Journals / Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi / 2007 / Cilt: 22 - Sayı: 1

The design of 4 channel biotelemetry device

4 kanallı biyotelemetri cihazı tasarımı

Pages
7–12
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

So, four different signals at the 9,6Kps data rate were sent to 50-70m distance at the same time without loss.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a four channel biotelemetry device was designed to transmit the measured physiological signals which are ECG, EMG, heart rate, respiratory rate and body temperature.
📊
Key Findings & Data:A 433MHz, 10mW FM/FSK repeater system was used within the system.
💡
Conclusion & Impact:So, four different signals at the 9,6Kps data rate were sent to 50-70m distance at the same time without loss.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, a four channel biotelemetry device was designed to transmit the measured physiological signals which are ECG, EMG, heart rate, respiratory rate and body temperature. These signals were multiplexed with TDM technique and transmitted. A 433MHz, 10mW FM/FSK repeater system was used within the system. So, four different signals at the 9,6Kps data rate were sent to 50-70m distance at the same time without loss.

Özet

Bu çalışmada, hastadan alınan EKG, EMG, kalp atım hızı, solunum hızı, vücut sıcaklığı gibi fizyolojik verilerin ölçümü ve aynı anda 4 farklı ölçüm sonucunun 50-70m uzaklığa iletilebilmesini sağlayan 4 kanallı biyotelemetri cihazının tasarımı gerçekleştirilmiştir. Ölçülen fizyolojik işaretler zaman bölmeli çoğullama tekniğiyle çoğullanıp,bina içerisine yerleştirilen 433.4MHz 10mW’lık FM/FSK tekrarlayıcı sistem ile iletim sağlanmıştır. Sonuç olarak 4 faklı ölçüm işareti 9,6Kps hızında 50-70m uzaklığa kayıpsız iletilmiştir.

🔖

Cite This Article

FİDAN, U., GÜLER, N. F. (2022). The design of 4 channel biotelemetry device. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 22 - Sayı: 1, 7–12. https://ajindex.com/articles/524016

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Garshnek V. and Burkle F. M., “Applications of Telecommunications to Disaster Medicine”, Journal of the American Medical Informatics Association, Vol:6, No:1, 26-37, Jan / Feb 1999. 2. Yılmaz E., “Uzayda Olsanız da Sağlınız Denetim Altında”, Bilim Teknik Dergisi, No:376, 50-53,Mart 1999. 3. M.D. Melnyk, J.M. Silberman, A Wireless Electro-cardiogram System, Yüksek Lisans Tezi, Cornell University, May 2004. 4. Thaddeus R. F. Fulford-Jones, G. Wei, M. Welsh, “A Portable, Low-Power, Wireless Two-Lead EKG System”, Proceedings of the 26th Annual Inter-national Conference of the IEEE EMBS San Francisco, CA, USA, September 1-5, 2004. 5. Filho P.B., Azevedo F.M., “Proposal of a Telemetry System for Bioelectrical Signals Monitoring”, XV Congreso Anual de la Sociedad Española de Ingenieria Biomédica, Valência, Espanha,, 140-143, 27-28 November 1997. 6. Bai J., Hu B., “A Communication Server for Telemedicine Applications” IEEE Transactions on Information Technology in Biomedicine,Vol:1, No:3, 205-209 September 1997. 7. Ackerman M., Craft R., “Telemedicine Technology”,Telemedicine Journal and E-Health, Vol:8,No:1, September 2002 8. Karagozoglu B., “A Multichannel Biotelemetry System”, IEEE, International Biomedical Engineering Days, 64-69, 1992. 9. Mohseni P., Nagarajan K., “An Ultralight Bio-telemetry Backpack for Recording Emg Signals in Moths”, IEEE Transactions on Biomedical Engineering, Vol:48, No:6, 734-737, June 2001. 10. Dobrev D., “Two-Electrode Low Supply Voltage Electrocardiogram Signal Amplifier”, Med. Biol.Eng. Comput., Vol: 42, 272-276, 2004. 11. Güler N.F., Übeyli E.D., “Theory and Applications of Biotelemetry”, Journal of Medical Systems,Vol: 26, No: 2, 159-178, April 2002. 12. Lozano A., The Measurement, Instrumentation and Sensors Handbook, Pages:87.1 - 87.17,CRC Press,