Journals / Hittite Journal of Science and Engineering / 2021 / Cilt: 8 - Sayı: 3

Influence of Stem-cell Size and Culture Media Flowing Modality on Cell’s Fate within a Microchannel; a Numerical Analysis

Pages
241–246
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results of this study shed more light on the regulation and control of dynamic cell culture parameters.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The dynamic cell culture process has been widely used in tissue engineering.
📊
Key Findings & Data:Three factors of cell size, fluid flow rate and fluid viscosity were investigated on their sedimentation rate before reaching the microchannel outlet.
💡
Conclusion & Impact:The results of this study shed more light on the regulation and control of dynamic cell culture parameters.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Microchannel · Cell Culture · Stem-cells

Abstract

The dynamic cell culture process has been widely used in tissue engineering. The success of cell culture is influenced by many factors, one of which is how the cells are transferred from the bioreactor to the scaffolds through microchannels. The risk that can reduce the success of the cell culture process is that the cells do not reach the final destination correctly. In this study, the movement of stem cells through a microchannel was theoretically analysed using discrete phase computational fluid dynamics. Three factors of cell size, fluid flow rate and fluid viscosity were investigated on their sedimentation rate before reaching the microchannel outlet. Considering four sizes of 10, 15, 20 and 30 µm for cells, four flow rates of 20, 50, 90 and 180 µl/min in addition, four viscosities of 0.001, 0.005, 0.01 and 0.025 Pa.s were selected for culture media left us a total number of 64 models. The results of the analysis showed that cells with smaller size have a better chance of reaching the microchannel outlet and larger cells are more likely to sediment. Also, higher flow velocities as well as higher fluid viscosity delivering more cells to the destination. The results of this study shed more light on the regulation and control of dynamic cell culture parameters.

🔖

Cite This Article

Ali, D. (2022). Influence of Stem-cell Size and Culture Media Flowing Modality on Cell’s Fate within a Microchannel; a Numerical Analysis. Hittite Journal of Science and Engineering, Cilt: 8 - Sayı: 3, 241–246. https://ajindex.com/articles/537900

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Wiriyasart, S., C. Hommalee, and P. Naphon, Thermal cooling enhancement of dual processors computer with thermoelectric air cooler module. Case Studies in Thermal Engineering, 2019. 14: p. 100445. Jayamohan, H., et al., Chapter 11 - Advances in Microfluidics and Lab-on-a-Chip Technologies, in Molecular Diagnostics (Third Edition), G.P. Patrinos, Editor. 2017, Academic Press. p. 197-217.
  2. Andrade, J.R., E. Kussul, and T. Baydyk, Microchannel filter for air purification. Open Physics, 2020. 18: p. 241 - 254. Abdollahi, A., et al., Fluid flow and heat transfer of nanofluids in microchannel heat sink with V-type inlet/outlet arrangement. Alexandria Engineering Journal, 2017. 56(1): p. 161-170.
  3. Narayanamurthy, V., et al., Microfluidic hydrodynamic trapping for single cell analysis: mechanisms, methods and applications. Analytical Methods, 2017. 9(25): p. 3751-3772. David J. Beebe, a. Glennys A. Mensing, and G.M. Walker, Physics and Applications of Microfluidics in Biology. Annual Review of Biomedical Engineering, 2002. 4(1): p. 261-286.
  4. Moghadas, H., et al., Challenge in particle delivery to cells in a microfluidic device. Drug delivery and translational research, 2018. 8(3): p. 830-842.
  5. Morini, G.L., Single-phase convective heat transfer in microchannels: a review of experimental results. International Journal of Thermal Sciences, 2004. 43(7): p. 631-651.
  6. Hetsroni, G., et al., Fluid flow in micro-channels. International Journal of Heat and Mass Transfer, 2005. 48(10): p. 1982-1998.
  7. Jin, Y., et al., Scale and size effects on fluid flow through self-affine rough fractures. International Journal of Heat and Mass Transfer, 2017. 105: p. 443-451.
  8. Cui, J. and Y.Y. Cui, Effects of Surface Wettability and Roughness on the Heat Transfer Performance of Fluid Flowing through Microchannels. Energies, 2015. 8(6): p. 5704-5724.
  9. Dai, B.M., M.X. Li, and Y.T. Ma, Effect of surface roughness on liquid friction and transition characteristics in micro- and mini-channels. Applied Thermal Engineering, 2014. 67(1-2): p. 283-293.
  10. Wyma, A., et al., Non-Newtonian rheology in suspension cell cultures significantly impacts bioreactor shear stress quantification. Biotechnology and Bioengineering, 2018. 115(8): p. 2101-2113.
  11. Li, X., et al., In Vitro Recapitulation of Functional Microvessels for the Study of Endothelial Shear Response, Nitric Oxide and [Ca2+]i. PLOS ONE, 2015. 10(5): p. e0126797. Tehranirokh, M., et al., Microfluidic devices for cell cultivation and proliferation. Biomicrofl