Journals / International Advanced Researches and Engineering Journal / 2018 / Cilt: 2 - Sayı: 3

Seismic performance of steel moment frames with variable friction pendulum systems under real ground motions

Pages
208–216
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed that the isolated frames having greatest radius of curvature with lowest friction coefficient exhibited better seismic performance than other models in terms of the local and global deformations.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Many researchers have already acknowledged that the base isolation system as the most feasible and economical method for civil engineering structures exposed to the seismic excitation.
📊
Key Findings & Data:The response of isolated frames is simply adjusted by several parameters such as the friction coefficient (μ), the radius of curvature (R), the isolation period (T) and the axial load and so 2D, three bay 3 and 7-storey steel moment resisting frames (SMRF) are designated as isolated frames in order to examine the effect of variation of the R and the friction coefficient on the seismic response of the isolated frames.
💡
Conclusion & Impact:The results showed that the isolated frames having greatest radius of curvature with lowest friction coefficient exhibited better seismic performance than other models in terms of the local and global deformations.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Friction pendulum systems · Isolator response model · Seismic isolation

Abstract

Many researchers have already acknowledged that the base isolation system as the most feasible and economical method for civil engineering structures exposed to the seismic excitation. The Friction Pendulum Systems (FPS) have steel concave surface connected with articulated friction slider and utilized the concept of pendulum for lengthening the period of the superstructure so as to dissipate the seismic energy. The present study investigates on various design approaches for the evaluation of the seismic response of steel frames equipped with FPS. The response of isolated frames is simply adjusted by several parameters such as the friction coefficient (μ), the radius of curvature (R), the isolation period (T) and the axial load and so 2D, three bay 3 and 7-storey steel moment resisting frames (SMRF) are designated as isolated frames in order to examine the effect of variation of the R and the friction coefficient on the seismic response of the isolated frames. The R and μ are predefined as 1, 1.55, 2.25 and 0.025, 0.05, 0.1, respectively. The seismic response of the modelled isolation systems has been evaluated through nonlinear time history analyses, a set of ground motions using SAP2000 software. The local and global deformations are employed to compare the seismic performance of different isolation frames through nonlinear analysis. The results showed that the isolated frames having greatest radius of curvature with lowest friction coefficient exhibited better seismic performance than other models in terms of the local and global deformations.

🔖

Cite This Article

DERİNGÖL, A. H. (2022). Seismic performance of steel moment frames with variable friction pendulum systems under real ground motions. International Advanced Researches and Engineering Journal, Cilt: 2 - Sayı: 3, 208–216. https://ajindex.com/articles/539423

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Matsagar, V.A., and R.S., Jangid, Influence of isolator characteristics on the response of base-isolated structures. Engineering Structures, 2004. 266: p. 1735-49
  2. Xu, C., J.G. Chase, and G.W. Rodgers, Physical parameter identification of nonlinear base-isolated buildings using seismic response data. Computers and Structures, 2014. 145: p. 47-57
  3. Alhan, C. and S. Öncü-Davas, Performance limits of seismically isolated buildings under near-field earthquakes. Engineering Structures, 2016. 116: p. 83-94
  4. Cancellara, D. and F.D., Angelis, Assessment and dynamic nonlinear analysis of different base isolation systems for a multi-storey RC building irregular in plan. Computers and Structures, 2017. 180: p. 74-88
  5. Naeim, F. and J.M. Kelly. 1999, Design of Seismic Isolated Structures. John Wiley & Sons, New York, NY, USA, 1st edition
  6. Bhuiyan, A.VR., Y., Okui, H., Mitamura, and, T., Imai, A rheology model of high damping rubber bearings for seismic analysis: Identification of nonlinear viscosity, International Journal of Solids and Structures, 2009. 46: 1778–1792
  7. Landi, L., G. Grazi, P.P., Diotallevi, Comparison of different models for friction pendulum isolators in structures subjected to horizontal and vertical ground motions. Soil Dynamics and Earthquake Engineering, 2016. 81:p. 75-83
  8. Castaldo, P. and M. Ripani, Optimal design of friction pendulum system properties for isolated structures considering different soil conditions. Soil Dynamics and Earthquake Engineering, 2016. 90:p. 74-87
  9. Castaldo, P., B. Palazzo, and P.D., Vecchia, Seismic reliability of base-isolated structures with friction pendulum bearings. Engineering Structures, 2015. 95: p. 80-93
  10. FEMA, NEHRP commentary on the guidelines for the seismic rehabilitation of buildings, 1997, Federal Emergency Management Agency, Report No
  11. Washington, DC
  12. Jangid, R.S., Optimum friction pendulum system for near-fault motions. Engineering Structures, 2005. 27: p. 349-359
  13. M. Ferraioli, M., A. Lavino, and A. Mandara, Behaviour Factor of Code-Designed Steel Moment-Resisting Frames. International Journal of Steel Structures, 2014. 14 (2): p. 243-254
  14. Italian Code NTC08, Norme tecniche per le costruzioni in zone sismiche, 2008. Ministerial Decree D.M. 14.01.08, G.U. No.9-04.02.08 (in Italian)