problem, kaf havasını boşalma mekanizmasının bozulması nedeniyle kafın indirilememesinden kaynaklanır. Biz laringo-fissür ve kordektomi ameliyatı geçiren bir olguyu sunacağız. Olgu ekonomik nedenlerden dolayı ikinci kez kullanılan spiral tüp ile direkt laringoskopi altında orotrakeal entübe edildi. Ameliyat sonunda kafın havası normal işlemlerle indirilemedi. Olguya yeniden anestezi verildi, direkt laringoskopi altında bir stile ile kaf patlatıldı ve ekstübasyon gerçekleştirildi. Zor trakeal ekstübasyon olgularında, asıl nedenin ortaya konduktan sonra ekstübasyonun gerçekleştirilmesi daha iyi olacaktır.

🔖

Cite This Article

EGELİ, E., HÜSEYİNOĞLU, Ü. A., ÇANKAYA, H., DEMİREL, C. B., KATI, İ. (2022). Difficult tracheal extubation (Case report). Türk Anestezi ve Reanimasyon Dergisi, Cilt: 31 - Sayı: 6, 309–312. https://ajindex.com/articles/620260

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Nakagawa H, Komatsu R, Hayashi K, Isa K, Tanaka Y:Fiberoptic evaluation of the difficult extubation. Anesthesiology 1995; 82:785-786, 2. Sprung J, Conley SF, Brown M: Unusual cause of difficult exlubation, Anesthesiology 1991; 74:796-797. 3. Lang S, Johnson DH, Lanigan DT, Ha H: Difficult tracheal extubation. Can J Anaesth 1989; 36:340-342. 4. Bell WH, Sinn DP: Turbinectomy to facilitate superior movement of the maxilla by Le Fort I osteotomy. J Oral Surg 1979; 37:129-130. 5. Hilley MD, Henderson RB, Giesecke AH: Difficult extubation of the trachea. Anesthesiology 1983; 59:149-150. 6. Lee C, Schwartz S, Mok MS: Difficult extubation due to transfixation of a nusotracheal tube by a Kirschner wire. Anesthesiology 1977; 46:427. 7. Schwartz LB, Sordill WC, Liebers RM, Schwab W: Difficulty in removal of accidentally cut endotracheal tube. J Oral Maxillofac Surg 1982; 40:518-519. 8. Dryden GE: Circulatory collapse after pneumonectomy (an unusual complication from the use of a Carlens catheter): case report. Anesth Analg 1977; 56:451-452. 9. Hagbery C, Boin MH: Management of the airway: Complications. In: Benumof JL, Saidman LJ (eds). Anesthesia&Perioperative Complications. St. Louis: Mosby; 1999; 3-24. 10. Tanski J, James RH: Difficult extubation due to a kinked pilot tube. Anaesthesia 1986; 41:1060. 11. Tavakoli M, Corssen G: An unusual case of difficult extubation. Anesthesiology 1976; 45:552-553. 12. Brock-Utne JG, Jaffe RA, Robins B, Ratner E: Difficulty in extubation. A cause for concern. Anaesthesia 1992; 47:229-230. 13. Khan RM, Khan TZ, Ali M, Khan MS: Difficult extubation. Anaesthesia 1988; 43:515. 14. Mishra P, Scott DL: Difficulty at extubation of the trachea. Anaesthesia 1983; 38:811. 15. Ng TY, Datta TD: Difficult extubation of an endotracheal tube cuff, Anesth Analg 1976; 55:876-877. 16. Fagraeus L: Difficult extubation following nasotracheal intubation. Anesthesialogy 1978; 49:43-44. 17. Tashayod M, Oskoui B: A case of difficult extubation. Anesthesialogy 1973; 39:337. 18. Popat MT, Dravid RM, Watt-Smith SR: Use of the flexible intubating fibrescope for tracheal re-intubation in a patient with difficult extubation. Anaesthesia 1999; 54:359-361.