Journals / International Advanced Researches and Engineering Journal / 2020 / Cilt: 4 - Sayı: 3

Performing reactive power compensation of three-phase induction motor by using parallel active power filter

Pages
239–248
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The proposed hysteresis controller based PAPF filter makes the power factor up to 1 and the reactive power compensation of the three-phase induction motor.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Nowadays, the problem of power quality increases day by day.
📊
Key Findings & Data:Reactive power and harmonic current lead to heat losses and decrease in the efficiency of the transmission lines.
💡
Conclusion & Impact:The proposed hysteresis controller based PAPF filter makes the power factor up to 1 and the reactive power compensation of the three-phase induction motor.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Harmonics · Parallel active power filter · Power factor correction

Abstract

Nowadays, the problem of power quality increases day by day. Harmonic current and reactive power are the important factors disturbing the power quality. The induction motors draw both harmonic current and reactive power from the grid. Reactive power and harmonic current lead to heat losses and decrease in the efficiency of the transmission lines. Passive and active filter applications have been used to solve these problems. There are some disadvantages of passive filters. Large physical dimensions and resonance with load can be shown as examples for these disadvantages. Therefore, the application areas of Active Power Filter (APF) are rapidly developing due to the fact that they can be applied together with harmonic and reactive power compensation as appropriate control methods. This paper proposes a MATLAB/Simulink simulation to perform power factor correction and reactive power compensation of three-phase induction motor by using three-phase Parallel Active Power Filter (PAPF). In order to generate PAPF’s reference currents the Sine Multiplication Technique (SMT) is used. Simulation studies are presented to be able to assess the performances under different motor operating conditions. The proposed hysteresis controller based PAPF filter makes the power factor up to 1 and the reactive power compensation of the three-phase induction motor.

🔖

Cite This Article

KARAMAN, Ö. A., GÜNDOĞDU, A., CEBECİ, M. (2022). Performing reactive power compensation of three-phase induction motor by using parallel active power filter. International Advanced Researches and Engineering Journal, Cilt: 4 - Sayı: 3, 239–248. https://ajindex.com/articles/539326

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Yılmaz, Ö., Aksoy, M., Kesilmiş, Z. Misalignment fault detection by wavelet analysis of vibration signals. International Advanced Researches and Engineering Journal. 2019. 3(3), p.156-163
  2. Gundogdu, A., Dandil, B., Ata, F. Direct Torque Control Based on Hysteresis Controller of Asynchronous Motor. Science and Eng. J of Firat Univ. 2017. 29(1), p.197-205
  3. Ferreira, S.C., Gonzatti, R.B., Pereira, R.R., Silva, C.H., Silva, L. E. B., Torres, L.G. Finite Control Set Model Predictive Control For Dynamic Reactive Power Compensation With Hybrid Active Power Filters. IEEE Trans. On Industrial Electronics. 2018. 65(3),p.2608–2617
  4. Ye, J., Gooi, H.B., Phase Angle Control Based Three-phase DVR with Power Factor Correction at Point of Common Coupling. in Journal of Modern Power Systems and Clean Energy. 2020. 8(1), p. 179-186
  5. Roy, R.B., Cros,J., Basher, E., Akhter, S. Power Compensation by DSTATCOM Plus SCESS. Proceedings of the 2017 4th International Conference on Advances in Electrical Engineering (ICAEE). 2017. 28-30, p.100-108
  6. Wang, Y., Xu, Q., Chen, G. Simplified Multi-Modular Shunt Active Power Filter System and its Modelling. IET Power Electronic, 2015. 8(6), p. 967–976
  7. Cetin, S. Power Factor Corrected and Fully Soft Switched PWM Boost Converter. IEEE Transactions on Industry Applications, 2018. 54(4), p.3508–3517
  8. Badoni, M., Singh, A., Singh, B. Adaptive Recursive Inverse-Based Control Algorithm for Shunt Active Power Filter. IET Power Electronic, 2016. 9(5), p.1053–1064
  9. IEEE Std 519-1992. Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems. IEEE Std, 1993. p.85-87
  10. Carlos, J., Gil, A., Pérez, E., Ariño, C., Beltran, H. Optimization Algorithm for Selective Compensation in a Shunt Active Power Filter. IEEE Transactions On Industrial Electronics, 2015. 62(6), p.3351–3361
  11. Fang, Y., Fei, J., Wang, T. Adaptive Backstepping Fuzzy Neural Controller Based on Fuzzy Sliding Mode of Active Power Filter.2020. doi:10.1109/ACCESS.2020.2995755, IEEE Access
  12. Sanam, J., Panda, A.K., Ganguly, Sanjib. Optimal Phase Angle Injection for Reactive Power Compensation of Distribution Systems with the Allocation of Multiple Distribution STATCOM. Arabian Journal for Science and Engineering, 2017. 42, p.2663–2671
  13. Ferreira, S.C., Gonzatti, R.B., Pereira, R.R., da Silva, C.H., da Silva, L.E.B., Lambert-Torres, G. Finite Control Set Model Predictive Control for Dynamic Reactive Power Compensation With Hybri