Journals / Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi / 2013 / Cilt: 28 - Sayı: 4

DAMPING PERFORMANCE OF CARBONYL IRON AND MAGNETITE-BASED MAGNETORHEOLOGICAL FLUIDS AND USAGE OF FUMED SILICA AS AN ADDITIVE

KARBONİL DEMİR VE MANYETİT ESASLI MANYETOREOLOJİK SIVILARIN SÖNÜMLEME PERFORMANSI VE KATKI MADDESİ OLARAK SİLİKA DUMANI KULLANIMI

Pages
695–703
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed that when the current is increased up to 2 amps, the damping force is increased by 40% for the MR fluid containing 40% carbonyl iron and 2% fumed silica by mass.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Magnetorheological (MR) fluids are magnetic field dependent fluids used in the semi-active damping systems.
📊
Key Findings & Data:Performance of the MR fluids was tested by using the prototype of MR damper designed and manufactured in accordance with the dimensions of a passenger car s shock absorber.
💡
Conclusion & Impact:The results showed that when the current is increased up to 2 amps, the damping force is increased by 40% for the MR fluid containing 40% carbonyl iron and 2% fumed silica by mass.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Magnetorheological (MR) fluids are magnetic field dependent fluids used in the semi-active damping systems. MR fluids usually consist of magnetic particles dispersed in a carrier liquid. In this work, five different carbonyl iron and magnetite-based MR fluids were prepared with various iron concentrations in silicone oil. The fumed silica was used as an additive to reduce sedimentation of the carbonyl iron particles. Performance of the MR fluids was tested by using the prototype of MR damper designed and manufactured in accordance with the dimensions of a passenger car s shock absorber. Sedimentation stability which affects the performance of the MR fluids was also observed. The effects of particle type, concentration and fumed silica on the damping performance of the MR fluids were evaluated. The results showed that when the current is increased up to 2 amps, the damping force is increased by 40% for the MR fluid containing 40% carbonyl iron and 2% fumed silica by mass.

Özet

Manyetoreolojik (MR) sıvılar yarı-aktif sönümleme sistemlerinde kullanılan manyetik alan bağımlı sıvılardır. MR sıvılar genellikle taşıyıcı bir sıvı içerisinde dağılmış manyetik parçacıklardan oluşmaktadır. Bu çalışmada, karbonil demir ve manyetit esaslı beş farklı MR sıvı, çeşitli demir konsantrasyonları ile silikon yağı içerisinde hazırlanmıştır. Karbonil demir parçacıklarının çökelmesini azaltmak için katkı maddesi olarak silika dumanı kullanılmıştır. MR sıvıların performansı, bir binek araç amortisörünün boyutlarına uygun olarak tasarlanıp üretilen MR amortisör prototipi kullanılarak test edilmiştir. MR sıvıların performansını etkileyen çökelme kararlılığı da gözlenmiştir. Parçacık türünün, konsantrasyonun ve silika dumanının MR sıvıların sönümleme performansı üzerindeki etkileri değerlendirilmiştir. Sonuçlar; akım 2Ae kadar arttırıldığında kütlesel olarak %40 karbonil demir ve %2 silika dumanı içeren MR sıvı için sönümleme kuvvetinin %40a kadar arttığını göstermiştir.

🔖

Cite This Article

ALTIPARMAK, D., ERGİN, T. (2022). DAMPING PERFORMANCE OF CARBONYL IRON AND MAGNETITE-BASED MAGNETORHEOLOGICAL FLUIDS AND USAGE OF FUMED SILICA AS AN ADDITIVE. Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi, Cilt: 28 - Sayı: 4, 695–703. https://ajindex.com/articles/523736

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Chin, B.D., Park, J.H., Kwon, M.H., Park, O.O, “Rheological Properties and Dispersion Stability of Magnetorheological (MR) Suspensions”, Rheologica Acta,Cilt 40, 211-219, 2001
  2. Genç, S., Phulé, P.P., “Rheological Properties of Magnetorheological Fluids”, Smart Mater. Struct., Cilt 11, 140-146, 2002
  3. Klingenberg, D.J., “Magnetorheology: Applications and Challenges”, AIChE Journal, Cilt 47, No.2, 246-249, 2001
  4. Nguyen, Q.H., Choi, S.B., “Optimal Design of MR Shock Absorber and Application to Vehicle Suspension”, Smart Mater. Struct., Cilt 18, 1- 11, 2009
  5. Park, E.J., Luz, L.F., Suleman, A., “Multidisciplinary Design Optimization of An Automotive Magnetorheological Brake Design”, Computers and Structures, Cilt 86, 207-216, 2008
  6. Kieburg, C., Oetter, G., Lochtman, R., Gabriel, C., Laun, H.M., Pfister, J., “High Performance Magnetorheological Fluids Tailored for A 700 Nm Automotive 4-Wheel-Drive Clutch”, The 10th International Conference on Electrorheological Fluids and Magnetorheological Suspensions, University of Nevada, ABD, 101-107, 18-22 Haziran 2006
  7. Yao, H.J., Fu, J., Yu, M., Peng, Y.X., “SemiActive H∞ Control of Seat Suspension With MR Damper”, The 13th International Conference on Electrorheological Fluids and Magnetorheological Suspensions, Journal of Physics: Conference Series, Cilt 412, 1-16, 2013
  8. Barber, D.E., Carlson, J.D., “Performance Characteristics of Prototype MR Engine Mounts Containing LORD Glycol MR Fluids”, The 11th International Conference on Electrorheological Fluids and Magnetorheological Suspensions, Journal of Physics: Conference Series, Cilt 149, 1-4, 2009
  9. Huang, H., Sun, L., Jiang, X., “Vibration Mitigation of Stay Cable Using Optimally Tuned MR Damper”, Smart Structures and Systems, Cilt 9, No.1, 35-53, 2012
  10. Xu, Z.D., Sha, L.F., Zhang, X.C., Ye, H.H., “Design, Performance Test and Analysis on Magnetorheological Damper for Earthquake Mitigation”, Structural Control and Health Monitoring, Published online in Wiley Online Library (wileyonlinelibrary.com), 2012
  11. Gudmundsson, K.H., Jonsdottir, F., Thorstiensson, F., “A Geometrical Optimization of A Magneto-Rheological Rotary Brake in A Prosthetic Knee”, Smart Mater. Struct., Cilt 19, 1-11, 2010
  12. Avraam, M.T., MR-Fluid Brake Design and Its Application to A Portable Muscular Rehabilitation Device, Doktora Tezi, Université Libre De Bruxelles, Faculté De Sciences Appliquées, 2009
  13. Kordonski, W., Golini, D., “Progress Update in Magnetorheological