Journals / International Advanced Researches and Engineering Journal / 2022 / Cilt: 6 - Sayı: 1

Thermoeconomic analysis of a geothermal and solar assisted combined organic Rankine and absorption cycle

Pages
34–42
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The unit costs of cooling and electricity in the combined system are calculated 0.017 $/kWh and 0.074 $/kWh, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this paper, a geothermal and solar-assisted combined system is designed for the electricity and cooling of residences.
📊
Key Findings & Data:The organic Rankine cycle (ORC) generates power with geothermal water and heat transfer fluid from the absorption cooling cycle.
💡
Conclusion & Impact:The unit costs of cooling and electricity in the combined system are calculated 0.017 $/kWh and 0.074 $/kWh, respectively.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Absorption refrigeration · geothermal energy · organic rankiye cycle

Abstract

In this paper, a geothermal and solar-assisted combined system is designed for the electricity and cooling of residences. The geothermal water from the geothermal resource and the heat transfer fluid heated in the parabolic trough collector is used as the heat source in the absorption cooling system. The organic Rankine cycle (ORC) generates power with geothermal water and heat transfer fluid from the absorption cooling cycle. The produced power is supported to the grid. Engineering Equation Solver (EES) and Aspen Plus program are used for thermodynamic and thermoeconomic analysis of the combined system. In these analyzes, the geothermal and solar energy values of Afyonkarahisar city are considered. Geothermal water at a temperature of 130 ºC and a mass flow rate of 85 kg/s and a solar source at 600 W/m2 radiation is used for the combined system. Parametric studies are performed to demonstrate the way unit electricity and cooling costs change according to the geothermal water temperature and solar radiation. The cooling capacity and the net power output of the system are 2720 kW and 2235 kW, respectively. The unit costs of cooling and electricity in the combined system are calculated 0.017 $/kWh and 0.074 $/kWh, respectively.

🔖

Cite This Article

YILMAZ, C., Şen, O. (2022). Thermoeconomic analysis of a geothermal and solar assisted combined organic Rankine and absorption cycle. International Advanced Researches and Engineering Journal, Cilt: 6 - Sayı: 1, 34–42. https://ajindex.com/articles/539251

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Salehi, S., Yari, M.and Rosen, M. A.,Exergoeconomic comparison of solar-assisted absorption heat pumps, solar heaters and gas boiler systems for district heating in Sarein Town, Iran. Applied Thermal Engineering, 2019. 153: p. 409-425
  2. Rahman, A., Abas, N., Dilshad, S.and Saleem, M. S.,A case study of thermal analysis of a solar assisted absorption air-conditioning system using R-410A for domestic applications. Case Studies in Thermal Engineering, 2021. 26: 101008
  3. Yu, J., Tang, Y. M., Chau, K. Y., Nazar, R., Ali, S., and Iqbal, W.,Role of solar-based renewable energy in mitigating CO2 emissions: Evidence from quantile-on-quantile estimation. Renewable Energy, 2021. 182: p. 216-226
  4. El Haj Assad, M., Sadeghzadeh, M., Ahmadi, M. H., Al‐Shabi, M., Albawab, M., Anvari‐Moghaddam, A. and Bani Hani, E.,Space cooling using geothermal single‐effect water/lithium bromide absorption chiller. Energy Science & Engineering, 2021. 9: p. 1747-1760
  5. Mirzaee, M., Zare, R., Sadeghzadeh, M., Maddah, H., Ahmadi, M. H., Acıkkalp, E. and Chen, L., Thermodynamic analyses of different scenarios in a CCHP system with micro turbine–Absorption chiller, and heat exchanger. Energy Conversion and Management, 2019. 198: 111919
  6. Rahman, A., Abas, N., Dilshad, S. and Saleem, M. S.,A case study of thermal analysis of a solar assisted absorption air-conditioning system using R-410A for domestic applications. Case Studies in Thermal Engineering, 2021. 26: 101008
  7. Gunhan, T., Ekren, O., Demir, V., Hepbasli, A., Erek, A.and Sahin, A. S.,Experimental exergetic performance evaluation of a novel solar assisted LiCl–H2O absorption cooling system. Energy and buildings, 2014. 68: p. 138-146
  8. Zhai, X. Q., Qu, M., Li, Y., Wang, R. Z. A review for research and new design options of solar absorption cooling systems. Renewable and sustainable energy reviews, 2011. 15: p. 4416-4423
  9. Hassan, H. Z., & Mohamad, A. A. A review on solar cold production through absorption technology. Renewable and Sustainable Energy Reviews, 2012. 16: p. 5331-5348
  10. Cabrera, F. J., Fernández-García, A., Silva, R. M. P., & Pérez-García, M. Use of parabolic trough solar collectors for solar refrigeration and air-conditioning applications. Renewable and sustainable energy reviews, 2013. 20: p. 103-118
  11. Bellos, E., Tzivanidis, C. and Antonopoulos, K. A., Exergetic, energetic and financial evaluation of a solar driven absorption cooling system with various collector types. Applied Thermal Engineerin