Journals / International Journal of Thermodynamics / 2013 / Cilt: 16 - Sayı: 1

Exergy Analysis of Combined Cycle Power Plant: NTPC Dadri, India

Pages
36–42
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Its reached 35% of the total exergy losses while the exergy losses in other plant components are between 7% -21% of the total exergy losses at 1400o C turbine inlet temperature and pressure ratio 10 .This paper also considered the effect of the pressure ratio, turbine inlet temperature, pressure drop in combustion chamber and heat recovery steam generator on the exergy losses in the plant, there are a clear effects in the exergy losses when changing pressure ratio, turbine inlet temperature.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of the present paper is to exergy analysis of combined Brayton/Rankine power cycle of NTPC Dadri India.
📊
Key Findings & Data:Theoretical exergy analysis is carried out for different components of dadri combined cycle power plant which consists of a gas turbine unit, heat recovery steam generator without extra fuel consumption and steam turbine unit.
💡
Conclusion & Impact:Its reached 35% of the total exergy losses while the exergy losses in other plant components are between 7% -21% of the total exergy losses at 1400o C turbine inlet temperature and pressure ratio 10 .This paper also considered the effect of the pressure ratio, turbine inlet temperature, pressure drop in combustion chamber and heat recovery steam generator on the exergy losses in the plant, there are a clear effects in the exergy losses when changing pressure ratio, turbine inlet temperature.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:2nd Law · Exergy

Abstract

The aim of the present paper is to exergy analysis of combined Brayton/Rankine power cycle of NTPC Dadri India. Theoretical exergy analysis is carried out for different components of dadri combined cycle power plant which consists of a gas turbine unit, heat recovery steam generator without extra fuel consumption and steam turbine unit. The results pinpoint that more exergy losses occurred in the gas turbine combustion chamber. Its reached 35% of the total exergy losses while the exergy losses in other plant components are between 7% -21% of the total exergy losses at 1400o C turbine inlet temperature and pressure ratio 10 .This paper also considered the effect of the pressure ratio, turbine inlet temperature, pressure drop in combustion chamber and heat recovery steam generator on the exergy losses in the plant, there are a clear effects in the exergy losses when changing pressure ratio, turbine inlet temperature.

🔖

Cite This Article

TiWARI, A., HASAN, M., ISLAM, M. (2022). Exergy Analysis of Combined Cycle Power Plant: NTPC Dadri, India. International Journal of Thermodynamics, Cilt: 16 - Sayı: 1, 36–42. https://ajindex.com/articles/541863

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Aljundi, I.H., (2009). Energy and exergy analysis of a steam power plant in Jordan. Applied Thermal Engineering, 29, 324–328.
  2. Bassily, A.M., (2005). Modeling, numerical optimization, and irreversibility reduction of a dual-pressure reheat combined-cycle. Applied Energy, 81, 127–151.
  3. Bejan, A., (2002). Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architecture. Int J Energy Res, 26, 545–565.
  4. Cerri, G. (1987). Parametric analysis of combined gassteam cycles. J. Eng. Gas Turbines Power, 109(1), 46 Czermak, H., & Wansch, A. (1982). The 125 MW combined cycle plant Korneuburg; Design features, plant performance and operation experience. ASME paper 82GT-323. EI-Masri, M.A., (1987). Exergy Analysis of Combined Cycles: Part 1 - Air-Cooled Brayton-Cycle.Gas Turbines. J. Eng. Gas Turbines Power, 109(2), 228-236.
  5. Franco, A., (2011). Analysis of small size combined cycle plants based on the use of supercritical HRSG. Applied Thermal Engineering, 31, 785-794.
  6. Heppenstall, T., (1998). Advanced gas turbine cycles for power generation: a critical review. Applied Thermal Engineering, 18, 837-846.
  7. Horlock, J.H., (1995). Combined power plants-past, present, and future. Journal of engineering for gas turbines and power, 117(4), 608-616.
  8. Ibrahim, T. K., Rahman, M.M, Abdalla, A.N., (2011). Optimum Gas Turbine Configuration for Improving the performance of Combined Cycle Power Plant. Procedia Engineering, 15, 4216 – 4223. Koch, C., Cziesla, F., Tsatsaronis, G., (2007). Optimization of combined cycle power plants using evolutionary algorithms. Chemical Engineering and Processing, 46, 1151–1159.
  9. Manfrida, G., Bosia, A. and Bindini, G., (1988). Second law analysis of combined gas/steam cycles. Proc. 23rd Intersociety energy conversion engineering conference, pp 391-397.
  10. Mansouri, M.T., Ahmadi, P., Kaviri, A.G., Jaafar, M.N.M., (2012). Exergetic and economic evaluation of the effect of HRSG configurations on the performance of combined cycle power plants. Energy Conversion and Management, 58, 47–58.
  11. Nag, P.K. and Raha, D., (1995). Thermodynamic analysis of a coal-based combined cycle power plant. Heat Recovery Systems and CHP, 15(2), 115-129.
  12. Polyzakis, A., (1995). Industrial gas-turbine for combined cycle plant. M.Sc. thesis, Cranfield University, 1995.
  13. Polyzakis, A.L., Koroneos, C., Xydis, G., (2008). Optimum gas turbine cycle for combined cycle power plant. Energy Conversion and Management, 49, 551–563.
  14. Regulagadda, P., Dincer, I., Na