Journals / International Advanced Researches and Engineering Journal / 2021 / Cilt: 5 - Sayı: 1

Dose response of gluconic acid doped Fricke gels irradiated with X-rays

Pages
47–52
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The oxidation of iron increases as a result of the interaction with hydrogen peroxide which is the product of the irradiation process and GA, and thus the response of the gel to the irradiation process becomes more effective.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Adjusting the dose of radiation which is received by a cancer patient during radiotherapy is very important.
📊
Key Findings & Data:In this study, 16 different Fricke gels including gluconic acid (GA) were produced.
💡
Conclusion & Impact:The oxidation of iron increases as a result of the interaction with hydrogen peroxide which is the product of the irradiation process and GA, and thus the response of the gel to the irradiation process becomes more effective.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Fricke gels · FT-IR · gluconic acid

Abstract

Adjusting the dose of radiation which is received by a cancer patient during radiotherapy is very important. The use of dosimetric gels to calculate the applied dose distribution three- dimensionally is a current research topic in radiotherapy. In this study, 16 different Fricke gels including gluconic acid (GA) were produced. These gels were irradiated from 0 to 250 cGy with increments of 50 cGy. MR intensity values and images, UV absorbance values and FT-IR spectra of gels were obtained before and after the irradiation process. The UV absorbance and MR intensity values showed a linear increase in relation to the increase in the applied dose and the amount of ferrous sulfate and GA content in the gels. The oxidation of iron increases as a result of the interaction with hydrogen peroxide which is the product of the irradiation process and GA, and thus the response of the gel to the irradiation process becomes more effective.

🔖

Cite This Article

AKTAŞ, S., SAĞSÖZ, M. E., KORKUT, Ö. (2022). Dose response of gluconic acid doped Fricke gels irradiated with X-rays. International Advanced Researches and Engineering Journal, Cilt: 5 - Sayı: 1, 47–52. https://ajindex.com/articles/539293

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Kron, T., Lehmann, J., Greer, P.B., Dosimetry of ionising radiation in modern radiation oncology. Physics in Medicine & Biology, 2016. 61(14): R167
  2. Keal, P., Baldock C., A theoretical study of the radiological properties and water equivalance of Fricke and polymer gels used for radiation dosimetry. Australasian Physical & Engineering Sciences in Medicine, 1999. 22(3): p. 85-91
  3. Gambarini, G., Carrara, M., Marrani, M., Pirola, L., Tomatis, S., Valente, M., Vanossi, E., Optical analysis of gel dosimeters: Comparision of Fricke and normoxic polymer gels. Nuclear Instruments and Methods in Physics Research, 2007. 263: p. 191-195
  4. Galante, A.M.S., Cervantes, H.J., Cavinato, C.C., Campos, L.L., Rabbani, S.R., MRI study of radiation effect on Fricke gel solutions. Radiation Measurement, 2008. 43(2-6): p. 550-553
  5. Ibbott, G.S., Roed, Y,, Lee, H., Alqathami, M,, Wang, J., Pinsky, L., Blencowe, A., Gel dosimetry enables volumetric evaluation of dose distributions from an MR-guided linac. AIP Conference Proceedings, 2016 Jun 17, Article number 040002
  6. Soliman, Y.S., El Gohary, M.I., Abdel Gawad, M.H., Amin, E.A., Desouky, O.S., Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans. Applied Radiation and Isotopes,. 2017. 120: p. 126-132
  7. Aktaş, S,, Korkut, Ö., Sağsöz, M.E., Dosimetric fricke gel systems improved with CaCl2 and gluconic acid. International Advanced Researches and Engineering Journal, 2018, 2(2):143-146
  8. De Deene, Y., Gel – based radiation dosimetry using quantitative MRI., Chapter 9, NMR and MRI of Gels, 2020, Editor: Yves De Deene p. 275-357
  9. Gallo, S., Cremonesia, L., Gambarini G., Ianni L., Lenardi, C., Argentiere, S., Bette, D., Gargano, M., Ludwig, N., Veronese, I. Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques. Sensors and Actuators B, 2018. 272: p. 618-625
  10. Gambarini, G., Veronese, I, Bettinelli, L, Felisi, M., Gargano, M., Ludwig, N., Lenardi, C., Carrara M., Collura G., Gallo S. et al. Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters. Radiation Measurement, 2017. 106: p. 622-627
  11. Babu, S.E.S., Peace, B.S.T, Rafic, K.M, Raj E.W.M, Christopher J.S, Ravindran B.P. Escalation of optical transmittance and determination of diffusion coefficient in low-bloom strength gelatin-based Fricke gel dosimeters. Radiation Physics and Chemistry, 2019. 156: p. 300–306
  12. Abdelgawad, M.H, Soliman, Y.S, ElGohry